Barcode reader BCL 8 with integrated decoder: Technical Description: 7 Commissioning
Pages 29 to 31 of 58, from Barcode reader BCL 8 with integrated decoder: Technical Description
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze BCL-8
Page 29
Leuze electronic 7
Commissioning
Commissioning Attention Laser Radiation! Follow the safety notices in chapter 2.3 on page 6!
7.1
Measures to be performed prior to the initial commissioning © Before commissioning, familiarise yourself with the operation and configuration of the device(s)! © Before connecting the supply voltage, recheck all connections and ensure that they have been properly made.
7.2
Function Test "Power On" test After connecting the operating voltage, the BCL 8 performs an automatic "Power On" function test. Then, the green status LED on the top side of the BCL 8 lights up.
Interface Proper function of the interface can be tested easiest in service operation using the service interface with the "BCLConfig" programming software and a notebook computer.
Using the ’Online’ commands, important device functions can be checked, e.g. proper functioning of the laser.
Problems Should problems occur during device commissioning, refer first to chapter 8.2. Should a problem persist after checking all electrical connections and settings on the devices and host, please contact a Leuze service office near you (see the back page of this operating manual).
Leuze electronic
BCL 8
27
TNT 35/7-24V
Online commands
Page 30
Leuze electronic
Commissioning 7.3
Setting the Parameters You have now commissioned the BCL 8. Usually, you will have to configure it before you can use it. Using the parameter options made available by the BCL 8, you may configure the bar code reader to suit your individual area of application. For instructions regarding the various setting options refer to chapter 9 or to the online help of the BCLConfig program. In order to operate the BCL 8, it is typically sufficient to set code type and code length in accordance with the bar codes that are to be read. However, depending on the application, you will additionally activate the autoReflAct function and configure the switching inputs/ output according to your requirements. The setting of code type and code length is usually accomplished by using the program BCLConfig, see "Installing the BCLConfig software" on page 31. To understand what is happening during the parameter setting, the following chapter 7.3.1 briefly explains the various parameter sets. The setting of the parameter sets then takes place in the operating mode "service", which is described in chapter 7.3.2.
7.3.1
Parameter sets Factory default parameter set This parameter set contains the default settings made ex works for all BCL 8 parameters. It is permanently stored in the ROM of the BCL 8. The parameter set with the default settings is loaded into the memory of the BCL 8 • the first time the device is commissioned after delivery • following the command "Factory Default" in the parameterisation program • if the checksums of the current parameter set are invalid.
Current parameter set In this parameter set, the current settings for all device parameters are stored. When the BCL 8 is in operation, the parameter set is stored in the EEPROM of the BCL 8. The current set can be stored: • by copying a valid parameter set from the host computer to the BCL 8 • by an off-line setup using the configuration software BCLConfig and the subsequent copying into the BCL 8 The current parameter set is loaded into the memory of the BCL 8 • each time the supply voltage is connected • following a software reset The current parameter set is overwritten by the parameter set with the default settings: • by a parameter reset, see page 52 28
BCL 8
Leuze electronic
Page 31
Leuze electronic 7.3.2
Commissioning
Service Operating Mode Setting the required parameters is carried out easiest in the "service" operating mode. The operating mode Service makes the following defined operating parameters available on the RS232 interface, independent from the BCL’s configuration for standard operation: • • • • • • transfer rate 9600 baud no parity 8 data bits 1 stop bit prefix: STX postfix: CR, LF
Service interface active The service interface may be activated as follows: • via a command during power-up (initialisation phase). • via a defined bar code label ("Service", see accompanying leaflet) in front of the reading window during power-up (initialisation phase).
Connection You can connect a PC or terminal to the BCL 8 via the serial interface and configure the BCL 8 through this connection. The connection is made using a crossed RS 232 connection cable that establishes the RxD, TxD and GND connections between PC and BCL 8. If the BCL 8 is connected to a connector unit, you can establish the connection in the same way in front of the connector unit. For the respective connection specifications please refer to the data sheet of the connector unit.
TNT 35/7-24V
Service Operating Mode
3 GND 2 TxD 4 RxD PC
BCL 8
Figure 7.1: Connecting the RS 232 service interface to a PC or terminal
Leuze electronic
BCL 8
29