This is the Leuze electronic data sheet for the BCL 8, a compact single-line laser bar code reader with an RS 232 interface. It gives the optical, electrical, mechanical and environmental specifications, an order guide for the M optics and N optics versions with front or lateral beam exit, and reading field curves.
- Device
- Single-line laser bar code reader p. 1, 2
- Scanning rate
- M optics (medium density): 600 scans/s; N optics (high density): 500 scans/s p. 3
- Interface
- RS 232, 4800 to 57600 Bd, 7 or 8 data bits p. 1, 2
- Power
- 4.75 to 5.5 VDC (PELV), max. 250mA; 2W power supply unit recommended p. 2
- Code types
- 2/5 Interleaved, Code 39, Code 128, EAN 128, EAN/UPC, EAN Addendum, Codabar, Pharma Code, Code 93 p. 2
- Connection
- M12 turning connector, 5-pin, or fixed 2 m cable p. 1, 2
- Resolution
- M optics: 0.150 to 0.5 mm (6 to 20 mil); N optics: 0.127 to 0.4 mm (5 to 16 mil) p. 2
- Switching I/O
- 1 switching input 5VDC or 1 switching output 5 to 30V, 20mA p. 2
- Light source
- Laser diode, 650 nm, rotating polygon wheel p. 2
- Beam exit
- At the front, or on the side with a deflection mirror (105°) p. 2
- Dimensions
- Front beam exit 48 x 40.3 x 15 mm; side beam exit 48 x 58 x 17.4 mm p. 2
- Housing
- Diecast zinc metal, IP 67 p. 1, 2
- Service interface
- RS 232 fixed at 9600 Bd, 8 data bits, no parity, 1 stop bit p. 2
- Accessories
- Cables (KB ...), mounting systems (BT ...), modular connector units MA ... p. 1
What this sheet walks you through
- Comparing M optics and N optics reading fields at front and lateral beam exit p. 3
- Choosing a version from the order guide p. 2
- Status LED and decode LED meanings p. 2
- Dimensions and electrical connection drawing p. 1
Good to know
- The data sheet states that for UL applications it is for use in NEC class 2 circuits only. p. 2
- The data sheet states the laser is class 2 according to EN 60825-1. p. 2
Questions this sheet answers
What power supply does the Leuze BCL 8 need?
4.75 to 5.5 VDC (PELV) at up to 250mA; the data sheet recommends a 2W power supply unit. p. 2
Which bar codes can the BCL 8 read?
2/5 Interleaved, Code 39, Code 128, EAN 128, EAN/UPC, EAN Addendum, Codabar, Pharma Code and Code 93. p. 2
What is the difference between BCL 8 M optics and N optics?
M optics is for medium density codes at 600 scans/s; N optics is for high density codes at 500 scans/s. p. 3
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
BCL 8Bar code readerPart no.: 501 04864Dimensioned drawingRS 232 5V DC
! Scanning rate 600scans/s (M optics) ! Automatic detection of code type and code quality ! Parameters are stored fail-safe ! Reference code comparison function ! autoReflAct ! RS 232 interface ! Switching input or switching output ! M12 turning connector or cable connection(2m) ! Simple mounting and fastening
B1 B2
We reserve the right to make changes • 8_e03gb.fm
IP 67IEC 60068...B1 B2IEC 61326...
Accessories: (available separately)
! Cable (KB …) ! Mounting systems (BT …) ! Modular connector units MA … (see separate data sheet)
Leuze electronic GmbH + Co. KG info@leuze.de • www.leuze.com
A B C D
Turning connector, 90° Indicator LEDs (B1: status LED, B2: decode LED) Laser beam Optical axis
Electrical connection
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
BCL 8 ... - 09
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
BCL 8 Specifications
Tables Status LED
Optical data Light source Scanning rate Resolution Beam deflection Beam exit Read distance Laser Code types Software features
laser diode 650nm M optics: 600 scans/s N optics: 500 scans/s M optics: m = 0.150 … 0.5mm / 6 … 20mil, N optics: m = 0.127 … 0.4mm / 5 … 16mil by means of rotating polygon wheel at front, alternatively on the side with deflection mirror (105°) see reading fields class 2 acc. to EN 60825-1, class II acc. to 21 CFR 1040.10 with Laser Notice No. 50 2/5 Interleaved, Code 39, Code 128, EAN 128, EAN/UPC, EAN Addendum, Codabar, Pharma Code, Code 93 selectable output format, autoConfig, reference code comparison, multiple read, real time decoding, adjustment mode, control of switching input or switching output, etc.
