Page 1 of BCL 21/22 Bar Code Reader with Integrated Decoder and Connector Unit MA 2 / MA 4... Technical Description

Manual · Leuze

BCL 21/22 Bar Code Reader with Integrated Decoder and Connector Unit MA 2 / MA 4... Technical Description

Manual84 pagesPDF 2.1 MB

Technical description of the Leuze BCL 21 and BCL 22 fixed-mount laser bar code readers and MA 2 / MA 4 connector units.

Download the PDF2.1 MB

Covers · 2 models

The models it covers

Summary

What is in it

The technical description for the Leuze BCL 21 and BCL 22, small stationary high-speed laser bar code readers with integrated decoders, and the MA 2 / MA 4 connector units used to wire and network the BCL 21. It covers safety, networking with multiNet plus over RS 485, specifications and reading fields for the N, M and F optics, accessories, mounting and wiring, commissioning, error handling, the BCLConfig software, the important parameters, online commands and maintenance.

Its parts

  1. General Information
  2. Safety Notices
  3. Description
  4. Specifications
  5. Accessories / Order Designation
  6. Installation
  7. Commissioning
  8. Operation
  9. Communicating with the Device
  10. Important Parameters
  11. Online commands
  12. Maintenance

From the manual

Key facts from this manual

Each line names its page in the PDF.

The Leuze electronic technical description (GB 02-06/06 50082282) for the BCL 21/22 bar code reader with integrated decoder and the MA 2 / MA 4 connector units. The BCL 21 is the RS 485 version for networks through an MA 2/MA 4 unit and the BCL 22 the RS 232 stand-alone version. It gives specifications, accessories with part numbers, wiring, commissioning, service mode and error handling.

Read for this summary: pages 1, 11 to 15, 24 to 32, 36 to 43 and 49 to 53 of 84.

Device
High-speed laser bar code scanner with integrated decoder p. 11
Host interface
BCL 21: RS 485; BCL 22: RS 232; both with an additional RS 232 service interface p. 14
Supply
10 to 30VDC, 3.2W p. 14
Switching I/O
BCL 21: one switching input and output; BCL 22: two each; a 12 to 30VDC input triggers a read p. 14, 37
Connection
15-pin Sub-D cable; BCL 21: alternately flat connectors to the MA 2/MA 4 connector unit p. 11, 36, 38
Scan rate
1000 scans/s version M; 800 scans/s versions N and F p. 14
Networking
BCL 21: up to 30 scanners via MA 2 units and an MA 30/31 multiNet plus master on two-wire RS 485, up to 1200 m p. 12, 13
Connector units
MA 2 (50031256), MA 4 with parameter memory (50031537), MA 4D with display (50031536) p. 24, 28
Service interface
RS 232, 9600 baud, 8 data bits, no parity, 1 stop bit, STX prefix, CR LF postfix; no RTS/CTS handshake p. 52
Software
BCL-Config programming software, part no. 50031298, free download p. 24
Mounting
BT 20 (50060503) and BT 21 (50037473) for rod mounting (d = 12 mm) or sheet metal clamp (1.5 to 3mm); two M3 threads, 4mm deep p. 11, 24, 32
Size and weight
82mm x 68mm x 28mm; 180g, 260g with cable; ABS housing, IP 65 p. 14
Laser
Red 650nm laser diode, rotating polygon mirror wheel p. 14
Bar codes
2/5 Interleaved, Code 39, Code 93, Code 128, EAN 128, EAN/UPC, EAN Adendum, Codabar, Pharma Code p. 14

What this manual walks you through

  • Networking BCL 21 readers with multiNet plus p. 12, 13
  • Reading the PWR, ERR and DEC LED states p. 15
  • Choosing accessories and connector units by part number p. 24, 25, 26, 27, 28, 29, 30, 31
  • Wiring the BCL 21/22 stand-alone through the 15-pin Sub-D connector p. 36, 37
  • Wiring the BCL 21 to an MA 2 or MA 4/MA 4D connector unit p. 38, 39, 40, 41, 42, 43
  • Setting the device address with the rotary switch p. 49
  • Power On function test and resets p. 50
  • Parameter sets and the service operating mode p. 51, 52
  • Handling warnings and serious errors p. 53

Good to know

  • Never open the reader: there is a risk of laser radiation and no user-serviceable parts inside. p. 36
  • Wire the protective conductor PE through in the connector unit to avoid electromagnetic interference. p. 40
  • On an MA 2, switching input 2 and switching output 2 work only with a BCL 22. p. 40
  • Device address 31 is used to reset the parameters. p. 49
  • If a hardware problem is present, the reader will not reinitialise. p. 53

Questions this manual answers

What address should a Leuze BCL 21 with MA 2 have?

