The text of a manual · part 3 of 3

TRAKKER Antares 248X Stationary Terminal Getting Started Guide, pages 17 to 24

Pages 17 to 24 of 24

The original document is the PDF (684 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2480, Intermec 2486, Intermec 2481 and Intermec 2485

Page 17

nugget

7. Press the c o d e Installing 39 and Configuring the Terminal f key on the keypad. The Boot Menu appears.

Note: If the backup battery charge is low, you may need to press information screen.

] to exit a battery to boot the terminal and initialize the firmware. The TRAKKER 8. Press Antares screen appears. Next, either a sample application screen or a terminal emulation (TE) application welcome screen appears. Note: On a T248X loaded with terminal emulation, you may need to press create the TE configuration file.

to

9. Configure COM1, COM2, or COM4 using the next instructions. To configure COM1, COM2, or COM4 to communicate with serial devices 1. Use the TRAKKER Antares 2400 Menu System to set these COM1, COM2, or COM4 serial port parameters: •

Time and date

•

Protocol (default is Configurable)

•

Baud rate

•

Optional parameters (depending on the protocol): Parity, Data bits, Stop bits, Flow control, EOM, SOM, LRC, Handshake, and Commands Via Serial Port

For help, see “Using the Menu System to Configure the Terminal” later in this guide. Note: For COM4, the Scanner Port field is only used on the TRAKKER Antares 242X hand-held terminals. For the T248X, the Scanner Port field (if shown) is ignored. 2. Configure the serial port parameters for the serial device (for example, a PC) to which you are connecting the terminal. The values you set for the terminal’s serial port must match the values set for the device’s serial port. To configure COM2 to communicate in an Intermec CrossBar network 1. Use the TRAKKER Antares 2400 Menu System to set these COM2 serial port parameters: •

Time and date

•

Protocol = Multi-Drop

•

Baud rate

•

Multi-Drop address

17

Page 18

TRAKKER Antares 248X Getting Started Guide nugget c o d e 39

For help, see “Using the Menu System to Configure the Terminal” later in this guide. 2. Configure your 9154 or 9161 controller to add the new multi-drop T248X device. For help, see your controller user’s manual.

Connecting Directly to an Ethernet Network The TRAKKER Antares 2480 and 2481 terminals have an option for an Ethernet (10BaseT) card. With this option, your terminal can communicate to a host or any device on an Ethernet network. To connect to an Ethernet network 1. Configure your host computer and network. Assign an IP address for the T2480 or T2481. 2. Connect the Ethernet jack to the Ethernet connector on the back of the terminal.

Ethernet connector

248XG.038

To Ethernet network

3. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the Ethernet cable under the cable restraint. Tighten the screw to secure the cable. 4. Route the cable under the cable restraint bar and through the scissors seal. 5. With the seal facing toward the terminal, place the back panel on the back of the terminal. 6. Use a Phillips screwdriver to tighten the six screws to 19 in-lb torque.

18

Page 19

nugget c o d e Installing 39 and Configuring the Terminal

7. Plug the other end of the Ethernet cable into an Ethernet jack on your network. 8. Press the f key on the keypad. The Boot Menu appears.

Note: If the backup battery charge is low, you may need to press information screen.

] to exit a battery to boot the terminal and initialize the firmware. The TRAKKER 9. Press Antares screen appears. Next, either a sample application screen or a terminal emulation (TE) application welcome screen appears. Note: On a T248X loaded with terminal emulation, you may need to press create the TE configuration file.

to

10. Use the TRAKKER Antares 2400 Menu System to set these network parameters: •

Time and date

•

Network activate (Ethernet)

•

Controller IP address (UDP Plus) or Host IP address (TCP/IP)

•

Terminal IP address

•

Network port

For help, see “Using the Menu System to Configure the Terminal” later in this guide.

Connecting to an RF Network The TRAKKER Antares 2485 or 2486 terminal can communicate with a host computer in Intermec’s 2.4 GHz RF network either through the DCS 300 or directly through the access points. The terminal uses one of these RF network protocol options to communicate with other devices: •

UDP Plus

•

TCP/IP

Each T2485 or T2486 ships with only one of these RF network protocols. To configure the T2485 or T2486 to use RF communications 1. Configure the DCS 300 (UDP Plus) or host (TCP/IP). For help with the DCS 300, see the DCS 300 System Manual (Part No. 067296). Note: You can use the DCS 300 or Model 200 Controller. For help with the controller, see the Model 200 Controller System Manual (Part No. 063439). 2. Configure the access point. For help, see your access point user’s manual.

19

Page 20

TRAKKER Antares 248X Getting Started Guide nugget c o d e 39

Connecting to an RF Network Host TCP/IP Direct Connect

UDP Plus

Ethernet

Access point

T2485/6

DCS 300

T2485/6

T2485/6

Access point

T2485/6

248XG.032

3. Press the f key on the keypad. The Boot Menu appears.

Note: If the backup battery charge is low, you may need to press information screen.

