Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Allen-Bradley High Performance Visible Laser Diode Scanner Document Update

Manual · Allen-Bradley

Allen-Bradley High Performance Visible Laser Diode Scanner Document Update

Manual2 pagesPDF 31 KB

Both pages are below, each with its text.

What this file really is

The old site listed this file as “34” for the Allen-Bradley 2755-DS. The update is for the 2755-LD4 and -LD8 scanners; 2755-DS is not named.

Download the PDF31 KB

Filed with · 1 model

Also filed with these models on the old site

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

A two-page document update to the user manual for the Allen-Bradley High Performance Visible Laser Diode Scanner, 2755-LD4z1, -LD4z4, LD8z1 and -LD8z4. It corrects the 2755-LD4 scan rate from 200 to 186 scans per second in the overview table, the worked scans-per-symbol examples and the specifications, and gives the factory scan angle setting. The site files it under the 2755-DS, which the update does not mention.

Document
Update to the High Performance Visible Laser Diode Scanner User Manual (2755-LD4z1, -LD4z4, LD8z1, -LD8z4) p. 1
2755-LD4 scan rate
186 scans per second, corrected from 200 p. 1, 2
Minimum scan rate
176 scans per second (186 less 5.4%) in the LD4 calculation examples p. 1
Factory scan angle
3/4 scan angle p. 2
Corrected examples
Scans per symbol: 5.46 (page 3-11, Example 1), 9.83 (page 3-12, Example 2), 7.04 (page 3-13, Example 1) p. 1, 2

What this manual walks you through

  • Correcting the 2755-LD4 scan rate in the user manual p. 1, 2
  • Recalculating the scans-per-symbol examples p. 1, 2
  • Reading the scan angle adjustment switch positions p. 2

Good to know

  • The update is meant to be kept with the scanner user manual. p. 1

Questions this manual answers

What is the scan rate of the 2755-LD4 scanner?

186 scans per second; this update corrects the 200 scans per second printed in the user manual. p. 1

What is the factory scan angle setting of the high performance laser diode scanner?

The 3/4 scan angle. p. 2

What minimum scan rate should be used in 2755-LD4 scans-per-symbol calculations?

176 scans per second, which is 186 scans per second less 5.4%. p. 1

The file

Size and text

Pages2
PDF31 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Allen-Bradley High Performance Visible Laser Diode Scanner Document Update

The text of page 1, from the PDF itself

Document Update

High Performance Visible Laser Diode Scanner (Catalog Numbers 2755-LD4z1, -LD4z4, LD8z1, -LD8z4)

Overview

This document describes an update to the High Performance Visible Laser Diode Scanner User Manual. Keep this Document Update with the manual.

Description of Change

The “LD4” family of scanners are listed in this publication as having 200 scans per second. This has been changed to 186 scans per seconds. Please make the following changes: D Page 2-2, in the “Overview of Scanner” table, change the

description for Catalog Numbers 2755-LD4z1 and 2755-LD4z4 from 200 scans per second to 186 scans per second. D Page 3-11, under “Example 1:”, change:

A = 200 scans/second–5% = 190 scans/second (minimum scan rate), to: A = 186 scans/second–5.4% = 176 scans/second (minimum scan rate) D Page 3-11, under “Example 1:”, change:

S = 190 scans/second x (5.525 inches – 4.75 inches) / (25 inches/second) S = 5.89 scans, to: S = 176 scans/second x (5.525 inches – 4.75 inches) / (25 inches/second) S = 5.46 scans D Page 3-12, under “Example 2:”, change:

A = 200 scans/second–5% = 190 scans/second (minimum scan rate), to: A = 186 scans/second–5.4% = 176 scans/second (minimum scan rate) D Page 3-12, under “Example 2:”, change:

S = 190 scans/second x (8.1 inches – 4.75 inches) / (60 inches/second) S = 10.6 scans, to: S = 176 scans/second x (8.1 inches – 4.75 inches) / (60 inches/second) S = 9.83 scans

Page 2 of Allen-Bradley High Performance Visible Laser Diode Scanner Document Update

The text of page 2, from the PDF itself

2

Variable Content TTL:Chap Is Linked To HD:Running

D Page 3-13, under “Example 1:”, change:

A = 200 scans/second–5% = 190 scans/second (minimum scan rate), to: A = 186 scans/second–5.4% = 176 scans/second (minimum scan rate) D Page 3-13, under “Example 1:”, change:

S = 190 scans/second x 1 inch/(25 inches/second) S = 7.6 scans, to: S = 176 scans/second x 1 inch / (25 inches/second) S = 7.04 scans D Chapter 7 Specifications under Optical “Scan Rate (Nominal)”,

change: Catalog No. 2755-LD4 Catalog No. 2755-LD4

200 Scans/Second, to: 186 Scans/Second

D Page 5-3, factory default setting for the scan angle is 3/4.

Figure 5.2 Scan Angle Adjustment Switch Positions Position #1 Full Counterclockwise

Position #2 1 Position Clockwise From Fully Counterclockwise

Position #3 1 Position Counterclockwise From Fully Clockwise

Position #4 Full Clockwise

Full Scan Angle

3/4 Scan Angle (Factory Setting)

1/2 Scan Angle

1/2 Scan Angle (same as position #3)

Rockwell Automation helps its customers receive a superior return on their investment by bringing together leading brands in industrial automation, creating a broad spectrum of easy-to-integrate products. These are supported by local technical resources available worldwide, a global network of system solutions providers, and the advanced technology resources of Rockwell.

Worldwide representation. Argentina • Australia • Austria • Bahrain • Belgium • Bolivia • Brazil • Bulgaria • Canada • Chile • China, People’s Republic of • Colombia • Costa Rica • Croatia • Cyprus Czech Republic • Denmark • Dominican Republic • Ecuador • Egypt • El Salvador • Finland • France • Germany • Ghana • Greece • Guatemala • Honduras • Hong Kong Hungary • Iceland • India • Indonesia • Iran • Ireland • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Macau • Malaysia • Malta • Mexico • Morocco The Netherlands • New Zealand • Nigeria • Norway • Oman • Pakistan • Panama • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic of • Spain • Sweden • Switzerland • Taiwan • Thailand • Trinidad • Tunisia • Turkey • United Arab Emirates United Kingdom • United States • Uruguay • Venezuela Rockwell Automation Headquarters, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 Rockwell Automation European Headquarters, Avenue Hermann Debroux, 46, 1160 Brussels, Belgium, Tel: (32) 2 663 06 00, Fax: (32) 2 663 06 40 Rockwell Automation Asia Pacific Headquarters, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 World Wide Web: http://www.ab.com Publication 2755-832.2 October 1998

41062-042-01(B)

Supersedes Publication 2755-832.2 November 1997 Copyright 1998 Allen-Bradley Company, Inc. Printed in USA

Publication XXXX-XX.X – April 1996