Page 31
PC KEYBOARD WEDGE INTERFACE SELECTION - CONTINUED The scanner supports ten PC Keyboard Wedge interfaces. The table below defines the different interface selections.
SET
------------------------------------A ----------------------------B -----------------------------
INTERFACE (I/F) TYPE (SEE TABLE ON PREVIOUS PAGE)
C ----------------------------D ---------------------------E ----------------------------F ----------------------------G ---------------------------KEYBOARD WEDGE INTERFACE
H ---------------------------I ----------------------------J ----------------------------END
-------------------------------------
25
Page 32
PC KEYBOARD WEDGE – CONNECT TO A LAPTOP/NO KEYBOARD ATTACHED If no keyboard is attached, the scanner must provide the acknowledge signal to the PC. In this case, enable the "Laptop/No External Keyboard" mode. If a keyboard is attached, enable "Keyboard Attached". Laptop (integrated keyboard), Scan the "Laptop/No External Keyboard" label below when the scanner is connected to a laptop computer or when the scanner is operated with no external keyboard attached. PC (external keyboard), If you move the scanner to a standard PC, change the setting to "Keyboard Attached". Send Control Characters, When this feature is disabled, all ASCII characters except NUL (00h) are transmitted. Enabling this feature limits transmission of ASCII characters to the following: •
Only ASCII characters between 20h..127h, plus… - Carriage Return (CR=0Dh) - BackSpace (BS=08h) - Right Tab (HT=09h) - Left Tab (0Bh) - Esc (1Bh)
KEYBOARD WEDGE INTERFACE
SEND CONTROL CHARACTERS
CONNECT TO LAPTOP OR PC
SET
END
26
------------------------------------LAPTOP/NO EXTERNAL KEYBOARD KEYBOARD ATTACHED ----------ENABLE -----------------------DISABLE -----------------------------------------------------------
Wasp Laser Scanner Programming Guide
Page 33
CAPS LOCK Three caps lock settings are available; these are: Caps Lock Off, to send character data (to the host)in normal format.
•
Caps Lock On, to send character data (to the host) in reverse case: (a…z) = (A…Z) (A…Z) = (a…z) Use this feature if your caps lock is on.
•
Caps Lock = Shift-Lock, to send character data (to the host) in shifted case. Use this feature if your shift lock is on. For use with interface type G (122-keyboard) ONLY.
SET
-------------------------------------
CAPS LOCK OPTIONS
•
CAPS LOCK OFF -------------CAPS LOCK ON ---------------
END
KEYBOARD WEDGE INTERFACE
CAPS LOCK = SHIFT -LOCK -----------------------------------------
27
Page 34
COUNTRY MODE The following country/languages can be selected: • • • •
USA Belgium Britain Denmark
SET
• • • •
France Germany Italy Norway
• • • •
Portugal • Japanese 106-Key Spain Sweden Switzerland
------------------------------------USA ------------------------BELGIUM ----------------------
COUNTRY MODE
BRITAIN ----------------------DENMARK --------------------FRANCE ----------------------GERMANY ---------------------
KEYBOARD WEDGE INTERFACE
I TALY ------------------------NORWAY ---------------------PORTUGAL ---------------------
28
Wasp Laser Scanner Programming Guide
Page 35
COUNTRY MODE, CONTINUED
COUNTRY MODE
SPAIN ------------------------SWEDEN ----------------------SWITZERLAND -----------------JAPANESE 106-KEY -----------------------------------------------
KEYBOARD WEDGE INTERFACE
END
29
Page 36
INTERCHARACTER DELAY Intercharacter Delay refers to the pause, if any, between each character before it is sent to the host. This time delay is used to control the flow of data from the scanner, but it should not be required for most applications. Use these labels to select the desired Intercharacter Delay.
