Page 9

nugget c o d e Installing 39 and Configuring the Terminal

To install your T248X 1. Attach the antenna on a T2485 or T2486. See page 12. 2. If you have a wall-mount bracket, install it and install the terminal in the wall-mount bracket. See page 12. 3. Connect the power supply and input devices to the T248X. See page 14. 4. Charge the backup battery. See page 15. 5. Connect the T248X to serial devices or networks. See page 16. 6. Connect the T2480 or T2481 directly to an Ethernet network. See page 18. 7. Connect the T2485 or T2486 to an RF network. See page 19. 8. If you have a desk-mount bracket, install it and install the terminal in the desk-mount bracket. See page 12. Before you get started, use the next section to learn about the connectors and components inside the rear enclosure of the terminal.

9

Page 10

TRAKKER Antares 248X Getting Started Guide nugget c o d e 39

Understanding the Back Panel To install the T248X, you must remove the back panel to connect power, input devices, and communications ports. The next illustration shows all the connectors on a T2480 or T2481 that has an enhanced input/output board and the Ethernet option.

9

1 2

3 4

8

248XG.025

7

6

5

Each feature on the back panel is defined next.

10

1

Terminal block connectors The terminal blocks (shipped with the terminal) let you connect four sense inputs, four output relays, and an amplified external speaker to the terminal. You use the sense inputs to monitor events, such as the opening or closing of a door. You use the output relays to actuate external devices, such as a door lock. The terminal block connectors are only available on a T248X with the option for the enhanced input/output board.

2

12V power supply connector The terminal operates using an external power supply. It has a backup battery that is designed to back up all memory and the real-time clock only in case of a power failure. You must have a power supply connected to operate the terminal.

3

Badge scanner (6-pin) connector You can order the terminal with an integrated badge scanner already installed, or order the badge scanner accessory to install at a later date. You can also attach an input device instead of the badge scanner.

Page 11

nugget

4 c o d e Installing 39 and Configuring the Terminal

External scanner (Stewart 10-pin) connector You must use an interface cable to connect an input device to the terminal. You can attach these input devices: •

Intermec 126X, 127X, and 128X wands

•

Intermec 1354 and 1355 badge scanners

•

Intermec 1516, 1517, 1518, 1519, and 1545 laser scanners

•

Intermec 1550A and 1551A laser scanners

•

Intermec 1550B laser scanner with software revision 1.9 or later

•

Intermec 1551B laser scanner with software revision 1.1 or later

•

Intermec 1463 CCD scanner Note: If you have a device installed on the badge scanner connector, you must configure the 1463 Trigger mode to either Manual Trigger or Auto-Trigger.

Intermec is always testing and developing new input devices. For an updated list of Intermec-approved input devices for the T248X, see your Intermec sales representative. Note: You can use the 1464 CCD scanner only if you do not have a device installed on the badge scanner connector. 5

Cable restraint You use the cable restraint to secure the power supply cable, the terminal block wires, and the Ethernet cable.

6

Ethernet connector The 10BaseT Ethernet connector lets you connect the T2480 or T2481 directly to an Ethernet network.

7

COM1 You can communicate with other RS-232 devices, such as PCs and printers, through the COM1 serial port.

8

COM2

You can use the COM2 serial port for:

•

RS-232, RS-422, or RS-485 serial communications

•

Multi-Drop (CrossBar) network connectivity

COM2 is only available on a T248X with the option for the enhanced input/output board. 9

COM4 You can attach an adapter cable accessory (Part No. 067185) to the 10-pin COM4 connector to use an additional serial port for RS-232 serial communications. For help ordering the adapter cable, contact your local Intermec service representative. COM4 is only available on a T248X with the option for the enhanced input/output board.

11

Page 12

TRAKKER Antares 248X Getting Started Guide nugget c o d e 39

Attaching the Antenna On the T2485 and T2486, the antenna is shipped separately. Remove the antenna from the shipping box and attach the antenna as shown. Choose a location for the terminal where the antenna can be effective. Do not place the terminal where the antenna is too close to a metal wall or it will limit the communications range. Caution Make sure all components with antennas are at least 1 foot (0.3 meters) apart when power is applied. Failure to comply could result in equipment damage.

248XG.011

Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d’au moins un pied (0.3 mètres) avant de faire la connexion avec l’alimentation électrique, faute de quoi vous risquez d’endommager votre installation.

Using the Desk-Mount or Wall-Mount Bracket There are two accessories to help you mount the terminal: •

TRAKKER Antares 248X Desk-Mount Bracket (Part No. 066709)

•

TRAKKER Antares 248X Wall-Mount Bracket (Part No. 066708)

To install the desk-mount bracket 1. Connect power and all other devices through the back panel of the terminal. 2. Install the desk-mount bracket and the terminal. For help, see the accessory instruction sheet.

