Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Laser Programming Guide

Manual · Wasp

Laser Programming Guide

Manual100 pagesPDF 674 KB

Programming guide for the Wasp Laser scanner: bar code labels to select the host interface, symbologies and general scanner features.

Download the PDF674 KB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The bar code programming guide for the Wasp Laser scanner, published by Informatics, Inc. It explains Programming Mode and the SET and END labels, how to change interfaces, then gives programming labels for IBM, OCIA, wand emulation, RS-232 and PC keyboard wedge interfaces, prefix and suffix settings, symbology options (UPC/EAN, Code 39, Code 128, Interleaved and Standard 2 of 5, Codabar, MSI/Plessey) and general features such as beeper, read verification and low power mode. A factory defaults table closes the guide.

Its parts

  1. Introduction
  2. Programming Overview
  3. Interface Selection
  4. Label Transmit Format Configuration Items
  5. Symbologies
  6. General Features
  7. Appendix A
  8. Appendix B
  9. Factory Defaults

From the manual

Key facts from this manual

Each line names its page in the PDF.

The Laser Programming Guide published by Informatics for Wasp Laser bar code scanners (part number R44-1568, revision B). It is filed under the Wasp WLS-9000 but never names that model, and a few options are marked for the QuickScan 6000 Plus only. It shows how to change the scanner's interface and set communication, symbology, beeper, read verification and power options by scanning programming bar codes.

Read for this summary: pages 1 to 14, 22 to 27, 30 to 32, 52 to 54 and 86 to 93 of 100.

Programming
Scan programming bar codes between a SET label and an END label, or send commands from the host p. 11
Interfaces
OCIA (PSC, NCR 8-Bit, SNI, NCR 9-Bit), RS-232 (PSC, SNI), IBM ports, Wand Emulation, Keyboard Wedge p. 9
IBM ports
IBM 4683/84, 4693/94 Port 5B and Port 9A, 9B, 9C, 9E; 4682/92 Port E p. 9
Interface groups
Each scanner ships with at least two interface types, such as Keyboard Wedge/Wand Emulation or OCIA/RS-232 p. 8
RS-232 baud rates
1200, 2400, 4800, 9600, 19200, 38400 p. 23
RS-232 data format
Seven or eight data bits; parity none, even, odd, mark or space; one or two stop bits p. 24
Handshaking
CTS/RTS flow control, CTS scan control, or XON/XOFF software control (one at a time) p. 25, 26
Keyboard wedge types
Ten types, A to J: PC/XT, AT and PS/2 with US or foreign keyboard, IBM 3xxx, PS/55 5530T, NEC 9801 p. 30
Symbologies
UPC-A and E, EAN-8 and 13, Code 39/Pharmacode, Interleaved 2 of 5, IATA, Standard 2 of 5, Codabar, Code 93, Code 128, MSI/Plessey p. 52, 54
UPC/EAN add-ons
P2, P5 and C128 add-ons p. 52
Read verification
One to four matching reads before transmit, for all symbologies or by symbology p. 88, 89
Beep duration
Short (100msec), medium (250msec) or long (500msec) p. 86
Low power modes
Low Power Idle; Very Low Power Mode on RS-232 and Wand Emulation only p. 91
Stand mode
AutoSense Stand Mode for hands-free use in the Wasp Laser stand accessory p. 92

What this manual walks you through

  • Changing the scanner's interface cable and interface software p. 8, 9
  • Running a programming session with the SET and END labels p. 11, 12
  • Returning the scanner to its factory settings p. 13
  • Setting RS-232 baud rate, data bits, parity and stop bits p. 22, 23, 24
  • Choosing hardware or software handshaking p. 25, 26
  • Selecting a keyboard wedge type and laptop or no-keyboard mode p. 30, 31, 32
  • Enabling or disabling bar code symbologies p. 52, 53, 54
  • Setting read verification for all or individual symbologies p. 88, 89, 90
  • Adjusting the good read beep, low power, debug and stand modes p. 86, 87, 91, 92

Good to know

  • Do not use Very Low Power Mode together with AutoSense Stand Mode. p. 91
  • Removing power before the END label is scanned discards that session's programming. p. 12
  • The Return to Factory Settings label disables every feature programmed since installation. p. 13
  • The RS-232 ACK/NAK options apply to the QuickScan 6000 Plus only. p. 27
  • The guide recommends disconnecting power before plugging or unplugging cables. p. 8

Questions this manual answers

How do I reset a Wasp laser scanner to factory settings?

