What is in it
The technical description for the Leuze BCL 21 and BCL 22, small stationary high-speed laser bar code readers with integrated decoders, and the MA 2 / MA 4 connector units used to wire and network the BCL 21. It covers safety, networking with multiNet plus over RS 485, specifications and reading fields for the N, M and F optics, accessories, mounting and wiring, commissioning, error handling, the BCLConfig software, the important parameters, online commands and maintenance.
Its parts
- General Information
- Safety Notices
- Description
- Specifications
- Accessories / Order Designation
- Installation
- Commissioning
- Operation
- Communicating with the Device
- Important Parameters
- Online commands
- Maintenance
From the manual
Key facts from this manual
Each line names its page in the PDF.
The Leuze electronic technical description (GB 02-06/06 50082282) for the BCL 21/22 bar code reader with integrated decoder and the MA 2 / MA 4 connector units. The BCL 21 is the RS 485 version for networks through an MA 2/MA 4 unit and the BCL 22 the RS 232 stand-alone version. It gives specifications, accessories with part numbers, wiring, commissioning, service mode and error handling.
- Device
- High-speed laser bar code scanner with integrated decoder p. 11
- Host interface
- BCL 21: RS 485; BCL 22: RS 232; both with an additional RS 232 service interface p. 14
- Supply
- 10 to 30VDC, 3.2W p. 14
- Switching I/O
- BCL 21: one switching input and output; BCL 22: two each; a 12 to 30VDC input triggers a read p. 14, 37
- Connection
- 15-pin Sub-D cable; BCL 21: alternately flat connectors to the MA 2/MA 4 connector unit p. 11, 36, 38
- Scan rate
- 1000 scans/s version M; 800 scans/s versions N and F p. 14
- Networking
- BCL 21: up to 30 scanners via MA 2 units and an MA 30/31 multiNet plus master on two-wire RS 485, up to 1200 m p. 12, 13
- Connector units
- MA 2 (50031256), MA 4 with parameter memory (50031537), MA 4D with display (50031536) p. 24, 28
- Service interface
- RS 232, 9600 baud, 8 data bits, no parity, 1 stop bit, STX prefix, CR LF postfix; no RTS/CTS handshake p. 52
- Software
- BCL-Config programming software, part no. 50031298, free download p. 24
- Mounting
- BT 20 (50060503) and BT 21 (50037473) for rod mounting (d = 12 mm) or sheet metal clamp (1.5 to 3mm); two M3 threads, 4mm deep p. 11, 24, 32
- Size and weight
- 82mm x 68mm x 28mm; 180g, 260g with cable; ABS housing, IP 65 p. 14
- Laser
- Red 650nm laser diode, rotating polygon mirror wheel p. 14
- Bar codes
- 2/5 Interleaved, Code 39, Code 93, Code 128, EAN 128, EAN/UPC, EAN Adendum, Codabar, Pharma Code p. 14
What this manual walks you through
- Networking BCL 21 readers with multiNet plus p. 12, 13
- Reading the PWR, ERR and DEC LED states p. 15
- Choosing accessories and connector units by part number p. 24, 25, 26, 27, 28, 29, 30, 31
- Wiring the BCL 21/22 stand-alone through the 15-pin Sub-D connector p. 36, 37
- Wiring the BCL 21 to an MA 2 or MA 4/MA 4D connector unit p. 38, 39, 40, 41, 42, 43
- Setting the device address with the rotary switch p. 49
- Power On function test and resets p. 50
- Parameter sets and the service operating mode p. 51, 52
- Handling warnings and serious errors p. 53
Good to know
- Never open the reader: there is a risk of laser radiation and no user-serviceable parts inside. p. 36
- Wire the protective conductor PE through in the connector unit to avoid electromagnetic interference. p. 40
- On an MA 2, switching input 2 and switching output 2 work only with a BCL 22. p. 40
- Device address 31 is used to reset the parameters. p. 49
- If a hardware problem is present, the reader will not reinitialise. p. 53
Questions this manual answers
What address should a Leuze BCL 21 with MA 2 have?
0 when it is not in a network; 1 to 30 when several units share a multiNet plus network, each with a different address. p. 49
What are the BCL 21/22 service interface settings?
9600 baud, no parity, 8 data bits, 1 stop bit, with STX prefix and CR, LF postfix, over a crossed RS 232 cable. p. 52
How many BCL 21 scanners can be networked?
Up to 30, each through an MA 2 connector unit, with an MA 30/31 bus master. p. 12
What software configures the Leuze BCL 21/22?
The BCL-Config programming software, part no. 50031298, a free download from www.leuze.de. p. 24
What does the ERR LED on the BCL 22 mean?
It shows errors. Warnings are temporary; after a serious error, re-initialise the reader. p. 53
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 12 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- BCL 21/22 Bar Code Reader with Integrated Decoder and Connector Unit MA 2 / MA 41-6
- Pages 7 to 107-10
- 3 Description11-13
- 4 Specifications14-23
- 5 Accessories / Order Designation24-32
- 6 Installation, pages 33 to 4033-40
- 6 Installation, pages 41 to 4841-48
- 7 Commissioning49-52
- Pages 53 to 5553-55
- 10 Important Parameters56-64
- 11 Online commands65-76
- Pages 77 to 8477-84