The text of a manual · part 5 of 10
Laser Programming Guide, pages 41 to 50
Pages 41 to 50 of 100
The original document is the PDF (674 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Wasp WLS-9000
Page 41
SETTING NON-SYMBOLOGY SPECIFIC SUFFIX(ES) These characters will be added to the standard label format when your system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Suffix characters follow the label data. Identify your specific system requirements before adding or modifying these settings, then... 1.
Look at the ASCII chart shown on page 38 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as suffixes. For example, if you are going to send two suffix characters as 'BEL' (sound host tone) and 'ETX' (end transmission). The ASCII chart shows that 'BEL' equals 07 hex and 'ETX' equals 03hex.
2.
Scan the SET label.
3.
Scan the SET SUFFIX label on this page.
4.
Scan the digits that correspond to the Hex Values. For the example in step five, scan 0, 7, 0, 3.
NOTE
If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone (six rapid beeps) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. 5.
Scan END. You have added a two character suffix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.
-------------------------------------
LABEL TRANSMIT FORMAT CONFIG
SET
SET SUFFIX ------------------GO TO THE NEXT TWO PAGES AND SCAN THE APPROPRIATE CHARACTERS BEFORE SCANNING THE END LABEL TO EXIT PROGRAMMING SESSION .
35
Page 42
SETTING A SINGLE CHARACTER PREFIX OR SUFFIX To set one ASCII character as a prefix or suffix, follow steps one through four on the previous two pages (select prefix or suffix), then... 1.
Scan the two digit Hex Code for that character. (e.g. 03, 8F, ...FF) NOTE
If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone (six rapid beeps) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. 2.
Scan the ONE CHARACTER ONLY label on the following page.
3.
Scan the END label.
You have set a single character prefix or suffix.
SETTING PREFIX AND/OR SUFFIX CHARACTERS NOTE
You must scan the SET label and either the SET PREFIX or SET SUFFIX label before using the labels on this page.
0 ----------------------------1 ----------------------------2 ----------------------------LABEL TRANSMIT FORMAT CONFIG
3 ----------------------------4 -----------------------------
36
Wasp Laser Scanner Programming Guide
Page 43
5 ----------------------------6 ----------------------------7 ----------------------------8 ----------------------------9 ----------------------------A ----------------------------B ----------------------------C ----------------------------D ---------------------------E ----------------------------F -----------------------------
END
LABEL TRANSMIT FORMAT CONFIG
ONE CHARACTER O NLY ---------------------------------------------
37
Page 44
ASCII CHARACTER SET The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting symbology specific label identifiers, as well as enabling custom prefix and suffix characters.
LABEL TRANSMIT FORMAT CONFIG
38
ASCII C HAR.
HEX V ALUE
ASCII C HAR.
HEX V ALUE
ASCII C HAR.
HEX V ALUE
ASCII C HAR.
HEX V ALUE nul soh stx etx eot enq ack bel bs ht lf vt ff cr so si dle dc1 dc2 dc3 dc4 nak syn etb can em sub esc fs gs rs us
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F sp ! " # $ % & ' ( ) * + ' . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ del
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
Wasp Laser Scanner Programming Guide
Page 45
SETTING SYMBOLOGY SPECIFIC LABEL IDENTIFIERS (LABEL I.D.) Symbology-specific label identifiers comprise one or two ASCII characters that can precede or follow barcode label data as it is transmitted to the host. The host uses these characters as a means of distinguishing between symbologies. Industry standards have been established for symbology-specific label identifiers, and are listed in the table below. Most scanners will have factory default identifiers preset to these standards. UPC-A ------------------------ 'A' UPC-E ------------------------ 'E' EAN-8 ----------------------- 'FF' EAN-13 ----------------------- 'F' UPC-A (2 add-on) --------- 'A' UPC-A (5 Add-on) --------- 'A' UPC-A (8 Add-on) ---------- 'A' UPC-E (2 add-on) --------- 'E' UPC-E (5 Add-on) --------- 'E' UPC-E (8 Add-on) ---------- 'E' EAN-8 (2 add-on) --------- 'FF'
EAN-8 (5 Add-on) --------- 'FF' EAN-8 (8 Add-on) ---------- 'FF' EAN-13 (2 add-on) -------- 'F' EAN-13 (5 Add-on) -------- 'F' EAN-13 (8 Add-on) --------- 'F' Code 39 ---------------------- '*' Codabar --------------------- '%' Interleaved.2 of 5 ----------- 'i' Code 93 ---------------------- '&' Code 128 -------------------- '#' MSI/Plessey ---------------- '@'
TABLE 1. INDUSTRY STANDARD LABEL IDENTIFIERS (ALL ARE PREFIXES) To set symbology-specific label identifiers: 1.
