The text of a manual · part 8 of 10
Laser Programming Guide, pages 71 to 80
Pages 71 to 80 of 100
The original document is the PDF (674 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Wasp WLS-9000
Page 71
All interfaces that are shipped with the standard factory configuration are set to read variable length labels. If you switch from variable to fixed length labels (by disabling variable lengths on the previous page), the default fixed label lengths are 14 digits and 8 digits. Follow the steps below to change these defaults. All fixed length settings for Interleaved 2 of 5 must be an even number. SET FIXED 1. Identify the fixed length settings you want to make. 2.
Scan the SET label.
3.
Scan the ENABLE FIRST FIXED barcode.
SETTING FIXED LENGTHS If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 06, 08). 4.
Set the first fixed label length by scanning the correct digits from the next two pages. If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length scan the NO SECOND FIXED LENGTH below and skip to step seven.
5.
Scan the SET SECOND FIXED label.
6.
Set the second fixed label length by scanning the correct digits from this page.
7.
Scan the END label to complete the procedure.
SETTING MINIMUM LABEL LENGTH 1. Identify the minimum length setting you want to make. The selectable range is 00 to 50 characters (Note: For the IBM Interface the range is 00 to 32 characters). 2.
Scan the SET label.
3.
Scan the SET MINIMUM LABEL LENGTH barcode.
If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 06, 08). 4.
Set the minimum label length by scanning the correct digits from the next two pages
5.
Scan the END label.
65
SYMBOLOGY SELECTION
SETTING INTERLEAVED 2 OF 5 FIXED AND MINIMUM LABEL LENGTHS
Page 72
------------------------------------SET FIRST FIXED LENGTH -----SET SECOND FIXED LENGTH ----
INTERLEAVED 2 OF 5 FIXED AND MINIMUM LABEL LENGTHS
SYMBOLOGY SELECTION
SET
NO SECOND FIXED LENGTH ----SET MINIMUM LABEL LENGTH --0 ----------------------------1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------6 ----------------------------8 -----------------------------
END
66
-------------------------------------
Wasp Laser Scanner Programming Guide
Page 73
The Standard 2 of 5 symbology has the following programmable features: Check Digit, calculate the Check Digit to verify that the Check Digit contained in the bar code label is correct. If you enable this feature, your bar codes must contain a Check Digit. You may also choose to transmit or not transmit the Check Digit independent of whether the Check Digit is calculated by the scanner. The Transmit Check Digit will have no effect unless the Compute Check Digit feature is enabled. If you choose Don’t Compute Check Digit, the scanner sends the Check Digit encoded in the bar code without verifying its accuracy. If you choose both Compute Check Digit and Don't Transmit Check Digit, the scanner will remove the Check Digit's contents before sending the bar code data to the host. The Transmit Check Digit option has no effect unless the Compute Check Digit option is enabled. Label Format, provides the selection between fixed or variable length labels. If your application has labels with specific fixed lengths, we recommend selecting fixed lengths to improve read rate and avoid short reads. You can select any valid number of digits for reading specific length labels only. Read the following details for specific Standard 2 of 5 limits.
STANDARD 2 OF 5 LABEL LENGTHS Standard 2 of 5 Minimum Label Length, set the minimum label length required for Standard 2/5 labels (not including the check character). This feature is provided to ignore small label segments, reducing the possibility that a portion of a good label is incorrectly seen as an entire label. Variable Length, If you select variable length, the scanner will recognize labels with a number of digits between 01 and 50 digits. (Note: for IBM Interface the number of recognized labels is between 01 and 32 digits). Fixed Length, If you select fixed length, there are three labels for programming your scanner to read either one or two fixed lengths. The labels are: •
Set First Fixed Length, use this label to instruct the scanner that the next two programming labels you scan will define the first fixed label length. This setting can be any number of digits between 01 and 50 digits (IBM Interface: 01 to 32 digits).
67
SYMBOLOGY SELECTION
STANDARD 2 OF 5
Page 74
Set Second Fixed Length, use this label to instruct the scanner that the next two programming labels you scan will define the second fixed label length. Again, this setting can be any number of digits between 01 and 50 digits. (IBM Interface: between 01 and 32 digits).
•
No Second Fixed Length, scan this label after setting the first fixed length to instruct the scanner to recognize only the label length chosen as the first fixed length.
CHECK DIGIT AND VARIABLE LENGTH LABEL SELECTIONS These programming labels determine whether you compute and send the check digit contents. If you want to set the scanner to read only fixed length labels, follow the procedures on the pages immediately following.
SET
-------------------------------------
CHECK DIGIT
DON'T COMPUTE ---------------COMPUTE ---------------------DON'T TRANSMIT --------------TRANSMIT --------------------VARIBLE LENGTH L ABELS
SYMBOLOGY SELECTION
•
END
68
ENABLE -----------------------DISABLE -----------------------------------------------------------
Wasp Laser Scanner Programming Guide
Page 75
All interfaces that are shipped with the standard factory configuration are set to read variable length labels. If you switch from variable to fixed length labels, the default fixed label lengths are 14 digits and 8 digits. Follow the steps below to change these defaults. SET FIXED 1. Identify the fixed length settings you want to make. 2.
