What is in it
Technical description of the Leuze electronic BCL 8, a very small fixed-mount laser bar code reader with an integrated decoder, in versions with front or side beam exit. It covers safety notices, the device and standalone operation with the MA 8 connector unit, specifications, LED indicators, dimension drawings and reading fields, accessories, mounting and wiring of the switching input and output, commissioning, parameter sets, the BCLConfig software, key parameters, online commands and maintenance.
Its parts
- General Information
- Safety Notices
- Description
- Specifications
- Accessories / Order Designation
- Installation
- Commissioning
- Operation
- Communicating with the Device
- Important Parameters
- Online commands
- Maintenance
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is the Leuze electronic technical description for the BCL 8 bar code reader with integrated decoder and its optional MA 8 connector unit. It covers safety, specifications, LED indicators, accessories with part numbers, mounting, wiring the 5-pin connector and the switching input or output, commissioning, error handling and parameter setup with the BCLConfig software.
- Device
- Laser bar code scanner with integrated decoder in a very small housing p. 10
- Interface
- RS 232, 4800 to 57600 Bd p. 12
- Power
- 4.9 to 5.4 VDC, max. 250mA; 2W power supply unit recommended p. 12
- Connector pinout
- Pin 1 +5V DC, pin 2 RS 232 TxD, pin 3 GND, pin 4 RS 232 RxD, pin 5 SW IN/OUT p. 25
- Code types
- 2/5 Interleaved, Code 39, Code 128, EAN 128, EAN/UPC, EAN Addendum, Codabar, Pharma Code, Code 93 p. 12
- Scanning
- 600 scans/s; resolution 0.150 to 0.5 mm (6 to 20 mil) p. 12
- Switching I/O
- 1 switching input 5VDC or 1 switching output 5 to 30V, 20mA, set with BCLConfig p. 12, 26
- Connector unit
- MA 8, Part No. 500 40091: 1 switching input or output, 24VDC, M12 connections p. 19, 20
- Mounting devices
- BT 8-0 (500 36196); BT 8-D10, BT 8-D12, BT 8-D14 for 10, 12, 14 mm rods (500 35017, 500 35018, 500 35019) p. 21
- Dovetail mounts
- UMS 8, UMS 8.1 (turning) and UMS 8.2 (turning and inclinable) for 10, 12, 14 mm rods, Part No. 500 35020 to 500 35028 p. 19, 21
- Software
- BCLConfig programming software, download from www.leuze.de p. 19
- Dimensions
- Front beam exit 48 x 40.3 x 15 mm; side beam exit 48 x 58 x 17.4 mm p. 13
- Environment
- 0 to +40°C operating, -20 to +60°C storage; max. 90% relative humidity, non-condensing p. 13
- Housing
- Sealed diecast zinc metal housing, IP 67 p. 13, 25
What this manual walks you through
- Reading the status and decode LEDs p. 13
- Choosing mounting devices and the MA 8 connector unit p. 19, 20, 21
- Wiring the switching input (active low or inverted) or the switching output p. 26, 27
- Running the power-on function test p. 29
- Setting code type and code length and understanding parameter sets p. 30
- Handling warnings and serious errors p. 32
- Installing the BCLConfig software p. 33
Good to know
- The manual states the laser is class 2 per EN 60825-1; never look directly into the beam. p. 8
- The housing is sealed and must not be opened. p. 25
- Do not load the switching output with more than 20mA at +5 to 30VDC. p. 27
- Use in rooms with explosive atmospheres or for medical purposes is not permitted. p. 7
- Error, warning and status messages come only over the RS 232 interface. p. 32
Questions this manual answers
What is the pinout of the Leuze BCL 8 connector?
Pin 1 +5V DC, pin 2 RS 232 TxD, pin 3 GND, pin 4 RS 232 RxD and pin 5 the switching input or output. p. 25
What supply voltage does the BCL 8 need?
4.9 to 5.4 VDC at up to 250mA; a 2W power supply unit is recommended. p. 12
How do I trigger a BCL 8 read with the switching input?
In the default active-low setting, connect SW IN/OUT (pin 5) to GND (pin 3), with a 2.2 k pull-up resistor fitted externally. p. 26
What software configures the BCL 8?
BCLConfig, which is on the installation CD and can be downloaded from www.leuze.de. p. 19, 33
What is the Leuze MA 8?
A connector unit that simplifies BCL 8 wiring, with M12 connections for the reader, the switching input or output, and RS 232 plus 24VDC supply. p. 20