A bar code programming guide for the Allen-Bradley 2-D hand-held bar code scanner, catalog number 2755-HTG-4. Readers configure the scanner by scanning the printed Code 128 setup symbols. It covers symbology and data format options, communication setup for the RS-232, IBM and DEC keyboard wedge and scanner emulation Synapse cables, ADF rule bar codes, and application setups for the Enhanced Decoder (2755-DD/DS), the Flexible Interface Module, SLC 5/03 and 5/04 and PLC-5 controllers, and DTAM Plus DeviceNet.
Its parts
- Preface
- Scanner Configuration
- RS-232 Synapse Cable (Communication Setup)
- IBM Keyboard Wedge (Communication Setup)
- DEC VT520 Keyboard Wedge (Communication Setup)
- DEC VT220/320/420 Keyboard Wedge Cable (Communication Setup)
- Scanner Emulation Cable (Communication Setup)
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
A bar code programming guide (Publication 2755-6.7, September 1996) for the Allen-Bradley 2755-HTG-4 2-D hand-held bar code scanner and its RS-232, keyboard wedge and scanner emulation Synapse cables. It prints the configuration bar codes for scanner options, cable communications, Advanced Data Formatting rules, and setups with the 2755-DD/DS Enhanced Decoder, flexible interface module, SLC 5/03 and 5/04, PLC-5 and DTAM Plus DeviceNet. The site files it under the 2755-DS, which the guide covers only as a host device.
- Device
- 2-D hand-held bar code scanner, 2755-HTG-4 p. 1
- Configuration symbols
- All Code 128, which the scanner always reads; defaults are marked with an asterisk p. 8
- RS-232 cables
- 2755-HFC-SR2-01 (25-pin) and 2755-HFC-SR3-01 (9-pin) Synapse cables p. 8, 130, 154
- Keyboard wedge cables
- IBM or compatible: 2755-HFC-SP1-01 and 2755-HFC-SP2-01 p. 8, 44
- Scanner emulation cable
- 2755-HFC-SA1-01 p. 8, 59
- Scanner defaults
- All symbologies on, Code 39 Full ASCII on, Enter suffix, high beeper tone, smart raster on, slab raster, 30-second time delay to low power mode p. 3, 11
- Scan pattern options
- Slab raster (default), aiming dot with normal or extended timeout, always raster on or off, smart raster on or off p. 31
- RS-232 cable defaults
- No parity, 1 stop bit, 8 data bits, no hardware or software handshaking, 2-second response timeout p. 33
- Keyboard wedge defaults
- IBM PC/AT host, North American country setting, 5 millisecond intercharacter delay p. 44
- Scanner emulation defaults
- Standard emulation, 80 millisecond leading margin, 3-second emulation timeout, margin low / bar high polarity p. 59
- Allen-Bradley hosts
- Enhanced Decoder (2755-DD/DS), Flexible Interface Module (2760-RB), SLC 5/03 and 5/04, PLC-5, DTAM Plus DeviceNet p. 9, 126, 133
- Enhanced Decoder hookup
- Scanner emulation cable 2755-HFC-SA1-01 plus gun adapter 2755-NC16; AUX port pass-through uses 2755-HFC-SR2-01 and a null modem adapter p. 127, 130
- Other host hookups
- Flexible Interface Module (2760-RB): 2755-HFC-SR2-01 and an SFC2 Protocol Cartridge; PLC-5 Channel 0: 2755-HFC-SR2-01; DTAM Plus: 2755-HFC-SR3-01 p. 133, 134, 147, 154
- Advanced Data Format
- Bar code rules that modify decoded data before it is sent to the host p. 9, 66
What this manual walks you through
- Following the configuration sequence for cable and host p. 9
- Restoring the scanner's default settings p. 10, 11
- Setting pause and decode attempt durations p. 29
- Choosing raster and aiming dot options p. 31
- Setting up the RS-232 Synapse cable p. 33
- Setting up the IBM keyboard wedge cables p. 44
- Setting up the scanner emulation cable p. 59
- Building Advanced Data Formatting rules p. 66
- Connecting the scanner to an Enhanced Decoder, including AUX port pass-through p. 126, 127, 128, 130
- Connecting the scanner to SLC 5/03, 5/04 and PLC-5 controllers p. 139, 140, 146, 147
Good to know
- Do not install a Synapse cable while power is applied to the cable or the host (decoder, interface module, SLC or PLC); it may damage the equipment. p. 126, 133, 139, 146
- In the host hookups the power supply is connected last. p. 127
- The flexible interface module needs no special scanner configuration, but the cable communication settings must be set. p. 134
Questions this manual answers
How do I reset the 2755-HTG-4 scanner to its default settings?
Scan the Set Defaults label at the start of Chapter 1. p. 10
Which cables does the 2755-HTG-4 2-D scanner use?
RS-232 Synapse cables 2755-HFC-SR2-01 and 2755-HFC-SR3-01, IBM keyboard wedge cables 2755-HFC-SP1-01 and 2755-HFC-SP2-01, scanner emulation cable 2755-HFC-SA1-01, and DEC keyboard wedge cables. p. 8
How does the 2755-HTG-4 scanner connect to a DTAM Plus operator interface?