Scan the SET label.
3.
Scan the ENABLE FIRST FIXED bar code.
SETTING FIXED LENGTHS If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 07, 08). 4.
Set the first fixed label length by scanning the correct digits from the next two pages. If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length scan the NO SECOND FIXED LENGTH below and skip to step seven.
5.
Scan the SET SECOND FIXED label.
6.
Set the second fixed label length by scanning the correct digits from this page.
7.
Scan the END label to complete the procedure.
SETTING MINIMUM LABEL LENGTH 1. Identify the minimum length setting you want to make. The selectable range is 01 to 50 characters. (Note:For the IBM Interface the range is 01 to 32 characters). 2.
Scan the SET label.
3.
Scan the SET MINIMUM LABEL LENGTH bar code.
If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 07, 08). 4.
Set the minimum label length by scanning the correct digits from the next two pages.
5.
Scan the END label.
69
SYMBOLOGY SELECTION
SETTING STANDARD 2 OF 5 FIXED AND MINIMUM LABEL LENGTHS
Page 76
-------------------------------------
SET FIRST FIXED LENGTH -----SET SECOND FIXED LENGTH ---STANDARD 2 OF 5 FIXED AND MINIMUM LABEL LENGTHS
SYMBOLOGY SELECTION
SET
NO SECOND FIXED LENGTH ----SET MINIMUM LABEL LENGTH --0 ----------------------------1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------5 ----------------------------6 -----------------------------
70
Wasp Laser Scanner Programming Guide
Page 77
Stanparp 2 oF 5 Fixep ann
Minimum Laser Lenetus a {TIN a tM a IM
71
> oS So, So co = > (7)
2 J = o Lu, _ Lu “a
Page 78
SYMBOLOGY SELECTION
CODABAR OPTIONS The Codabar symbology has the following programmable features: Check Digit, calculate the Check Digit to verify the label's contents have been read correctly. If you enable this feature, your bar codes must include a Check Digit. You may also choose to transmit or not transmit the Check Digit. Start/Stop Characters, you can choose either Send or Don't Send depending on your host's interface requirement. Start/Stop Format, if you need to send the Start/Stop characters, there are four standard format options that you can select from; ABCD/TN*E, ABCD/ABCD, abcd/tn*e, or abcd/abcd. This setting must match your system requirements. If you select one of these options, it determines how the ASCII characters A, B, C, D that are used for Start/Stop characters, will be translated before being sent to the host. Start/Stop Match, the requirement that the Start and Stop characters must match (be identical) can be enabled or disabled. Label Format, provides the selection between fixed or variable length labels. If your application has labels with specific fixed length, we recommend selecting fixed lengths to improve read rate. If you select variable length, the scanner will recognize labels with between 2 and 47 digits (not including the optional check digit). Note: For IBM Interface: between 2 and 32 digits. Set First Fixed Length, if you select fixed length, use this feature to set a first fixed label length to a setting between 03 and 50 digits. (IBM Interface: between 03 and 32 digits). Set Second Fixed Length, if you select fixed length, use this feature to set a second fixed label length to a setting between 03 and 50 digits. (IBM Interface: between 03 and 32 digits). No Second Fixed Length, scan this label after setting the first fixed length to instruct the scanner to recognize only the label length chosen as the first label length. Gap Check, allows the scanner to combine two label halves printed in close proximity to each other that may have been printed at different times and perhaps different locations.
72
Wasp Laser Scanner Programming Guide
Page 79
These programming labels determine whether you compute and send the check digit contents and enables variable length. If you want to set the scanner to read only fixed length labels, follow the procedures on the following pages.
SET
-------------------------------------
CHECK DIGIT
DON'T COMPUTE ---------------COMPUTE ---------------------DON'T TRANSMIT ---------------
GAP CHECK
VARIABLE LENGTH LABELS
T RANSMIT ---------------------
END
E NABLE -----------------------DISABLE ----------------------E NABLE -----------------------DISABLE -----------------------------------------------------------
73
SYMBOLOGY SELECTION
CODABAR CHECK DIGIT & VARIABLE LENGTH
Page 80
These bar codes allow you to set the Start/Stop character format and transmission. Refer to your host user's manual to identify your system requirements, then use these labels to select which characters are transmitted.
SET
------------------------------------M ATCH NOT REQUIRED ----------
START/S TOP FORMAT & TRANSMISSION SPECIFICATIONS
SYMBOLOGY SELECTION
CODABAR START/STOP CHARACTER
M ATCH REQUIRED -------------DON'T TRANSMIT -------------TRANSMIT1 -------------------FORMAT = ABCD/TN*E ----FORMAT = abcd/tn*e ------FORMAT = ABCD/ABCD ---FORMAT = abcd/abcd ------
END 1
74
-------------------------------------
Choosing Transmit Start/Stop characters requires selecting one of these four data format selections: ABCD/TN*E, abcd, tn*e, ABCD/ABCD, or abcd/abcd. Refer to Appendix A, Standard Factory Settings, to identify the default setting for your scanner's interface type.
Wasp Laser Scanner Programming Guide