Look at the ASCII chart shown on the previous page and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as identifiers. You will also need to determine whether the character(s) will need to be sent as a prefix or a suffix.
2.
Scan the SET label below.
3.
Scan either the TRANSMIT LABEL I.D. AS PREFIX or TRANSMIT LABEL I.D. AS SUFFIX, depending on your requirements. For our example, the 'transmit as prefix' label would be scanned.
39
LABEL TRANSMIT FORMAT CONFIG
For example: You need to change the label identifier prefix for UPC-A to 'A1'.
Page 46
SETTING SYMBOLOGY SPECIFIC LABEL IDENTIFIERS (LABEL I.D.) CONTINUED 4.
Scan the label representing the symbology whose label identifier you wish to modify. In our example, we would scan the 'UPC-A' symbology label.
5.
Identify and scan the digits that correspond to the Hex Values. The hex values from the ASCII chart that correspond to 'A1' from our example are as follows: 41hex = 'A', and 31 hex = '1'. Thus, we would scan digit programming labels in this order: 4, 1, 3, 1.
6.
Scan the END label. In our example, you have changed the default label identifier prefix for UPC-A from 'A' to 'A1'.
SET
------------------------------------DISABLE LABEL I.D. CONTROL ---TRANSMIT LABEL I.D. AS PREFIX TRANSMIT LABEL I.D. AS SUFFIX -
LABEL TRANSMIT FORMAT CONFIG
40
Wasp Laser Scanner Programming Guide
Page 47
LABEL I.D. SYMBOLOGY SELECTION UPC-A ---------------------UPC-A W /2 DIGIT ADD-ON ---UPC-A W /5 DIGIT ADD-ON ----
UPC-E ---------------------UPC-E W/2 DIGIT ADD-ON ---UPC-E W/5 DIGIT ADD-ON ---UPC-E W/C128 ADD -ON ----EAN-8 ---------------------EAN-8 W /2 DIGIT ADD -ON ----EAN-8 W /5 DIGIT ADD -ON ----LABEL TRANSMIT FORMAT CONFIG
SET SYMBOLOGY SPECIFIC LABEL IDENTIFIER FOR:
UPC-A W /C128 ADD-ON -----
EAN-8 W /C128 ADD-ON ----EAN-13 ---------------------
41
Page 48
LABEL I.D. SYMBOLOGY SELECTION CONTINUED EAN-13 W/2 DIGIT ADD-ON ---
SET SYMBOLOGY SPECIFIC LABEL IDENTIFIER FOR:
EAN-13 W/5 DIGIT ADD-ON --EAN-13 W/C128 ADD-ON --CODE 39 --------------------CODABAR ---------------------I NTERLEAVED 2 OF 5 ----------STANDARD 2 OF 5 ------------CODE 93 --------------------CODE 128 -------------------MSI/PLESSEY ---------------END
-------------------------------------
LABEL TRANSMIT FORMAT CONFIG
42
Wasp Laser Scanner Programming Guide
Page 49
HOW TO SET SINGLE CHARACTER LABEL I.D. If you only want a single character identifier, follow this modified procedure for setting label identifier. 1.
Look at the ASCII chart shown on page 38 and identify the ASCII character and the corresponding Hex Code for the ASCII character you will use as the symbology specific identifier.
2.
Scan the SET label.
3.
Scan the label identifier label for the symbology identifier that you are going to change. As an example, assume that you want to change the label identifier for EAN-8 from the default setting FF to the ASCII value 8. Scan the Set Symbology Specific Label Identifier barcode for EAN-8.
5.
Identify the hex value that correspond to the ASCII character. In this example '8' equals 38 hex. Simply follow the hex value for '8' (38 hex) with the One Character Only label. This tells the scanner that '8' is a single digit label identifier.
6.
Scan the barcodes values. For the example in step five, scan 3, 8, One Character Only on the following two pages.
NOTE
If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone (six rapid beeps) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. Scan the END label.
LABEL TRANSMIT FORMAT CONFIG
7.
You have changed the default label identifier for EAN-8 from 'FF' to '8'.
43
Page 50
DISABLING LABEL I.D. FOR A SPECIFIC SYMBOLOGY This procedure is the same as setting a single character symbology identifier, except you should scan two zeros and the One Character Only labels before scanning the END label.
SYMBOLOGY SPECIFIC LABEL IDENTIFIERS CHARACTERS Use the labels on this page to change or modify symbology identifiers.
0 ----------------------------1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------7 -----------------------------
LABEL TRANSMIT FORMAT CONFIG
8 ----------------------------9 -----------------------------
44
Wasp Laser Scanner Programming Guide