Page 81
Most scanners shipped from the factory are set to read variable length labels for Codabar. If you switch from variable to fixed length labels, the factory set fixed label lengths are 14 and 08. Follow the steps below to change these defaults. ENABLE FIXED 1. Identify the fixed length settings you want to make. 2.
Scan the SET label.
3.
Scan the SET FIRST FIXED LENGTH label.
SETTING LENGTHS If you are setting a length less than ten, you must scan a zero first and then the length digit (02, ...09). 4.
Set the first fixed length label by scanning the correct digits from the next page. The selectable range is from 03 to 50 (IBM Interface the range is 03 to 32 digits). If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length, scan the NO SECOND FIXED LENGTH label below and skip to step seven.
SET
-------------------------------------
CODABAR
SET FIRST FIXED LENGTH -----SET SECOND FIXED LENGTH ---NO SECOND FIXED LENGTH -----
75
SYMBOLOGY SELECTION
CODABAR FIXED LENGTH
Page 82
Scan the SET SECOND FIXED LENGTH label.
6.
Set the second fixed label length by scanning the correct digits from this page. The selectable range is from 03 to 50 (IBM Interface the range is from 03 to 32 digits).
7.
Scan the END label to complete the procedure.
0 ----------------------------1 ----------------------------2 ----------------------------CODABAR SET FIXED LENGTHS
SYMBOLOGY SELECTION
5.
3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------7 ----------------------------8 ----------------------------9 -----------------------------
END
76
-------------------------------------
Wasp Laser Scanner Programming Guide
Page 83
MSI/Plessey Check Digit options include: Check Digit Calculation, calculate the Check Digit to verify the labels contents have been read correctly. If you enable this feature, your bar codes must include a Check Digit. You may also choose to transmit or not transmit the Check Digit. Transmit Check Digit, enable or disable transmission of MSI/Plessey Check Digit(s). Number of Check Digits, specify either one or two Check Digits.
SET
------------------------------------CALCULATE CHECK DIGIT -------
MSI/PLESSEY CHECK DIGIT SELECTIONS
DON'T CALCULATE CHECK DIGIT TRANSMIT CHECK D IGIT -------DON'T TRANSMIT CHECK DIGIT ONE CHECK D IGIT ------------TWO CHECK DIGITS -----------END
-------------------------------------
77
SYMBOLOGY SELECTION
MSI/PLESSEY CHECK DIGIT
Page 84
You have the option of requiring MSI/Plessey labels to have one or two fixed length(s). To set fixed length(s) for MSI/Plessey labels: 1.
Identify the fixed length setting(s) you wish to make. Fixed lengths can be set from four to fifteen, including check character(s).
2.
Scan the SET label.
3.
Scan the ENABLE MSI/PLESSEY FIXED label.
4.
Scan the SET FIRST FIXED LENGTH label.
5.
Set the first fixed label length by scanning the correct digits on the following page. If you are setting a length less than ten, you must scan a zero first and then the length digit (e.g., 04, 06, 09). If a second fixed length is not needed, skip to Step 8.
6.
If a second fixed length is desired, scan the SET SECOND FIXED LENGTH label.
7.
Set the second fixed label length by scanning the correct digits on the following page. Remember, if you're setting a length less than ten, you must scan a zero first and then the length digit.
8.
Scan the END label.
SET MSI/PLESSEY ENABLE FIXED LENGTHS
SYMBOLOGY SELECTION
MSI/PLESSEY FIXED LENGTH
78
------------------------------------ENABLE MSI/PLESSEY FIXED --DISABLE MSI/PLESSEY FIXED --
Wasp Laser Scanner Programming Guide
Page 85
SYMBOLOGY SELECTION
SET FIRST FIXED LENGTH -----SET SECOND FIXED LENGTH ---NO SECOND FIXED LENGTH ----0 -----------------------------
MSI/PLESSEY SET FIXED LENGTHS
1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------7 ----------------------------8 ----------------------------9 ----------------------------END
-------------------------------------
79
Page 86
GENERAL FEATURES The following section contains the general features that are common to all interfaces. These features allow modification of the scanner's behavior to accomodate user preferences.
