Page 11
This section describes how to set the scanner's programmable features. These features can be configured using the bar code labels contained in this manual or by using commands sent from the host. Refer to Appendix A, Additional Information, for host programming details. If you program the scanner using these bar codes, the scanner stores the changes until reprogrammed.
WHAT IS PROGRAMMING MODE? To change the scanner's programmed settings, it is necessary to place the scanner in Programming Mode using the special SET label. This ensures that the scanner only recognizes the special programming labels contained in this programming guide.
HOW TO PROGRAM USING BAR CODES The following pages contain special bar code labels that are used to change or enable the scanner's programmable options. All programming sessions follow this order, unless otherwise instructed: 1.
Scan the SET label at the top of the page. The scanner will emit a 'good read' beep, indicating it has read the label.
2.
Scan the feature label(s) for the programmable options you wish to enable. With few exceptions1, the scanner will emit a triple beep each time you scan a valid programming label. (Note that not all features are available for all interfaces and that the scanner will sound an error tone when scanning programming labels for features invalid to the current interface.)
3.
Scan the END label at the bottom of the page to complete the programming session and exit Programming Mode. The scanner will sound one 'good read' beep upon exiting Programming Mode.
4.
Maintain a good record of all changes made to ensure that you know if the original factory settings have been changed.
1
Some features, such as Minimum Label Length or Label ID, require you to select the length by scanning a series of single-digit bar codes. A single 'good read' beep is sounded when scanning these single digits in Programming Mode. Only the final required digit in the sequence will produce a triple beep when scanned, indicating a successfully programmed feature.
5
GENERAL INFORMATION
PROGRAMMING OVERVIEW
Page 12
GENERAL INFORMATION
THE PROGRAMMING SESSION It is possible to program multiple features during a single programming session (a programming session is defined as the period of time between scanning the “set” label and scanning the “end” label). However, it is recommended that sessions be limited to one feature, as it can be difficult to discover where an error has been made, should you make a mistake in the programming sequence. Additionally, it can be confusing to determine which features may or may not have been successfully set following such a session. The scanner will not exit Programming Mode unless the END label is scanned. Disconnecting power during Programming Mode, before scanning the END label, will cause the scanner to forget any programming labels scanned during the current programming session and will cause the scanner to return to its previous settings.
SCANNER RESPONSE WHEN IN PROGRAMMING MODE As discussed earlier, Programming Mode is entered by scanning a SET label. The green LED will flash continuously at 1Hz duty cycle while the scanner is in Programming Mode. As long as it is in Programming Mode, the scanner will not decode regular bar code labels and will only enable features supported by the currently active interface. Scanning regular (non-programming) bar code labels, the scanner will reject the label, sounding an error tone (six rapid beeps). Scanning a valid programming label, a.
If the feature is supported by the active interface, the scanner will sound three beeps.
b. If incorrect programming has been entered, the error tone will be sounded (six rapid beeps). Additionally, when programming a feature requiring you to scan single digits to set a multi-digit number, such as Minimum Label Length or Label ID, scanning the END label before completing all input will result in an error tone and cause the scanner to exit Programming Mode. Under these circumstances, the current feature you were trying to set is thrown out; any previous labels scanned during the session will take effect.
6
Wasp Laser Scanner Programming Guide
Page 13
If, during a programming session, you find that you are unsure of the scanner's settings or wish to re-set the scanner's configuration, use the Return to Factory Settings label on this page to return the scanner's configuration to the factory settings. Scanning this label will also reset any changes made during previous programming sessions.
RETURN TO FACTORY SETTINGS Scan this label to return the scanner to the default settings configured at the factory for your scanner’s original interface specifications. This label is typically used to return the scanner to a “known” operating state when the present programming status is not known, faulty, or suspect. NG NI R A W
Use this label with caution, since it will disable ALL features that may have been programmed since the scanner’s installation.
If you don't have a record of your site/system's original configuration, you may need to call Informatics for assistance to return the scanner to normal function. Please be prepared to provide information about the store/ chain, location, and other pertinent information about the scanner being repaired.
7
GENERAL INFORMATION
IF YOU MAKE A MISTAKE...
Page 14
GENERAL INFORMATION
WHERE TO GO FROM HERE Programming is easy and straightforward if you follow these steps: 1.
If you are changing interfaces, first connect the scanner to the new host using the new interface cable. Scan the interface enable bar code label1 .
2.
Scan any feature labels that are unique to the interface you are currently programming. These interface specific programming labels immediately follow each interface selection label.
3.
Turn to the Symbology section if you are going to change any bar code symbologies or modify any symbology related features.
4.
Turn to the General Features section of this guide if you wish to change or modify any of the scanner's other features.
Once the necessary changes have been made, and you have scanned the END label, you are ready to scan.
1
8
This step is not neccessary unless you require a specific interface sub-type such as SNI OCIA or IBM sub-type 4682/92 Port E. Interface software is automatically selected when the hardware connection (via a new interface cable) is made.
Wasp Laser Scanner Programming Guide
Page 15
IBM 4683/84 • 4693/94 PORT 5B INTERFACE SELECTION Scan this label to enable the IBM 468x Port 5B interface.