Desk-mount bracket

12

Page 13

nugget c o d e Installing 39 and Configuring the Terminal

To install the wall-mount bracket 1. Install the wall-mount bracket and the terminal. For help, see the accessory instruction sheet. 2. Connect power and all other devices through the back panel of the terminal. To mount the power supply •

The T248X and the power supply are dust and moisture protected to IEC 60529/IP53 only when installed properly in the Intermec deskmount or wall-mount bracket. The brackets use a power supply holder to effectively protect the power supply from dust and moisture. For help, see the accessory instruction sheets.

248XG.021

Wall-mount bracket

Intermec recommends that you use the desk or wall-mount bracket to mount the T248X and protect the power supply. You can use other mounting brackets or enclosures. However, without the Intermec desk or wall-mount bracket, the power supply is intended for indoor use only. Use of any other mounting brackets or enclosures will void the environmental protection ratings of the terminal. Warning Installation of the power supply must be performed strictly in accordance with the procedures contained in the TRAKKER Antares 248X desk and wall-mount bracket instruction sheets. Failure to protect the power supply in areas of high dust and moisture may result in injury or death due to electric shock. Avertissement L’installation de la source d’alimentation doit être exécutée en respectant de façon stricte les procédures décrites dans les feuilles d’instruction du TRAKKER Antares 248X de bureau et monté au mur. L’échec de la protection de la source d’alimentation dans des zones de grande poussière et d’humidité peut entraîner des blessures ou la mort en raison d’un choc électrique.

13

Page 14

TRAKKER Antares 248X Getting Started Guide nugget c o d e 39

Connecting Power and Input Devices You connect power and input devices through the rear enclosure of the TRAKKER Antares 248X terminal. To connect the power supply and input devices 1. Use a Phillips screwdriver to remove the six screws on the back panel.

Screw (6 places)

248XG.005

Back panel

2. Remove the back panel and place it on a clean surface. 3. Connect the power supply and input devices to the back of the terminal.

14

•

Connect the power supply plug to the 12V power supply connector. Next, connect the power cord from the power supply to a powered electrical outlet.

•

Connect the badge scanner 6-pin connector to the badge scanner connector.

•

Connect the Stewart 10-pin connector from the input device to the external scanner connector.

Page 15

nugget c o d e Installing 39 and Configuring the Terminal

Connecting the Power Supply and Input Devices External scanner connector

Badge scanner connector

12V power supply connector

12V power supply plug Cable restraint 248XG.035

Cable restraint bar To power Scissors supply seal

4. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the power supply cable under the cable restraint. Tighten the screw to secure the cable. 5. Route all the cables under the cable restraint bar and through the scissors seal. 6. Leave the back panel off and continue with the instructions to connect other network devices.

Charging the Backup Battery The backup battery backs up all memory and the real-time clock in case of a power failure. The backup battery is shipped inside the terminal, but may not be fully charged. You need to fully charge the backup battery after you install the terminal. To charge the backup battery 1. Make sure the power supply is connected to the terminal and a powered electrical outlet. 2. Let the power supply charge the backup battery for 24 hours to fully charge the backup battery.

15

Page 16

TRAKKER Antares 248X Getting Started Guide nugget c o d e 39

Connecting to Serial Devices and Networks You use the terminal’s serial ports to transfer data between the terminal and a serial device. Every T248X has one serial port (COM1) that supports RS-232 communications. You can use COM1 to connect to a serial device, such as a printer, scale, or PC. The terminal has an option for an enhanced input/output board that provides two additional serial ports. COM2 supports RS-232/422/485 communications. You can use COM2 to connect to a serial device, a wired network, or an Intermec CrossBar network. COM4 supports RS-232 communications. You need the adapter cable accessory (Part No. 067185) to use COM4. To connect the COM ports 1. Connect the 9-pin RS-232 connector from a serial device to the COM1 connector on the back of the terminal.

COM4

COM1

248XG.036

COM2

To device

2. Connect the 25-pin serial or multi-drop connector from a serial device or network to the COM2 connector on the back of the terminal. 3. Connect the 9-pin RS-232 connector from a serial device to the COM4 adapter cable on the back of the terminal. 4. Route the cables under the cable restraint bar and through the scissors seal. 5. With the seal facing toward the terminal, place the back panel on the back of the terminal. 6. Use a Phillips screwdriver to tighten the six screws to 19 in-lb torque.

16