] to exit a battery to boot the terminal and initialize the firmware. The TRAKKER 4. Press Antares screen appears. Next, either a sample application screen or a terminal emulation (TE) application welcome screen appears. Note: On a T2485 or T2486 loaded with terminal emulation, you may need to to create the TE configuration file. press

5. Use the TRAKKER Antares 2400 Menu System to set these network parameters: •

Time and date

•

Network activate (2.4 GHz)

•

Controller IP address (UDP Plus) or Host IP address (TCP/IP)

•

Terminal IP address

•

RF domain

•

RF security identification (ID)

•

Network port (TCP/IP)

Note: If the T2485 or T2486 is on a different IP subnetwork from the DCS 300 or host, you must also configure the default router and subnet mask.

20

Page 21

nugget c o d e Installing 39 and Configuring the Terminal

For help, see the next section, “Using the Menu System to Configure the Terminal.”

Using the Menu System to Configure the Terminal You use the TRAKKER Antares 2400 Menu System to set serial port or network parameters on the T2480, T2481, T2485, or T2486. To configure the terminal

1. Press or scan this bar code to access the TRAKKER Antares 2400 Menu System: Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears. 2. Choose the System Menu and then press . Use the Set Time and Date option to set the current time and date. For help in the menu system, press .

248XG.014 b

] to exit the System Menu. The Main Menu appears. 4. Choose the Configuration Menu and then press The Configuration 3. Press

Menu appears. Use the Communications Menu to configure the network parameters and the serial port parameters. CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu

⁄ _` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XG.015

]

5. Press to exit the Configuration Menu. When prompted, save your changes to RAM. Press to exit the Main Menu and save your changes in flash memory.

]

21

Page 22

TRAKKER Antares 248X Getting Started Guide nugget c o d e 39

Using the Keypad The terminals come with a color-coded keypad to make it easier to remember key combinations. Position on the Keypad

Color

To Type the Character

Middle of the key or centered above the key

Grey

Press the key.

Left side above the key

Orange

Press the orange

Centered above a numeric key

Green

Press the green key, then the key.

Right side above the key

Blue

Press the blue key, then the key.

key, then the key.

Your terminal ships with function key labels. You can use the labels to identify custom function keys. Write the name for each function key on a strip of five labels. Insert the strip into the slot above the function keys. Note: There are two sizes of function key labels. Use the labels that are slightly larger if you have a T248X with an oversized function numeric keypad. Use the smaller labels for an alphanumeric keypad.

\

?

esc

Q tab

E

W

S

A

R

F

D

.

,

/

T

U

Y

G

H

J

F6

P

L bksp

: Ctrl

Z

"

F7

F1

O

K

Caps

I/O

-

+ I

X

F8

F2

C

V

F4

N

M Fn L

Fn R

_f

_f _ Enter

F10

F9

F3

B

F5

&

*

7

8

$

%

4

5

6

!

@

#

1

2

3

<

Ins

9

Del

0

>

.

248XG.040

22

Page 23

nugget c o d e Using 39the Status Lights

Using the Status Lights You can use the terminal’s status lights to monitor the status of backup battery power, RF and network communications, special keys, and bar code scanning. The status lights only flash or turn on to indicate the current status.

Power Network Connect Network Transmit Modifier Key Caps Lock Good Read User Defined 248XG.016

Developing Applications for the Terminal The TRAKKER Antares terminals ship loaded with a terminal emulation application, a screen mapping application, or a sample application. You can develop your own client/server application for the T248X and then download the application to the terminal. Intermec has two development tools that you can use to create applications: •

TRAKKER Antares Programmer’s Software Kit (Part No. 065332) has a full set of programming tools to help you create applications for the terminal.

•

EZBuilder™ (Part No. 066381) is a rapid application development tool that provides programmers and technically-oriented non-programmers with a quick and easy way to create applications for the terminal.

23

Page 24

TRAKKER Antares 248X Getting Started Guide nugget c o d e 39

Specifications Terminal Dimensions Length:

10.7 in (27.2 cm) 11.3 in (28.7 cm) with a badge scanner installed

Height:

9.6 in (24.4 cm)

Depth:

3.9 in (9.9 cm)

Weight:

9.5 lbs (4.3 kg)

Power Specifications Operating (with power supply):

95 to 250 VAC, 50 to 60 Hz, 125 mA

Memory Backup:

Rechargeable NiCad 700 mA battery pack

Electrical Specifications Models: Electrical rating:

T2480, T2481, T2485, and T2486

S 12V, 750 mA

Temperature and Environmental Specifications Operating the terminal:

-4°F to +122°F

-20°C to +50°C

Storing the terminal:

-4°F to +140°F

-20°C to +60°C

Charging the backup battery:

+32°F to +104°F

0°C to +40°C

Relative humidity:

0 to 95% non-condensing

Memory •

2MB programmable flash memory, 750K available for use

•

1MB battery-backed RAM, 512K available for use

•

Extended memory option for an additional 2MB flash

•

Extended memory option for an additional 2MB or 4MB SRAM storage drive (option for the T2480 or T2481 with Ethernet and the T2485 or T2486)

Where to Find More Information The TRAKKER Antares 248X Stationary Terminal User’s Manual (Part No. 066960) contains all the information necessary to install, configure, operate, and troubleshoot the T248X. For information on ordering a manual, contact your local Intermec sales representative.

24