SET
------------------------------------= NONE ----------------------= 5 MILLISECONDS ------------= 10 MILLISECONDS ------------
INTERCHARACTER DELAY
= 15 MILLISECONDS -----------= 20 MILLISECONDS -----------= 25 MILLISECONDS -----------= 30 MILLISECONDS ------------
KEYBOARD WEDGE INTERFACE
= 35 MILLISECONDS -----------= 40 MILLISECONDS -----------= 45 MILLISECONDS -----------= 50 MILLISECONDS ------------
30
Wasp Laser Scanner Programming Guide
Page 37
INTERCHARACTER DELAY - CONTINUED = 55 MILLISECONDS -----------= 60 MILLISECONDS -----------= 65 MILLISECONDS ------------
INTERCHARACTER DELAY
= 70 MILLISECONDS -----------= 75 MILLISECONDS -----------= 80 MILLISECONDS -----------= 85 MILLISECONDS -----------= 90 MILLISECONDS ------------
KEYBOARD WEDGE INTERFACE
= 95 MILLISECONDS -----------= 99 MILLISECONDS -----------END
-------------------------------------
31
Page 38
LABEL TRANSMIT FORMAT CONFIGURATION ITEMS (RS-232 AND KEYBOARD WEDGE INTERFACES ONLY) If you need to send information in addition to label data, the scanner can be configured to transmit prefixes and/or suffixes as well as symbology specific identifier characters (Label I.D.).
PREFIX & SUFFIX As the examples below show, none, one or two symbology specific ASCII characters can be added to the beginning of label in addition to multiple prefix and suffix characters.
NOTE
Using this feature requires a thorough understanding of your specific system requirements.
The options available using this feature are:
LABEL TRANSMIT FORMAT CONFIG
• symbology specific (0 - 2) characters + label data PP + label data
• non-symbology specific characters (1-2) as a prefix + label data CpCp + label data
• label data + non-symbology specific characters (0-2) as a suffix label data + CsCs
• non-symbology specific characters (1-2) as a prefix + symbology specific characters (0-2) + label data CpCp + PP + label data
• symbology specific characters (0-2) + label data + nonsymbology specific characters (1-2) as a suffix PP + label data + CsCs
32
Wasp Laser Scanner Programming Guide
Page 39
non-symbology specific characters (1-2) as a prefix + label data + non-symbology specific characters (1-2) as a suffix CpCp + label data + CsCs
• non-symbology specific characters (1-2) as a prefix + symbology specific characters (0-2) + label data + non-symbology specific characters (1-2) as a suffix CpCp + PP + label data + CsCs
• non-symbology specific characters (1-2) as a prefix + label data + symbology specific characters + non-symbology specific characters used as suffixes. CpCp + label data + PP + CsCs
LABEL TRANSMIT FORMAT CONFIG
•
PP = symbology specific characters (Label I.D.) CpCp = non-symbology specific ASCII characters used as prefixes CsCs = non-symbology specific ASCII characters used as suffixes
33
Page 40
SETTING NON-SYMBOLOGY SPECIFIC PREFIX(ES) These characters will be added to the standard label format when your host system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Identify your specific system requirements before adding or modifying these settings, then... 1.
Look at the ASCII chart shown on page 38 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as prefixes. For example, if you are going to send two prefix characters as 'STX' (start transmit) and 'SP' (Space). The ASCII chart shows that 'STX' equals 02hex and 'SP' equals 20 hex.
2.
Scan the SET label.
3.
Scan the SET PREFIX label on this page.
4.
Scan the digits that correspond to the Hex Values. For the example in step four, scan 0, 2, 2, 0.
NOTE
If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone (six rapid beeps) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. 5.
Scan END. You have added a two character prefix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.
SET
-------------------------------------
LABEL TRANSMIT FORMAT CONFIG
SET PREFIX ------------------GO TO THE SECOND PAGE FOLLOWING THIS AND SCAN THE APPROPRIATE CHARACTERS BEFORE SCANNING THE END LABEL TO EXIT PROGRAMMING SESSION .
34
Wasp Laser Scanner Programming Guide