For the Leuze BCL-8

Page 22

Leuze electronic

Installation

6

Installation

6.1

Storage, Transportation Attention! When transporting, package the device so that it is protected against collision and humidity. Optimal protection is achieved when using the original packaging. Heed the required environmental conditions specified in the technical data.

Unpacking © Check the packaging for any damage. If damage is found, notify the post office or shipping agent as well as the supplier. © Check the delivery contents using your order and the delivery papers: • Delivered quantity • Device type and model as indicated on the nameplate • Laser warning signs • Brief manual The name plates provide information as to what BCL-type your device is. For specific information, please refer to chapter 4.4.1.

Name plate BCL 8

Type designation BCL 8

Figure 6.1: Device name plate BCL 8 © Save the original packaging for later storage or shipping. If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office. © Observe the local regulations regarding disposal and packaging.

Cleaning © Clean the glass window of the BCL 8 with a soft cloth before mounting.Remove all packaging remains, e.g. carton fibres or Styrofoam balls. Attention! Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device. 20

BCL 8

Leuze electronic

Page 23

Leuze electronic 6.2

Installation

Mounting Attention Laser Radiation! Follow the safety notices in chapter 2.3 on page 6!

Accessories The wide variety of mounting systems is available for installation. They may be ordered separately from Leuze electronic. Please select the part number from the separate data sheet (available from the Internet under www.leuze.de).

Mounting the BCL 8 There are three basic types of mounting arrangements for the BCL 8: • using the dovetail and the corresponding mounting accessories • using the fastening threads on the back- and underside of the device (chapter 4.3) • using the two « 4.4mm holes (chapter 4.3)

TNT 35/7-24V

Mounting example BCL 8

Rod mounting with mounting system UMS 8.1-D…

Figure 6.2: Mounting example BCL 8

Installation of connector unit MA 8 You can mount the connector unit MA 8 according to your needs by using the two mounting holes. Subsequently, connect the BCL 8 with the connector unit via the respective cable (see separate data sheet for MA 8).

Leuze electronic

BCL 8

21

Page 24

Leuze electronic

Installation 6.2.1

Device Arrangement Selecting a mounting location In order to select the right mounting location, several factors must be considered: • size, orientation, and position tolerance of the bar codes on the objects to be scanned • the reading field of the BCL 8 in relation to the bar code module width • the resulting minimum and maximum reading distance from the respective reading field (for specific information, please refer to chapter 4.4) Notice! The best reading results are obtained when • the bar code is moved along the reading window rotated by > 10° • the reading distance lies in the middle area of the reading field • you do not use high-gloss labels. Notice! In the case of front beam exit, the beam at the BCL 8 exits almost perpendicular to the reading window. In the case of the side beam exit, it exits with a deviation of 15° from the perpendicular. The bar code label must be rotated by > 10° to avoid a total reflection of the laser beam in the case of shiny labels.

a = azimuth angle b = angle of inclination g = angle of rotation

γ

β

Recommended angle of rotation: g > 10°

α Figure 6.3: Definition of the reading angles BCL 8

Mounting location © When selecting a mounting location, pay attention to • maintaining the required environmental conditions (temperature, humidity) • possible soiling of the reading window due to liquids, abrasion by boxes, or packaging material residues. • lowest possible chance of damage to the scanner by mechanical collision or jammed parts. • possible foreign light influence (no direct sunlight). 22

BCL 8

Leuze electronic

Page 25

Leuze electronic 6.3

Installation

Connection Attention! The bar code reader BCL 8 is completely sealed and cannot be opened. Do not try to open the device under any circumstances, as this voids both Protection Class IP 67 and the warranty. Before connecting the device, be sure that the supply voltage agrees with the value printed on the nameplate. Connection of the device and maintenance work while under voltage must only be carried out by a qualified electrician. The power supply unit for the generation of the supply voltage for the BCL 8 and the respective connector units must have a secure electrical insulation through double insulation and safety transformers according to DIN VDE 0551 (IEC 742). Take care to connect the protective conductor correctly to the housing screen. Error-free operation is only guaranteed when the device is properly earthed. If faults cannot be corrected, the device should be removed from operation and protected against possible use.

6.3.1

Connecting the BCL 8

TNT 35/7-24V

BCL 8 connection assignment plan view connector BCL 8

Figure 6.4: BCL 8 connection assignment

Wiring description Pin 1

+5V DC

Pin 2

RS 232 TxD signal line TxD of the RS232 interface

Pin 3

GND operating voltage 0V DC / reference ground

Pin 4

RS 232 RxD signal line RxD of the RS232 interface

Pin 5

SW IN/OUT switching input or switching output

Table 6.1: Leuze electronic operating voltage 5V DC

Wiring description BCL 8 BCL 8

23

Page 26

Leuze electronic

Installation 6.3.2

Connection of switching input/output The BCL 8 is provided with a switching input or a switching output. You can configure the respective function (input or output) according to your requirements using the supplied BCLConfig software.

Switching input (default) In the standard setting (active low), you can trigger a read process via the combined switching input or output connector SW IN/OUT by connecting SW IN/OUT (pin 5) to GND (pin 3). The 2.2 kW "pull-up" resistor must be connected externally (Connection version 1, figure 6.5). Connection version 1: standard setting (active low) BCL 8 5,4 V DC 4.94,9 ……5.4VDC

1

+ 5 V DC

5

SW_IN/OUT

3

GND input resistance 36 kW

2.2 k

GND

Figure 6.5: Switching input BCL 8 connection version 1 (standard setting) In the setting "inverted" (active high), you can trigger a read process by feeding a voltage of 5VDC (pin 1) to SW IN/OUT (pin 5) (Connection version 2, figure 6.6). Connection version 2: Setting "inverted"(active low) BCL 8

4.94,9 ……5.4VDC 5,4 V DC

1

+ 5 V DC input resistance 36 kW 5

SW_IN/OUT

3

GND

GND

Figure 6.6: Switching input BCL 8 connection version 2 (setting "inverted") 24

BCL 8

Leuze electronic

Page 27

Leuze electronic

Installation

Switching output The switching output connection between SW IN/OUT (pin 5) and GND (pin 3) can be activated in the scanner setup. In the default setting, the switching output SW IN/OUT is switched to GND (pin 3) if a code is recognised. BCL 8 1

4.94,9 ……5.4VDC 5,4 V DC

+ 5 V DC input resistance 36 kW + 5 … 30 V DC max. 20 mA !

RL

5

SW_IN/OUT

3

GND

GND

Figure 6.7: Switching output BCL 8

Attention!

Notice! You can configure the switching input/output according to your needs, using the program BCL Config supplied.

Leuze electronic

BCL 8

25

TNT 35/7-24V

Do not load the BCL 8 switching output with more than 20mA at +5 … 30VDC!

Page 28

Leuze electronic

Installation 6.3.3

Wire lengths The following maximum lengths for wires must be observed: Connection

Interface

BCL 8 - Host

RS 232

< 3m

Switching input/output

< 3m

Supply voltage

< 3m

Table 6.2:

6.4

Max. wire length

Wire lengths

Disassembling, Packing, Disposing Repacking For later reuse, the device is to be packed so that it is protected against shocks and dampness. Optimal protection is achieved when using the original packaging. Notice! Electrical scrap is a special waste product! Observe the locally applicable regulations regarding disposal of the product.

26

BCL 8

Leuze electronic