Scan the Return to Factory Settings label, which restores the settings configured at the factory for the scanner's original interface. p. 13

What do six rapid beeps mean on a Wasp laser scanner?

It is the error tone, sounded for a non-programming label in Programming Mode, or for a label invalid to the current interface. p. 10, 12

What baud rates can the Wasp laser scanner use over RS-232?

1200, 2400, 4800, 9600, 19200 or 38400. p. 23

How do I use the Wasp laser scanner keyboard wedge with a laptop?

Scan the Laptop/No External Keyboard label so the scanner supplies the acknowledge signal itself; switch back to Keyboard Attached on a PC with a keyboard. p. 32

How do I know the scanner is in programming mode?

The green LED flashes continuously at 1Hz, and regular bar codes are rejected until the END label is scanned. p. 12

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Introduction7
    1. Understanding the Basics7
    2. Integrating Peripherals With Host Systems7
    3. Changing Interfaces8
    4. Customizing Your Scanner Operation10
    5. Programming Overview11
    6. What Is Programming Mode?11
    7. How To Program Using Bar Codes11
    8. The Programming Session12
    9. Scanner Response When In Programming Mode12
    10. If You Make a Mistake...13
    11. Return to Factory Settings13
    12. Where To Go From Here14
    13. IBM 4683/84 • 4693/94 Port 5B I/F Selection15
    14. IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E I/F Selection16
    15. IBM 4682/92 Port E Interface Selection17
    16. NCR OCIA Eight Bit (short format) I/F Selection18
    17. NCR OCIA Nine Bit (long format) I/F Selection18
    18. SNI OCIA Interface Selection18
    19. OCIA Options19
    20. Wand Emulation Interface Selection20
    21. RS-232 Interface Selection22
    22. SNI RS-232 Interface Selection22
    23. Hardware Control25
    24. Software Control26
    25. RS-232 ACK/NAK Options (QS 6000 Plus ONLY)27
    26. PC Keyboard Wedge Interface Selection30
    27. PC Keyboard Wedge – Connect to a Laptop/No Keyboard Attached32
    28. Label Transmit Format Configuration Items38
    29. Prefix & Suffix38
    30. ASCII Character Set44
    31. Symbologies52
    32. Symbology Options Overview53
    33. Symbology Selection55
    34. UPC/EAN Options58
    35. UPC/EAN Expansion59
    36. UPC/EAN Add-Ons60
    37. C128 and Custom Add-Ons60
    38. Price/Weight Check Digit61
22 more lines, from page 64 on
  1. Code 39 Options64
    1. Code 128 Options68
    2. Interleaved 2 of 569
    3. Check Digit and Variable Length Label Selections70
    4. Standard 2 of 573
    5. Check Digit and Variable Length Label Selections74
    6. Codabar Options78
    7. Codabar Check Digit & Variable Length79
    8. Codabar Start/Stop Character80
    9. Codabar Fixed Length81
    10. MSI/Plessey Check Digit83
    11. MSI/Plessey Fixed Length84
    12. Good Read Beeper Settings86
    13. Read Verification88
    14. Low Power Mode91
    15. Debug Mode92
    16. AutoSense® Stand Mode92
    17. Appendix A93
    18. Host Programming93
    19. Creating MultiFunction Labels93
    20. Need More Information?93
    21. Appendix B94

From the PDF’s own bookmarks.

The whole text · 10 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100

The file

Revision and size

RevisionPart Number R44-1568, Rev. B
PublisherInformatics, Inc.
Pages100
PDF674 KB
TextText from the PDF itself; pages 29, 51, 67, 77 and 96 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 100

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 100
Page 2
Page 2of 100
Page 3
Page 3of 100