Manual · Intermec
TRAKKER Antares 248X Stationary Terminal Getting Started Guide
Manual24 pagesPDF 684 KB
Getting started guide for the Intermec TRAKKER Antares 248X stationary terminals (T2480, T2481, T2485, T2486): install, connect, configure.
Covers · 4 models
The models it covers
Intermec 2480Stationary data collection terminal for data entry from$1,275.003 in stock
Intermec 2481Stationary data collection terminal for data entry Call for availability
Intermec 2485Stationary data collection terminal for data entry Call for availability Summary
What is in it
The getting started guide for the Intermec TRAKKER Antares 248X fixed-position data collection terminals: the T2480, T2481, T2485 and T2486. It lists standard and optional features, what ships in the box, the back panel connectors, attaching the antenna, desk and wall mounting, connecting power, scanners and the backup battery, serial, Ethernet and 2.4 GHz RF network connections, the menu system, keypad and status lights, application development and specifications.
Its parts
- Introduction
- T248X Stationary Terminal Features
- Unpacking the Terminal
- Installing and Configuring the Terminal
- Using the Menu System to Configure the Terminal
- Using the Keypad
- Using the Status Lights
- Developing Applications for the Terminal
- Specifications
- Where to Find More Information
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Intermec's getting started guide (P/N 066961-002, 1998) for the TRAKKER Antares 248X stationary terminals: the T2480, T2481, T2485 and T2486. It explains the back panel connectors, mounting, power and backup battery, serial, Ethernet and 2.4 GHz RF connections, the menu system, keypad and status lights, and lists the specifications.
- Device
- Fixed-position programmable data collection terminal for client/server applications or terminal emulation p. 5
- Standard ports
- COM1 RS-232 (9-pin); 6-pin badge scanner connector; Stewart 10-pin external scanner connector p. 10, 11, 16
- Power
- External 12V power supply, rated S 12V, 750 mA; supply input 95 to 250 VAC, 50 to 60 Hz, 125 mA p. 10, 24
- Display
- T2480 and T2485: 4 line by 40 character; T2481 and T2486: 12 line by 40 character, configurable up to 25 lines p. 6
- Memory
- 2MB flash, 750K available; 1MB battery-backed RAM, 512K available; options: 2MB more flash, 2MB or 4MB SRAM drive p. 24
- Network options
- T2485 and T2486: 2.4 GHz RF with UDP Plus or TCP/IP; T2480 and T2481: optional 10BaseT Ethernet p. 5, 19
- Enhanced I/O option
- COM2 RS-232/422/485 or CrossBar multi-drop (25-pin); COM4 RS-232 with adapter cable Part No. 067185; four sense inputs, four output relays, external speaker p. 5, 11, 16
- Input devices
- Intermec 126X, 127X, 128X wands; 1354, 1355 badge scanners; 1516, 1517, 1518, 1519, 1545, 1550A, 1551A laser scanners; 1463 CCD scanner p. 11
- Backup battery
- Rechargeable NiCad 700 mA battery pack for memory and clock; 24 hours for a full charge p. 15, 24
- Size and weight
- Length 10.7 in (27.2 cm), 11.3 in (28.7 cm) with badge scanner; height 9.6 in (24.4 cm); depth 3.9 in (9.9 cm); 9.5 lbs (4.3 kg) p. 24
- Temperature
- Operating -4°F to +122°F (-20°C to +50°C); battery charging +32°F to +104°F (0°C to +40°C) p. 24
- Mounting brackets
- Desk-Mount Bracket Part No. 066709; Wall-Mount Bracket Part No. 066708 p. 12
- Keypad and badge scanner
- Alphanumeric (PC-style) or oversized function numeric keypad; optional visible or infrared badge scanner p. 6
- Development tools
- TRAKKER Antares Programmer's Software Kit Part No. 065332; EZBuilder Part No. 066381 p. 23
What this manual walks you through
- Attaching the antenna on a T2485 or T2486 p. 12
- Mounting in the desk-mount or wall-mount bracket p. 12, 13
- Removing the back panel and connecting power and input devices p. 14, 15
- Charging the backup battery p. 15
- Connecting and configuring the COM1, COM2 and COM4 serial ports p. 16, 17
- Setting up COM2 on an Intermec CrossBar network p. 17, 18
- Connecting a T2480 or T2481 to Ethernet p. 18, 19
- Configuring a T2485 or T2486 for a 2.4 GHz RF network p. 19, 20
- Using the TRAKKER Antares 2400 Menu System p. 21
- Using the color-coded keypad and status lights p. 22, 23
Good to know
- Keep all components with antennas at least 1 foot (0.3 meters) apart when powered. p. 12
- Without the Intermec desk or wall-mount bracket, the power supply is for indoor use only; the manual states IEC 60529/IP53 protection applies only when properly installed in one. p. 13
- Tighten the six back panel screws to 19 in-lb torque. p. 16
- The 1464 CCD scanner can be used only when nothing is on the badge scanner connector. p. 11
- Outside North America a power cord for the power supply must be bought separately. p. 7
Questions this manual answers
What power does the Intermec TRAKKER Antares 2480 need?
An external 12V power supply (rating S 12V, 750 mA); the supply runs on 95 to 250 VAC, 50 to 60 Hz. p. 10, 24
Which scanners can connect to the Intermec 248X terminal?
Through the Stewart 10-pin connector: Intermec 126X, 127X and 128X wands, 1354 and 1355 badge scanners, 1516 to 1519, 1545, 1550A and 1551A lasers, 1550B and 1551B at stated software levels, and the 1463 CCD scanner. p. 11
How long does the 248X backup battery take to charge?
24 hours with the power supply connected. p. 15
What are the part numbers of the 2480 desk and wall brackets?
Desk-Mount Bracket Part No. 066709 and Wall-Mount Bracket Part No. 066708. p. 12
Which TRAKKER Antares 248X models have radio?
The T2485 and T2486, on a 2.4 GHz RF network; the T2480 and T2481 can have a 10BaseT Ethernet option instead. p. 5
The whole text · 3 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file