Electrical data Interface type Baud rate Data formats Protocols Service interface Ports LEDs Operating voltage Current consumption
RS 232 4800 … 57600Bd data bits: 7, 8 parity: none, even, odd stop bit: 1, 2 framing protocol with/without handshake software handshake X ON / X OFF RS 232 with fixed data format: 9600Bd, 8 data bits, no parity, 1 stop bit STX "Data", CR, LF 1 switching input 5VDC or 1 switching output 5 … 30V, 20mA 1 device status, 1 read status 4.75 … 5.5VDC (PELV) 1) max. 250mA (2W power supply unit recommended)
Colour Green, flashing Green, continuous light Red flashing (200ms) Red, continuous light Orange flashing (200ms)
Meaning Initialisation phase Ready Warning Error, no function Service operation
Decode LED Colour Green (200ms) on Red (200ms) off Orange, continuous light
Meaning Reading successful No reading result Reading gate active
Mechanical data Housing Protection class Dimensions (WxHxD) Weight Connection type
metal (diecast zinc) IP 67 beam exit at front: 48 x 40.3 x 15mm³ beam exit on the side: 48 x 58 x 17.4mm³ 70g M12 connector, 5-pin, turning or fixed cable, 2m long, 5 x 0.25mm2
Remarks
Environmental data Ambient temp. (operation/storage) Air humidity Vibration Shock Electromagnetic compatibility Conformity
0°C … +40°C/-20°C … +60°C max. 90% rel. humidity, non-condensing IEC 60068-2-6, test FC IEC 60068-2-27, test Ea EN 55022, IEC 61000-4-2, -3, -4 and -6, CE, FCC Class B, UL
1) For UL applications: for use in class 2 circuits according to NEC only
Order guide Designation
Part No. 1)
Single line scanner with beam exit at the front M optics, with M12 connector M optics, with 2m cable
BCL 8 SM 102 BCL 8 SM 552
500 38949 500 38948
N optics, with M12 connector N optics, with 2m cable
BCL 8 SN 102 BCL 8 SN 552
501 05418 501 05420
Single line scanner with lateral beam exit M optics, with M12 connector M optics, with 2m cable
BCL 8 SM 100 BCL 8 SM 550
500 40229 500 40230
N optics, with M12 connector N optics, with 2m cable
BCL 8 SN 100 BCL 8 SN 550
501 05417 501 054191) for USA onlyBCL 8 ... - 090807
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
BCL 8 Reading curves BCL 8 …M … with M optics (medium density), 600 scans/s BCL 8 S M 100 BCL 8 S M 550 0
1020304050607080lateral beam exit
90 100 110 120 130 140 150
70 60 50
Code 2/5 int. Ratio 1:2.5 Class A acc. to ANSI
reading field width in mm
40 30m=0.150 mm (6 mil)20 10m=0.2 mm (8 mil)0m=0.3 mm (12 mil)-10 -20m=0.5 mm (20 mil)-30 -40 -50 -60
BCL 8 S M 102 BCL 8 S M 552
-70 010 203040 506070 80beam exit at the front
90 100 110 120 130 140 150 160 170
distance in mm
BCL 8 …N … with N optics (high density), 500 scans/s BCL 8 SN 100 BCL 8 SN 550 0
1020304050607080lateral beam exit90 100 11070 60 50
Code 2/5 int. Ratio 1:2.5 Class A acc. to ANSI
reading field width in mm
40 30m=0.127 mm (5 mil)20 10m=0.15 mm (6 mil)0m=0.2 mm (8 mil)-10 -20m=0.25 mm (10 mil)-30 -40 -50 -60
BCL 8 SN 102 BCL 8 SN 552
-70 010 203040 506070 80
90 100 110 120 130 140 150 160 170
beam exit at the front
distance in mm
Leuze electronic GmbH + Co. KG info@leuze.de • www.leuze.com
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
BCL 8 ... - 09
Page4of 4
Open in the PDF
The text of page 4, read from a scan by OCR; it may hold reading errors
@& Leuze electronic BCL 8
BCL 8... - 09 0807