For the Leuze BCL-8

Page 35

Leuze electronic 10

Important Parameters

10.1

Code menu

Important Parameters

Code table

Here, the codes which are to be decoded are set. We recommend enabling only the code types which are to actually be read with the corresponding element numbers.

Element number

In the field Element number, up to 3 element entries may be entered. An area is represented by a dashed line: e.g. 4-40 digits. With 2 or 3 different element entries by a comma: e.g: 8,13 digits The combination is also possible, but the range must be specified first: e.g.: 4-10,20 digits

Notice! If the code EAN128 is to be read, 3 additional characters are to be set for the code identifier. Properties

Behind the "Properties" button, to the right of the respective code, the code-specific settings, such as the check digit, can be selected.

Number of bar Here, the number of the bar codes to be decoded within a read cycle (one codes reading gate) is set.

Leuze electronic

BCL 8

33

TNT 35/7-24V

Figure 10.1: Default setting of the code menu with the CONFIG 3 configuration software.

Page 36

Leuze electronic

Important Parameters 10.2

Properties of the Code menu

Figure 10.2: Standard setting of the properties of the code menu Quiet zone size

Quiet zone: the area to the left and right of the bar code Module: width of the narrowest line in the bar code According to the code specifications, each bar code must have a quiet zone which is 10x as wide as the module of the bar code. Ex: for a code having a module of 0.5mm, 5mm blank space must be present at both the left and right of the code. By default, the scanner checks the a quiet zone which is 7 times greater than the module. This means that 7x or greater is o.k.

Reading Security Specifies how often a code must be decoded before the result is valid (Equal Scans) and output. This value should be increased for inspection and test purposes only. No time correlation

If this parameter is set, a gap between two identical labels is ignored and they are treated as a single label.

No position correlation

If this parameter is set, then the position of a bar code label in the reading beam is not taken into account. Identical labels are treated as a single label

Notice! In general, the remaining parameters must not be changed. In the worst case, this could corrupt the reading result!

34

BCL 8

Leuze electronic

Page 37

Leuze electronic 10.3

Important Parameters

Output menu

Figure 10.3: Output menu Select from the options listed below. The output header is sent in a separate message before the read result.

Label header

The Label header is set directly before the code data.

Label footer

The label footer is appended directly to the code data.

Message mode

Selects whether the bar codes read are sent in concatenation or separately as individual strings.

TNT 35/7-24V

Output header

Notice! -The structure of this message string is depicted symbolically in the preview window. No read string

This character is set for each unrecognised bar code. Multiple characters (=string) may be entered here. Up to 20 characters are possible.

Properties

Set the desired formatting modes and formatting characters as necessary.

Leuze electronic

BCL 8

35

Page 38

Leuze electronic

Important Parameters 10.4

Control

Figure 10.4: Control menu default settings

Activation Sensor 1 function see menu "switching input" Autostart after decoding

In this mode, the scanner reads via an internal trigger signal with maximum performance. Attention: Up to 100 codes per second may be transmitted.

Command character

The standard online character for the trigger start is the ´+´ character. This character can be changed only via the tree structure.

Decode delay time This point is usually used only for test purposes. After the time set here has passed, the scanner automatically reactivates itself following a reading gate end.

36

BCL 8

Leuze electronic

Page 39

Leuze electronic

Important Parameters

Deactivation Sensor 1 function see menu "switching input" Reading security reached (equal scans)

If this item is activated, the read result is output immediately after the bar code is decoded. If the item is deactivated, the read result is sent only after the trigger signal is returned (=end of reading gate).

Command character

The standard online character for the trigger end is the ´-´ character. This character can be changed only via the tree structure.

Time

For test purposes. If the scanner is activated, the reading gate is automatically closed by the scanner after this preset time has elapsed.

Scans without info Following a successful read, the scanner waits for this number of scans (sequential scans with no read result) before it automatically deactivates itself.

Communication

TNT 35/7-24V

10.5

Figure 10.5: Standard setting of the communication menu Select the desired baud rate, the stop bits, the data bits, the parity, and various transmission modes here.

Leuze electronic

BCL 8

37

Page 40

Leuze electronic

Important Parameters 10.5.1

Communication properties

Figure 10.6: Standard setting of the property menu Here, you can change the addresses settings and the protocol for sending and receiving.

38

BCL 8

Leuze electronic

Page 41

Leuze electronic 10.6

Important Parameters

Reference code

Figure 10.7: Reference code menu A reference code is bar code information which is stored in the memory of the scanner.