With the 9-pin RS-232 Synapse cable 2755-HFC-SR3-01. p. 154
Where are the 2755-HTG-4 configuration settings explained?
In the user manual for the 2-D hand-held bar code scanners, Publication 2755-6.4. p. 8
Can the 2755-HTG-4 change scanned data before sending it to the host?
Yes, the Advanced Data Format codes in Appendix A modify decoded data before it is transmitted. p. 9
Contents
Chapters and sections
Each line opens the PDF at its page.
- Front Cover1
- Important User Information2
- Preface - Read this First8
- 1 - Scanner Configuration10
- Set Default Parameters10
- Select The Symbologies You Want to Enable or Disable12
- Transmit UPC-A / UPC-E Check Digit16
- Convert UPC-E to UPC-A16
- Decode UPC / EAN Supplements17
- Convert EAN-8 to EAN-1317
- Select UPC-A Preamble18
- Select UPC-E Preamble18
- Select Code 39 - Code Lengths19
- Select Codabar Code Lengths20
- Select Interleaved 2 of 5 Code Lengths21
- Scan 2 Digit Code Length22
- Select Prefix/Suffix Options23
- Prefix/Suffix - 4 Digit ASCII Equivalent Value24
- Data Transmission Format25
- Transmit No-Read Message26
- Transmit LRC Checksum26
- Transmit Code ID Character27
- Beeper After Good Decode / Beeper Tone28
- Decode Buffering28
- Pause Duration29
- Decode Attempt Duration29
- Pause/Decode Attempt Duration Values30
- Smart Raster31
- Hand-Held Options31
- 2 - RS-232 Synapse Cable (Communication Setup)32
89 more lines, from page 40 on
- RS-232 Synapse Cable Beep On <BEL>40
- 3 - IBM Keyboard Wedge (Communication Setup)44
- 4 - DEC VT520 Keyboard Wedge (Communication Setup)49
- 5 - DEC VT220/320/420 Keyboard Wedge Cable (Communication Setup)54
- DEC VT220/320/420 Keyboard Wedge Interface Cable Defaults54
- DEC VT220/320/420 Keyboard Wedge Synapse Cable Host55
- DEC VT220/320/420 Keyboard Wedge Country Selection55
- DEC VT220/320/420 Keyboard Wedge Unknown Characters57
- DEC VT220/320/420 Keyboard Wedge Intercharacter Delay57
- DEC VT220/320/420 Keyboard Wedge Advanced Features58
- 6 - Scanner Emulation Cable (Communication Setup)59
- Scanner Emulation Synapse Cable Defaults59
- Scanner Emulation Host60
- Scanner Emulation Variable Leading Margin61
- Scanner Emulation Check for Decode LED61
- Scanner Emulation Timeout62
- Scanner Emulation Polarity63
- Send Bar Codes with Unknown Characters63
- Scanner Emulation Convert All to Code 3964
- Scanner Emulation Code 39 to Code 39 Full ASCII64
- Scanner Emulation Cable Advanced Features65
- A - ADF Bar Codes66
- Special Commands - Start/Save Rules67
- Special Commands - Erase/Quit Rules68
- Special Commands - Disable Rule Sets69
- Criteria - Code Types70
- Criteria - Code Lengths72
- Criteria - Specific Data String75
- Criteria - Numeric Keypad76
- Criteria - Specific Data String77
- Criteria - Rules Belongs to Sets78
- Actions - Send Characters / Data79
- Actions - Skip Ahead / Back83
- Actions - Spaces and Zeroes87
- Actions - Send Value88
- Actions - Beeps89
- Actions - Pad Spaces90
- Actions - Pad Zeros94
- Actions - Send Control Characters98
- Actions - Send Keyboard Characters102
- Actions - AlphaNumeric Keyboard114
- Actions - Turn of Rule Set125
- B - Enhanced Decoder Application126
- C - Flexible Interface Module Application133
- D - SLC 5/03, 5/04 Controller Application139
- E - PLC-5 Controller Application146
- F - DTAM Plus DeviceNet Application153
- G - ASCII Chart159
- Test Symbols164
- Back Cover165
The whole text · 21 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 71-7
- Pages 8 to 158-15
- Pages 16 to 2316-23
- Pages 24 to 3124-31
- 2 - RS-232 Synapse Cable (Communication Setup)32-43
- 3 - IBM Keyboard Wedge (Communication Setup)44-48
- 4 - DEC VT520 Keyboard Wedge (Communication Setup)49-53
- 5 - DEC VT220/320/420 Keyboard Wedge Cable (Communication Setup)54-58
- 6 - Scanner Emulation Cable (Communication Setup)59-65
- A - ADF Bar Codes, pages 66 to 7566-75
- A - ADF Bar Codes, pages 76 to 8576-85
- A - ADF Bar Codes, pages 86 to 9586-95
- A - ADF Bar Codes, pages 96 to 10596-105
- A - ADF Bar Codes, pages 106 to 115106-115
- A - ADF Bar Codes, pages 116 to 125116-125
- B - Enhanced Decoder Application126-132
- C - Flexible Interface Module Application133-138
- D - SLC 5/03, 5/04 Controller Application139-145
- E - PLC-5 Controller Application146-152
- F - DTAM Plus DeviceNet Application153-158
- Pages 159 to 165159-165
The file