0 when it is not in a network; 1 to 30 when several units share a multiNet plus network, each with a different address. p. 49

What are the BCL 21/22 service interface settings?

9600 baud, no parity, 8 data bits, 1 stop bit, with STX prefix and CR, LF postfix, over a crossed RS 232 cable. p. 52

How many BCL 21 scanners can be networked?

Up to 30, each through an MA 2 connector unit, with an MA 30/31 bus master. p. 12

What software configures the Leuze BCL 21/22?

The BCL-Config programming software, part no. 50031298, a free download from www.leuze.de. p. 24

What does the ERR LED on the BCL 22 mean?

It shows errors. Warnings are temporary; after a serious error, re-initialise the reader. p. 53

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1 General Information7
    1. 1.1 Explanation of Symbols7
    2. 1.2 Declaration of Conformity7
  2. 2 Safety Notices8
    1. 2.1 Safety Standards8
    2. 2.2 Intended Use8
    3. 2.3 Working Safely9
  3. 3 Description11
    1. BCL 21/22 device construction11
    2. 3.1 The Bar Code Readers BCL 21/2211
  4. 4 Specifications14
    1. 4.1 General Specifications BCL 21/2214
    2. 4.2 LED indicators15
    3. 4.3 Dimensioned and Connection Drawings16
    4. 4.4 Optical Data17
  5. 5 Accessories / Order Designation24
    1. 5.1 Accessories24
  6. 6 Installation33
    1. 6.1 Storage, Transportation33
    2. 6.2 Mounting34
    3. 6.3 Connection36
    4. 6.4 Disassembling, Packing, Disposing48
  7. 7 Commissioning49
    1. 7.1 Measures to be performed prior to the initial commissioning49
    2. 7.2 Function Test50
    3. 7.3 Setting the Parameters51
  8. 8 Operation53
    1. 8.1 Display Elements53
    2. 8.2 Error Handling53
  9. 9 Communicating with the Device54
    1. 9.1 Installing the "BCLConfig"-software54
  10. 10 Important Parameters56
    1. 10.1 Code menu56
    2. 10.2 Output menu58
    3. 10.3 Control59
    4. 10.4 Communication60
    5. 10.5 Reference code62
    6. 10.6 Switching input63
    7. 10.7 Switching output64
  11. 11 Online commands65
8 more lines, from page 65 on
  1. 11.1 Overview of Commands and Parameters65
  2. 12 Maintenance77
    1. 12.1 General Maintenance Information77
    2. 12.2 Repairs, Servicing77
  3. 13 Appendix78
    1. 13.1 ASCII Table78
    2. 13.2 Example Bar Code Label Types82
    3. 13.3 Declaration of Conformity BCL 21/2284

From the PDF’s own bookmarks.

The whole text · 12 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. BCL 21/22 Bar Code Reader with Integrated Decoder and Connector Unit MA 2 / MA 41-6
  2. Pages 7 to 107-10
  3. 3 Description11-13
  4. 4 Specifications14-23
  5. 5 Accessories / Order Designation24-32
  6. 6 Installation, pages 33 to 4033-40
  7. 6 Installation, pages 41 to 4841-48
  8. 7 Commissioning49-52
  9. Pages 53 to 5553-55
  10. 10 Important Parameters56-64
  11. 11 Online commands65-76
  12. Pages 77 to 8477-84

The file

Revision and size

RevisionGB 02-06/06 50082282
PublisherLeuze electronic GmbH + Co. KG
Pages84
PDF2.1 MB
TextText from the PDF itself.

The first pages · 3 of 84

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 84
Page 2
Page 2of 84
Page 3
Page 3of 84

More documents · 1

For the same models