Page 21
HIGH -------------------------TRANSMIT PRE-NOISE ---------DON'T TRANSMIT PRE-NOISE --ENABLE -----------------------DISABLE ----------------------WAND EMULATION INTERFACE
IDLE STATE A N OISE TRANSMIT C128 TPRANSMIT ATTERN B EFORE FUNCTION CHAR' S LABEL TRANSMISSION
END
LOW --------------------------
-------------------------------------
Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other settings for this interface.
15
Page 22
RS-232 INTERFACE SELECTION Scan this label to enable the standard RS-232 interface.
SNI RS-232 INTERFACE SELECTION Scan this label to enable the SNI RS-232 interface.
RS-232 COMMUNICATION PARAMETERS This section contains the following RS-232 communication parameters in the order listed:
RS-232 INTERFACE
•
Baud Rate
•
Data Bits
•
Parity
•
Stop Bit(s)
•
Hardware Handshaking (CTS/RTS)
•
Software Handshaking (Xon/Xoff)
•
ACK/NAK Options
•
Intercharacter Delay
Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other settings for this interface.
16
Wasp Laser Scanner Programming Guide
Page 23
BAUD RATE Use the bar codes on this page to select the communications Baud Rate. Only one Baud Rate selection may be active at any one time. The last Baud Rate label you scan during a programming session will be the setting that is stored when you scan the END label.
SET
------------------------------------= 1200 ----------------------
BAUD RATE
= 2400 ---------------------= 4800 ---------------------= 9600 ---------------------= 19200 --------------------
END
RS-232 INTERFACE
= 38400 -------------------------------------------------------DATA FORMAT TABLE There are many possible data format configurations for an RS-232 interface. Check your host system manual to find out your system's communications requirements. This table shows the acceptable format options. Data Bits Seven Seven Seven Eight Eight Eight
Start Bit 1 1 1 1 1 1
Parity Bit(s) 0 1 1 0 0 1
Stop Bit(s) 2 1 2 1 2 1
17
Page 24
DATA FORMAT SETTINGS The bar codes on this page can be used to select the data format configuration needed to communicate with your system.
SET
------------------------------------NONE -------------------------
PARITY
EVEN -------------------------ODD -------------------------M ARK -------------------------
ONE -------------------------TWO --------------------------
DATA BITS
RS-232 INTERFACE
STOP BITS
S PACE ------------------------
SEVEN BITS -------------------
END
-------------------------------------
18
EIGHT BITS --------------------
Wasp Laser Scanner Programming Guide
Page 25
HANDSHAKING Review your system documentation to identify handshaking requirements, and use these labels to change the settings if required. The following brief descriptions explain each selection.
HARDWARE CONTROL CTS/RTS Flow Control, is hardware handshaking. The scanner activates the RTS (Ready to Send) line when it is ready to send data to the host. The scanner waits for an active Clear to Send (CTS) signal from the host before transmitting data. If hardware control is disabled, CTS/RTS communication will not take place. If the host deactivates the CTS line during data transmission, the host will receive additional characters for no more than 2msec1.
CTS/RTS Flow Control Data
Label Transmission
Disabled
Xmission
Label Transmission
Active
CTS
Inactive
CTS Scan Control Data
Label 1
Label 1
RS-232 INTERFACE
CTS Scan Control, is also a hardware control. When scan control is enabled, label transmission is disabled until CTS is asserted and de-asserted. Will not scan again until toggle Label 2
Disabled until Assert
CTS
1
De-assert
Varies slightly depending upon baud rate selected.
19
Page 26
SOFTWARE CONTROL XON/XOFF, this is software handshaking that allows the host to control data transmission. If the host sends an XOFF command to the scanner, the scanner will not send the bar code data until it receives an XON command from the host. If the host sends the XOFF command during data transmission, the host will receive additional characters for no more than 2msec1.
NOTE
Hardware/software controls are mutually exclusive. Enable only one of these features at a time, as enabling multiple controls can produce unpredictable results.
ENABLE CTS/RTS FLOW CONTROL ENABLE CTS SCAN CONTROL -ENABLE XON/ XOFF -----------DISABLE XON/X OFF ------------
END
1
20
------------------------------------DISABLE HARDWARE CONTROL --
SOFTWRE CONTROL
RS-232 INTERFACE
HARDWARE CONTROL
SET
-------------------------------------
Varies slightly depending upon baud rate selected.
Wasp Laser Scanner Programming Guide
Page 27
RS-232 ACK/NAK OPTIONS (QUICKSCAN 6000 PLUS ONLY) Several ACK/NAK parameters can be set for your QuickScan 6000 Plus scanner. Contact Informatics, Inc. if the specific ACK/NAK option you wish to set is not included in this section.
Options for RS-232 ACK/NAK are:
•
Disable ACK/NAK
•
Enable ACK/NAK for bar code transmission
•
Enable ACK/NAK for host command acknowledge
•
Enable ACK/NAK for bar code transmission and host command acknowledge.
(THESE FEATURES AVAILABLE FOR QUICKSCAN 6000 PLUS ONLY)
SET
-------------------------------------
RS-232 INTERFACE
ACK/NAK ENABLE
DISABLE ACK/NAK -------------FOR BAR CODE TRANSMISSION -----FOR HOST COMMAND ACKNOWLEDGE FOR BAR CODE TRANSMISSION -----AND H OST C OMMAND A CKNOWLEDGE END
-------------------------------------
21
Page 28
INTERCHARACTER DELAY Intercharacter Delay refers to the pause, if any, between each character before it is sent to the host. This time delay is used to control the flow of data from the scanner, but it should not be required for most applications. Use these labels to select the desired Intercharacter Delay.
SET
------------------------------------= NONE ----------------------= 10 MILLISECONDS ------------
RS-232 INTERFACE
INTERCHARACTER DELAY
= 20 MILLISECONDS -----------= 30 MILLISECONDS -----------= 40 MILLISECONDS -----------= 50 MILLISECONDS -----------= 60 MILLISECONDS -----------= 70 MILLISECONDS -----------= 80 MILLISECONDS ------------
22
Wasp Laser Scanner Programming Guide
Page 29
INTERCHARACTER
Detay
INTERCHARACTER DELAY (continued)
~ 90 mneisecons a | WAIN | ~ 100 mneisecons, - - | vill | | | | |
23
RS-232
Lu oO =< re c Lu = =
Page 30
This section contains the following PC Keyboard Wedge communication parameters in the order listed:
KEYBOARD WEDGE COMMUNICATION PARAMETERS •
Interface Selection
•
Connect to Laptop
•
Caps lock Settings
•
Country modes
•
Intercharacter Delay
Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other settings.
NOTE
If the transmission parameters are configured such that a label results in no actual data to send, the label will be accepted, beeped, and no data transmitted.
PC KEYBOARD WEDGE INTERFACE SELECTION The scanner supports ten PC Keyboard Wedge interfaces. The table below defines the different interface selections.
KEYBOARD WEDGE INTERFACE
I/F Type
PCs Supported
A B C D E F G H I J
PC/XT w/foreign keyboard AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/foreign keyboard PS/2 25 and 30 w/foreign keyboard PC/XT w/US keyboard AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/US keyboard PS/2 25 and 30 w/US keyboard IBM 3xxx w/122 keyboard IBM 3xxx w/102 keyboard PS/55 5530T w/104 keyboard NEC 9801
NOTE
We recommend that you disconnect power before plugging/unplugging cables to avoid any possibility of equipment damage.
24