The text of a manual · part 3 of 10
Barcode reader BCL 8 with integrated decoder: Technical Description, pages 10 to 18
Pages 10 to 18 of 58: 3 Description; 4 Specifications
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze BCL-8
Page 10
Leuze electronic
Description
3
Description BCL 8 device construction BCL 8 S M 102
BCL 8 S M 100
Through holes
Through holes « 4.4 for fastening
M12 round connectors, turning
« 4.4 for fastening
M12 round connectors, turning
Reading window with beam exit on the side
Reading window with beam exit at the front
2 M4 fastening threads at the rear and bottom side of the device
Figure 3.1: BCL 8 device construction
3.1
The Bar Code Reader BCL 8 The bar code reader BCL 8 is a laser scanner with integrated decoder for all bar codes currently in use, e.g. 2/5 Interleaved, EAN etc., with an extremely small housing. The many possible configurations of the device allow its adaptation to a multitude of reading tasks. Due to the small dimensions of the unit and the wide reading field, the BCL 8 may also be used in highly constrained spaces. Information on technical data and characteristics can be found in chapter 4.
8
BCL 8
Leuze electronic
Page 11
Leuze electronic 3.2
Description
Standalone operation The bar code reader BCL 8 is operated as a "stand-alone" device. It is equipped with a fivecore cable with open ends or a 5-pin M12 round connector for the electrical connection of the supply voltage, the interface and the switching input.
With connector unit MA 8 The connector unit MA 8 simplifies the electrical installation of the bar code reader in standalone operation.
TNT 35/7-24V
Separate data sheets are available that contain details about the connector units.
Leuze electronic
BCL 8
9
Page 12
Leuze electronic
Specifications
4
Specifications
4.1
General Specifications BCL 8 Optical Data Light source Scanning rate Resolution Beam deflection Beam exit Reading distance Reading field opening Laser safety class Code types
Software features
Electrical data Interface type Service interface
Baud rate Data formats
Protocols Ports
LEDs Operating voltage Current consumption Table 4.1:
10
Laser diode 650nm 600 scans/s m = 0.150mm … 0.5mm / 6mil … 20mil by means of rotating polygon mirror wheel at front, alternatively on the side with deflection mirror (105°) see reading fields see reading fields class 2 acc. to EN 60825-1 class II acc. to 21 CFR 1040.10 2/5 Interleaved, Code 39, Code 128, EAN 128, EAN/ UPC, EAN Addendum, Codabar, Pharma Code, Code 93 selectable output format, autoConfig, autoReflAct, reference code comparison, multiple read, real time decoding, adjustment mode, control of switching input or switching output, etc. RS 232 RS 232 with fixed data format 9600Bd, 8 data bits, no parity, 1 stop bit STX "Data", CR, LF 4800 … 57600Bd data bits: 7, 8 parity: None, Even, Odd stop bits: 1, 2 framing protocol with/without handshake software handshake X ON / X OFF 1 switching input 5VDC or 1 switching output 5 … 30V, 20mA 1 device status 1 read status 4.9 … 5.4VDC, low voltage acc. to IEC 742 max. 250mA (2W power supply unit recommended)
Specifications
BCL 8
Leuze electronic
Page 13
Leuze electronic Mechanical data Protection class Connection type Weight Dimensions (WxHxD) Housing
Specifications
IP 67 M12 connector, 5-pin, turning or fixed cable, 2m long, 5 x 0.25mm2 70g beam exit at front: 48 x 40.3 x 15mm beam exit on the side: 48x58x17.4mm metal (diecast zinc)
