Page 10

Leuze electronic

Description

3

Description BCL 8 device construction BCL 8 S M 102

BCL 8 S M 100

Through holes

Through holes « 4.4 for fastening

M12 round connectors, turning

« 4.4 for fastening

M12 round connectors, turning

Reading window with beam exit on the side

Reading window with beam exit at the front

2 M4 fastening threads at the rear and bottom side of the device

Figure 3.1: BCL 8 device construction

3.1

The Bar Code Reader BCL 8 The bar code reader BCL 8 is a laser scanner with integrated decoder for all bar codes currently in use, e.g. 2/5 Interleaved, EAN etc., with an extremely small housing. The many possible configurations of the device allow its adaptation to a multitude of reading tasks. Due to the small dimensions of the unit and the wide reading field, the BCL 8 may also be used in highly constrained spaces. Information on technical data and characteristics can be found in chapter 4.

8

BCL 8

Leuze electronic

Page 11

Leuze electronic 3.2

Description

Standalone operation The bar code reader BCL 8 is operated as a "stand-alone" device. It is equipped with a fivecore cable with open ends or a 5-pin M12 round connector for the electrical connection of the supply voltage, the interface and the switching input.

With connector unit MA 8 The connector unit MA 8 simplifies the electrical installation of the bar code reader in standalone operation.

TNT 35/7-24V

Separate data sheets are available that contain details about the connector units.

Leuze electronic

BCL 8

9

Page 12

Leuze electronic

Specifications

4

Specifications

4.1

General Specifications BCL 8 Optical Data Light source Scanning rate Resolution Beam deflection Beam exit Reading distance Reading field opening Laser safety class Code types

Software features

Electrical data Interface type Service interface

Baud rate Data formats

Protocols Ports

LEDs Operating voltage Current consumption Table 4.1:

10

Laser diode 650nm 600 scans/s m = 0.150mm … 0.5mm / 6mil … 20mil by means of rotating polygon mirror wheel at front, alternatively on the side with deflection mirror (105°) see reading fields see reading fields class 2 acc. to EN 60825-1 class II acc. to 21 CFR 1040.10 2/5 Interleaved, Code 39, Code 128, EAN 128, EAN/ UPC, EAN Addendum, Codabar, Pharma Code, Code 93 selectable output format, autoConfig, autoReflAct, reference code comparison, multiple read, real time decoding, adjustment mode, control of switching input or switching output, etc. RS 232 RS 232 with fixed data format 9600Bd, 8 data bits, no parity, 1 stop bit STX "Data", CR, LF 4800 … 57600Bd data bits: 7, 8 parity: None, Even, Odd stop bits: 1, 2 framing protocol with/without handshake software handshake X ON / X OFF 1 switching input 5VDC or 1 switching output 5 … 30V, 20mA 1 device status 1 read status 4.9 … 5.4VDC, low voltage acc. to IEC 742 max. 250mA (2W power supply unit recommended)

Specifications

BCL 8

Leuze electronic

Page 13

Leuze electronic Mechanical data Protection class Connection type Weight Dimensions (WxHxD) Housing

Specifications

IP 67 M12 connector, 5-pin, turning or fixed cable, 2m long, 5 x 0.25mm2 70g beam exit at front: 48 x 40.3 x 15mm beam exit on the side: 48x58x17.4mm metal (diecast zinc)

Environmental data Ambient temp. (operation/storage) 0°C … +40°C/-20°C … +60°C Air humidity max. 90% rel. humidity, non-condensing Vibration IEC 60068-2-6, test FC Shock IEC 60068-2-27, test Ea Electromagnetic compatibility EN 61326-1, IEC 6100-4-2, -3, -4 and -6, Certificates CE, EN 55022, FCC Class B Table 4.1:

4.2

Specifications

LED indicators Two 3-colour LEDs at the top of the case show the device and reading status:

Status LED

Decode LED Table 4.2:

Leuze electronic

Colour

Meaning

Green flashing initialisation phase

Green continuous ready for operation

Red flashing (200ms)

warning

Red continuous error, no function

Orange flashing (200ms)

service operation

Green (200ms on)

reading successful

Red (200ms off)

no reading result

Orange continuous reading gate active

TNT 35/7-24V

LED

LED indicators

BCL 8

11

Page 14

Leuze electronic

Specifications 4.3

Dimensioned and Connection Drawings BCL 8 S M …0 with side beam exit

Thread depth: 3mm

Thread depth: 3mm

B1 B2 A B C D

Turning connector, 90° Indicator LEDs (B1: status LED, B2: decode LED) Laser beam Optical axis

Figure 4.1: Dimensioned drawing BCL 8 S M …0 with lateral beam exit 12

BCL 8

Leuze electronic

Page 15

Leuze electronic

Specifications

BCL 8 S M …2 with front beam exit Thread depth: 3mm

TNT 35/7-24V

Thread depth: 3mm

B1 B2 A B C D

Turning connector, 90° Indicator LEDs (B1: status LED, B2: decode LED) Laser beam Optical axis

Figure 4.2: Dimensioned drawing BCL 8 S M …2 with front beam exit

Leuze electronic

BCL 8

13

Page 16

Leuze electronic

Specifications 4.4

Optical Data Notice! Please note that the size of the bar code module influences the maximum reading distance and the width of the reading field. Therefore, when selecting a mounting location and/or the bar code label, take into account the different reading characteristics of the scanner with various bar code modules. The BCL 8 is available in various models for various reading tasks and connection requirements (see chapter 4.4.1 "Type overview").

4.4.1

Type overview

Model

Range

Connection Scanner type Module/ beam exit resolution [mm]

BCL 8 S M 100 BCL 8 S M 102 BCL 8 S M 550

M12 round connector up to 160mm

0.15 … 0.5 fixed cable (2m)

BCL 8 S M 552 Table 4.3:

14

Part No.

Single line/ lateral

500 40229

Single line/ front

500 38949

Single line/ lateral

500 40230

Single line/ front

500 38948

Type overview

BCL 8

Leuze electronic

Page 17

Leuze electronic 4.4.2

Specifications

Reading Fields Notice! Please notice that the real reading fields are also influenced by factors such as labelling material, printing quality, scanning angle, printing contrast etc., and may thus deviate from the reading fields specified here. The origin of the reading distance always refers to the front edge of the housing of the beam window.

Reading field BCL 8 with front beam exit 70 m=0.150 mm (6 mil)

60 m=0.2 mm (8 mil)

50

Reading field width [mm]

40 m=0.3 mm (12 mil)

30 m=0.5 mm (20 mil)

20 10 0 -10 -20 -30 -40 -50

-70 0

10 20

30

40 50

60

70 80

TNT 35/7-24V

Code 2/5 int. Ratio 1:2.5 Class A acc. to ANSI

-60

90 100 110 120 130 140 150 160 170

Reading distance [mm]

Figure 4.3: Reading field BCL 8 S M …2 with front beam exit

Leuze electronic

BCL 8

15

Page 18

Leuze electronic

Specifications Reading field BCL 8 with side beam exit 70 m=0.150 mm (6 mil)

60 m=0.2 mm (8 mil)

50

Reading field width [mm]

40 m=0.3 mm (12 mil)

30 m=0.5 mm (20 mil)

20 10 0 -10 -20 -30 -40 -50

Code 2/5 int. Ratio 1:2.5 Class A acc. to ANSI

-60 -70 0

10 20

30

40 50

60

70 80

90 100 110 120 130 140 150 160 170

Reading distance [mm]

Figure 4.4: Reading field BCL 8 S M …0 with side beam exit

16

BCL 8

Leuze electronic