One way to store the reference code is to enter it manually in this menu. You can find further options of the reference code teach-in in the chapter on online commands. Type

Select the code type.

Info

Contents of the reference code

Compare mode

Select here how the internally stored reference code is to be compared with the decoded result. -> For additional comparison possibilities, please select the "Properties" menu

Leuze electronic

BCL 8

39

TNT 35/7-24V

This reference code can be compared with the current decoded bar code in various modes and, thus, set appropriately for the switching output. To do this, the switching output must still be set to "By comparison of reference code X" in the "Switch" menu.

Page 42

Leuze electronic

Important Parameters 10.7

Sensor

Figure 10.8: Standard setting of the switching input menu Invert

Here, the input level can be inverted.

Enable

Switching input enabled or disabled.

Debounce time

This time period must lapse until the trigger signal is regarded as valid.

Delay on time

The trigger signal is passed on delayed by the specified time period.

Pulse duration

If the value is higher than "0": duration of the activation, regardless of how long the trigger signal has been present.

Delay off time

After the end of the trigger signal, the pulse is extended internally by this time period.

Notice! If the switch-off delay is activated, the parameter "pulse duration" should be "0". Function

Event that is started when the switching input is activated.

Attention! Depending on the connection configuration, the BCL 8 either has a switching input or a switching output.

40

BCL 8

Leuze electronic

Page 43

Leuze electronic 10.8

Important Parameters

Laser

Figure 10.9: Laser menu Start position and Here, you can narrow down the reading field width of the laser beam. stop position

• Standard reading operation This is the standard mode without the reflector polling function • Slow reflector polling with automatic reading gate control In this mode, the decoding of the label is automatically started after the scanning beam to the reflector has been interrupted. The decoding is terminated no later than when the scanning beam to the reflector is cleared. This mode is intended for applications with slow transport speeds of about < 0.5m/s. • Fast reflector polling without automatic reading gate control In this mode, the decoding does not start automatically. Starting must be activated via a controller or via a switching input. This mode is intended for scanners with fast transport speeds of about > 0.5m/s. This mode is also of interest if a programmable logic controller wants to know whether the scanning beam to the reflector is currently interrupted or not. If this is the case, the PLC can start the decoding by sending the + command. The PLC detects the change by receiving the characters "reflector discovered" or "reflector not discovered". • Fast reflector polling with automatic reading gate control As mode 2 for fast transport speeds of about > 0.5m/sec • Slow reflector polling without automatic reading gate control As mode 3, but for slower transport speeds of about < 0.5m/sec

Reflector polling Reflector polling, also called autoReflAct, is an operating mode in which no external sensor is required. The activation and deactivation of the scanner is carried out via the reflector supplied. It must be installed within the scan range of the BCL 8. For easy alignment in the autoReflAct mode, please select the menu "Wizard" (currently under implementation). In the top left corner, below the terminal icon, a small symbol "AutoReflAct Wizard" appears.

Leuze electronic

BCL 8

41

TNT 35/7-24V

Mode

Page 44

Leuze electronic

Important Parameters

If you click on this symbol, the wizard tries to establish a connection to the BCL 8 connected. If this is successful, please select one of the four reflector polling modes under "mode" in the menu that appears. A screen like the following appears:

Figure 10.10:AutoReflAct Wizard When you activate the "search" icon, the BCL 8 scans its reading range and tries to detect a reflector. For this, the reflector must be positioned in the reading range of the scanner. After a reflector has been detected, it passes on the start position of the reflector in its reading range. By clicking "OK", the values are stored in the scanner and in BCLConfig. The scanner is now ready for the AutoReflAct operating mode. Attention! If reflecting objects other than the reflector are in the reading window of the scanner, the application must be checked carefully, as these reflecting objects may cause an incorrect triggering at the scanner! The "fast reflector polling ..." modes are more suitable for applications with reflecting objects than the "slow reflector polling ..." modes

42

BCL 8

Leuze electronic

Page 45

Leuze electronic 10.9

Important Parameters

Switching output

Figure 10.11:Standard setting of the switching output menu Select the desired event which is to initiate the switching of the switching output here. Multiple events can also be simultaneously activated.

Deactivation

This implements the event that leads to the switching output being reset. (in case that the set pulse duration has not expired.) Multiple events can also be simultaneously activated.

Invert

Level inverted

Pulse duration

Duration of the switching output impulse.

TNT 35/7-24V

Activation

Attention! Depending on the connection configuration, the BCL 8 either has a switching input or a switching output.

Leuze electronic

BCL 8

43