Manual · Intermec
Intermec 2480, 2481, 2485 and 2486 Wall-Mount Bracket
Manual4 pagesPDF 248 KB
All 4 pages are below, each with its text.
Covers · 4 models
The models it covers
Intermec 2480Stationary data collection terminal for data entry from$1,275.003 in stock
Intermec 2481Stationary data collection terminal for data entry Call for availability
Intermec 2485Stationary data collection terminal for data entry Call for availability From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Intermec's instruction sheet (1998) for the wall-mount bracket kit for the TRAKKER Antares 2480, 2481, 2485 and 2486 terminals. It lists the kit's parts and shows how to fix the bracket to a wall, mount the terminal and power supply, route the cables and lock the bracket.
- Accessory
- Wall-mount bracket kit, Part No. 066708; opens so the back of the terminal can be worked on in place p. 1
- Fits
- TRAKKER Antares 2480, 2481, 2485 and 2486 terminals p. 1
- Kit contents
- Front and back panels, six nuts, two cable organizers, power supply holder, five mounting screws, cable tie wraps p. 1
- Screws to supply
- Four screws up to 5/16 inch (8 mm) in diameter p. 1
- Wall surface
- 1/2-inch thick wood or 14-gage steel p. 1
- Security
- Padlock tabs on the front and back panels p. 3
- Related manual
- TRAKKER Antares 248X Stationary Terminal User's Manual, Part No. 066960 p. 1
- Sheet number
- P/N 066994-001 p. 4
What this manual walks you through
- Fixing the bracket back panel to the wall p. 1
- Fastening the terminal to the front panel and hanging it p. 2
- Mounting the power supply and routing the cables p. 2, 3
- Closing and padlocking the bracket p. 3
Good to know
- Mount the bracket and terminal according to local building codes. p. 1
- Leave room under the screw heads so cables fit through the exit ports and behind the bracket. p. 1
- Fit the power supply in its holder with the AC cable toward the bottom, to keep out dust and moisture. p. 2
Questions this manual answers
What is the part number of the Intermec 2480 wall-mount bracket kit?
Part No. 066708. p. 1
What screws do I need to hang the 248X wall-mount bracket?
Four screws up to 5/16 inch (8 mm) in diameter, into 1/2-inch thick wood or 14-gage steel; they are not in the kit. p. 1
Can the 2480 wall-mount bracket be locked?
Yes. A padlock can go through the padlock tabs on the front and back panels. p. 3
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
TRAKKER Antares 248X Wall-Mount Bracket Instruction Sheet The wall-mount bracket easily attaches to your TRAKKER Antares 2480, 2481, 2485, or 2486 terminal, enabling you to secure your terminal to a wall. The bracket opens so you can work on the back of the terminal without taking it out of the bracket. Your wall-mount bracket kit (Part No. 066708) contains these parts:
Wall-mount bracket front and back panels
Six nuts•Two cable organizers•Power supply holder•Five mounting screws•Cable tie wraps
To mount the bracket, you need to provide four screws up to 5/16 inch (8 mm) in diameter. Mount the bracket to either a 1/2-inch thick wood surface or a 14-gage steel surface. Mount the bracket and terminal in accordance with local building codes. To secure the bracket to the wall 1. Swing open the front panel and lift up to remove. 2. Using the back panel as a template, mark and drill four holes in the wood or steel surface. 3. Attach the back panel using four screws. Leave enough room between the head of the screw and the back panel so that the cables will fit through the exit ports and between the bracket and the wall. To attach a terminal to the wall-mount bracket 1. If you received your wall-mount bracket with your terminal, do not connect the power supply, serial port cables, input device, Ethernet cable, or any relay wires until you have mounted the terminal to the wall. If you received your wall-mount bracket after your terminal, disconnect the power supply, serial port cables, input device, Ethernet cable, and any relay wires. The badge scanner cable can remain connected if the cable fits snugly against the bottom edge of the rear enclosure. For help disconnecting the cables and wires, see your TRAKKER Antares 248X Stationary Terminal User’s Manual (Part No. 066960).
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
Attaching a Terminal to the Wall-Mount Bracket
Front panel Hinge peg (2 places) Nut (2 places) Exit port (3 places) Badge scanner cable notch
LatchBack panel5/16"screw (4 places)
Mounting screw (5 places) Nut (2 places)
Vertical lock Nut (2 places) Cable organizer Power supply holder
Padlock tab (2 places) 248XI.002
2. Align the five mounting holes on the terminal with the holes on the front panel and make sure that the badge scanner cable notch goes over the badge scanner cable. 3. Using the five mounting screws in the kit, fasten the terminal to the front panel. 4. Align the hinge pegs with the holes on the front and back panels, slide the front panel past the vertical lock, and attach the front panel to the back panel. 5. Secure the power supply to the base using the power supply holder. The AC power supply cable that connects to a powered outlet must be oriented toward the bottom of the back panel. Note: Make sure the power supply is properly installed to prevent damage from dust and moisture.
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
6. Route the power supply cable (DC in), serial port cables, Ethernet cable, input device, and relay wires through the exit port and along the cable routing channel as shown in the illustration. Wall-mount bracket back panel Wall-mount bracket front panel
Back of terminalCable routing channelAC power to outletPower supply holder248XI.004
7. Use the cable tie wraps to organize the cables. 8. Connect the power supply, serial port cables, input device, Ethernet cable, and any relay wires to the terminal. For help, see your TRAKKER Antares 248X Stationary Terminal User’s Manual. 9. Fasten one or both cable organizers over the cables and wires. 10. Close the front panel and secure with the latch. To prevent someone from removing or tampering with the terminal, you can put a padlock through the padlock tabs on the front and back panels.
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 © 1998 Intermec All Rights Reserved
P/N 066994-001