GENERAL FEATURES
GOOD READ BEEPER SETTINGS These labels provide options for the scanner's audible 'beep' signal. Audible Signal - enables/disables the beep upon completion of a good read. NOTE
It is strongly recommended that this feature remain enabled, as the good read beep provides the best scanning status feedback to the user. Error tones are always enabled and cannot be disabled.
Power-up Beep - when enabled, beeps upon scanner power up. Beeper Volume - allows setting of the beeper to NORMAL or HIGH volume. Good Read Beep Duration - can be adjusted to short (100msec), medium (250msec), or long (500msec) durations. When to Beep - may be programmed to announce a 'good read' upon completion of one of the following events:
80
•
Decode of a bar codes label
•
Transmission from the scanner to the host
•
CTS activation at the host terminal (RS-232 models ONLY)
Wasp Laser Scanner Programming Guide
Page 87
-------------------------------------
GENERAL FEATURES
OFF --------------------------
POWER-UP BEEP
ON --------------------------ENABLE ------------------------
BEEPER VOLUME
AUDIBLE SIGNAL
SET
NORMAL -----------------------
DISABLE -----------------------
LOUD -------------------------
BEEP D URATION
SHORT -----------------------M EDIUM ----------------------LONG -------------------------
WHEN TO BEEP
AFTER DECODE ---------------AFTER LABEL X-MISSION -------
END
-------------------------------------
AFTER CTS ACTIVATION -------
81
Page 88
READ VERIFICATION Wasp Laser programming has been improved to allow selection of read verification "minimum read" requirements by symbology type, as well as universally. This means that the scanner needn't waste valuable time verifying high-confidence symbologies, while offering the security of multiple read verification on less reliable codes.
GENERAL FEATURES
NOTE The more times the scanner is required to read and compare the bar codes data, the longer it will take to complete a good read cycle.
UNIVERSAL READ VERIFICATION To set read requirements universally (read requirements will be in effect for all symbologies), scan one of the selections below for one, two, three or four reads required before a bar code's data can be transmitted to the host.
NOTE DO NOT scan SET or END bar codes when programming these features. Programming mode is automatically entered and exited when one of the four bar codes below are scanned.
UNIVERSAL READ VERIFICATION
VERIFY 1 READ, ALL SYMBOLOGIES
82
VERIFY 2 READS, ALL SYMBOLOGIES
VERIFY 3 READS, ALL SYMBOLOGIES
VERIFY 4 READS, ALL SYMBOLOGIES
Wasp Laser Scanner Programming Guide
Page 89
READ VERIFICATION BY SYMBOLOGY 1.
Scan the SET label.
2.
Scan one symbology label below to select the symbology to be verified.
3.
Scan the label on the following page representing the amount of times you wish a bar code label of that symbology type to be read before transmission to the host.
4.
Repeat steps one through three above until read verification has been selected for all symbologies you desire to be verified.
5.
Scan the END label.
SET
GENERAL FEATURES
To set the minimum read requirement for a desired symbology:
-------------------------------------
READ VERIFICATION SYMBOLOGY TYPE
VERIFY UPC-A --------------VERIFY UPC-E --------------VERIFY EAN-8 --------------VERIFY EAN-13 -------------VERIFY INSTORE LABEL1 --------------VERIFY CODE 39 --------------
1
Instore labels are UPC-A bar codes with a number system character of 2 or 4, and EAN-8 and EAN-13 bar codes with a Flag 1 character of 2.
83
Page 90
VERIFY STANDARD 2 OF 5 -----VERIFY CODABAR --------------VERIFY CODE 93 -------------VERIFY CODE 128 -----------VERIFY MSI/P LESSEY ---------
VERIFY READS (APPLIES TO ALL SYMBOLOGIES ABOVE)
GENERAL FEATURES
READ VERIFICATION SYMBOLOGY TYPE
VERIFY INTERLEAVED 2 OF 5 ----
END
84
ONE READ -------------------TWO R EADS ------------------THREE READS ----------------FOUR R EADS ------------------------------------------------------
Wasp Laser Scanner Programming Guide