IBM INTERFACES
IBM 4683/84 • 4693/94 PORT 5B SETTINGS Data Format: Send As Code 39, converts bar codes data (UPC/EAN, add-ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host. These settings are for IBM 4683/84 • 4693/94 Port 5B interface ONLY. Limit Command Set, is an option that causes the scanner to ignore 'enable scanner' and 'disable scanner' commands sent from the host. Transmit Unsolicited Status1, when enabled, this option causes the scanner to transmit a status message to the host upon receipt of an "SNRM".
SET
------------------------------------SEND AS CODE 39 ------------
DATA FORMAT
DON' T SEND AS CODE 39 -----ENABLE LIMIT COMMAND SET --DISABLE LIMIT COMMAND SET -TRANSMIT UNSOLICITED STATUS DON' T TRANSMIT UNSOLICITED STATUS END 1
-------------------------------------
For this IBM interface, the setting for Unsolicited Status is normally Enabled.
9
Page 16
IBM 4683/84 • 4693/94 PORT 9A, 9B, 9C, 9E I/F SELECTION Scan this label to enable the IBM 468x/9x Port 9x interface.
Data Format: Send As Code 39, converts bar codes data (UPC/EAN, add-ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host. These settings are for IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E interface ONLY. Limit Command Set, is an option that causes the scanner to ignore 'enable scanner' and 'disable scanner' commands sent from the host. Transmit Unsolicited Status1, when enabled, this option causes the scanner to transmit a status message to the host upon receipt of an "SNRM".
SET
------------------------------------SEND AS CODE 39 -----------DON'T SEND AS CODE 39 ------
DATA FORMAT
IBM INTERFACES
IBM 4683/84 • 4693/94 PORT 9A, 9B, 9C, 9E SETTINGS
ENABLE LIMIT COMMAND SET --DISABLE LIMIT COMMAND SET -TRANSMIT UNSOLICITED STATUS DON'T TRANSMIT UNSOLICITED STATUS
END 1
10
-------------------------------------
For this IBM interface, the setting for Unsolicited Status is normally Disabled.
Wasp Laser Scanner Programming Guide
Page 17
IBM 4682/92 PORT E INTERFACE SELECTION
IBM 4682/92 PORT E SETTINGS Data Format: Send As Code 39, converts bar codes data (UPC/EAN, add-ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host. These settings are for IBM 4682/92 Port E interface ONLY. Limit Command Set, is an option that causes the scanner to ignore 'enable scanner' and 'disable scanner' commands sent from the host. Transmit Unsolicited Status1, when enabled, this option causes the scanner to transmit a status message to the host upon receipt of an "SNRM".
SET
------------------------------------SEND AS CODE 39 ------------
DATA FORMAT
DON'T SEND AS CODE 39 -----ENABLE LIMIT COMMAND SET --DISABLE LIMIT COMMAND SET -TRANSMIT UNSOLICITED STATUS DON'T TRANSMIT UNSOLICITED STATUS END 1
-------------------------------------
For this IBM interface, the setting for Unsolicited Status is normally Disabled.
11
IBM INTERFACES
Scan this label to enable the IBM 468x/9x Port E interface.
Page 18
OCIA INTERFACE SELECTION Scan this label to enable the OCIA interface.
NCR OCIA EIGHT BIT (SHORT FORMAT) INTERFACE SELECTION Scan this label to enable the NCR OCIA (short format) interface.
OCIA INTERFACES
NCR OCIA NINE BIT (LONG FORMAT) INTERFACE SELECTION Scan this label to enable the NCR OCIA Nine Bit (long format) interface.
SNI OCIA INTERFACE SELECTION Scan this label to enable the SNI OCIA interface.
12
Wasp Laser Scanner Programming Guide
Page 19
OCIA OPTIONS Use these labels to change the settings as desired. The following brief descriptions explain each selection. Beep if Not on File, when enabled requires the scanner to beep when a label is scanned that is not on file. Host Commands, when enabled allows the scanner to accept commands directly from the host.
BEEP IF NOT ON FILE
ENABLE ------------------------
HOST COMMANDS
-------------------------------------
ENABLE ------------------------
INTERCHARACTER DELAY
SET
ENABLE ------------------------
END
OCIA INTERFACES
Intercharacter Delay, refers to a pause, if any, between each character before being sent to the host. This time delay is used to control the flow of data from the scanner, but it should not be required for most applications. When enabled, OCIA intercharacter delay is set at 70µs.
DISABLE -----------------------
DISABLE -----------------------
DISABLE -----------------------------------------------------------
13
Page 20
WAND EMULATION INTERFACE SELECTION Scan this label to enable the Wand Emulation interface.
SET
-------------------------------------
POLARITY
WAND EMULATION SETTINGS
SPACE LOW, B AR HIGH --------
LOW (660 µS) --------------HIGH (330 µS) -------------TRANSMIT IN N ORMAL FORMAT --
DATA FORMAT
WAND EMULATION INTERFACE
SIGNAL SPEED
SPACE HIGH, BAR LOW --------
TRANSMIT IN C39 F ORMAT ----TRANSMIT IN C128 FORMAT --TRANSMIT IN C39 ------------FULL ASCII
14