Environmental data Ambient temp. (operation/storage) 0°C … +40°C/-20°C … +60°C Air humidity max. 90% rel. humidity, non-condensing Vibration IEC 60068-2-6, test FC Shock IEC 60068-2-27, test Ea Electromagnetic compatibility EN 61326-1, IEC 6100-4-2, -3, -4 and -6, Certificates CE, EN 55022, FCC Class B Table 4.1:
4.2
Specifications
LED indicators Two 3-colour LEDs at the top of the case show the device and reading status:
Status LED
Decode LED Table 4.2:
Leuze electronic
Colour
Meaning
Green flashing initialisation phase
Green continuous ready for operation
Red flashing (200ms)
warning
Red continuous error, no function
Orange flashing (200ms)
service operation
Green (200ms on)
reading successful
Red (200ms off)
no reading result
Orange continuous reading gate active
TNT 35/7-24V
LED
LED indicators
BCL 8
11
Page 14
Leuze electronic
Specifications 4.3
Dimensioned and Connection Drawings BCL 8 S M …0 with side beam exit
Thread depth: 3mm
Thread depth: 3mm
B1 B2 A B C D
Turning connector, 90° Indicator LEDs (B1: status LED, B2: decode LED) Laser beam Optical axis
Figure 4.1: Dimensioned drawing BCL 8 S M …0 with lateral beam exit 12
BCL 8
Leuze electronic
Page 15
Leuze electronic
Specifications
BCL 8 S M …2 with front beam exit Thread depth: 3mm
TNT 35/7-24V
Thread depth: 3mm
B1 B2 A B C D
Turning connector, 90° Indicator LEDs (B1: status LED, B2: decode LED) Laser beam Optical axis
Figure 4.2: Dimensioned drawing BCL 8 S M …2 with front beam exit
Leuze electronic
BCL 8
13
Page 16
Leuze electronic
Specifications 4.4
Optical Data Notice! Please note that the size of the bar code module influences the maximum reading distance and the width of the reading field. Therefore, when selecting a mounting location and/or the bar code label, take into account the different reading characteristics of the scanner with various bar code modules. The BCL 8 is available in various models for various reading tasks and connection requirements (see chapter 4.4.1 "Type overview").
4.4.1
Type overview
Model
Range
Connection Scanner type Module/ beam exit resolution [mm]
BCL 8 S M 100 BCL 8 S M 102 BCL 8 S M 550
M12 round connector up to 160mm
0.15 … 0.5 fixed cable (2m)
BCL 8 S M 552 Table 4.3:
14
Part No.
Single line/ lateral
500 40229
Single line/ front
500 38949
Single line/ lateral
500 40230
Single line/ front
500 38948
Type overview
BCL 8
Leuze electronic
Page 17
Leuze electronic 4.4.2
Specifications
Reading Fields Notice! Please notice that the real reading fields are also influenced by factors such as labelling material, printing quality, scanning angle, printing contrast etc., and may thus deviate from the reading fields specified here. The origin of the reading distance always refers to the front edge of the housing of the beam window.
Reading field BCL 8 with front beam exit 70 m=0.150 mm (6 mil)
60 m=0.2 mm (8 mil)
50
Reading field width [mm]
40 m=0.3 mm (12 mil)
30 m=0.5 mm (20 mil)
20 10 0 -10 -20 -30 -40 -50
-70 0
10 20
30
40 50
60
70 80
TNT 35/7-24V
Code 2/5 int. Ratio 1:2.5 Class A acc. to ANSI
-60
90 100 110 120 130 140 150 160 170
Reading distance [mm]
Figure 4.3: Reading field BCL 8 S M …2 with front beam exit
Leuze electronic
BCL 8
15
Page 18
Leuze electronic
Specifications Reading field BCL 8 with side beam exit 70 m=0.150 mm (6 mil)
60 m=0.2 mm (8 mil)
50
Reading field width [mm]
40 m=0.3 mm (12 mil)
30 m=0.5 mm (20 mil)
20 10 0 -10 -20 -30 -40 -50
Code 2/5 int. Ratio 1:2.5 Class A acc. to ANSI
-60 -70 0
10 20
30
40 50
60
70 80
90 100 110 120 130 140 150 160 170
Reading distance [mm]
Figure 4.4: Reading field BCL 8 S M …0 with side beam exit
16
BCL 8
Leuze electronic