Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Leuze BCL-21 and BCL-22 Spec Sheet

Spec sheet · Leuze

Leuze BCL-21 and BCL-22 Spec Sheet

Spec sheet4 pagesPDF 337 KB

All 4 pages are below, each with its text.

Download the PDF337 KB

Covers · 2 models

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A four-page Leuze electronic data sheet for the BCL 21/22 barcode reader, a compact laser scanner made in raster and single-line versions. The BCL 21 has an RS 485 host interface and the BCL 22 an RS 232 one. It gives the optical, electrical and mechanical data, the connector pinouts, reading curves for the N, M and F optics, and the type key for ordering.

Device
Laser barcode reader, raster scanner or single-line scanner versions p. 1
Host interface
BCL 21: RS 485; BCL 22: RS 232; 110 to 115200Bd p. 2
Switching I/O
BCL 21: 1 switching output, 1 switching input; BCL 22: 2 switching outputs, 2 switching inputs p. 2
Supply
10 to 30 V DC, max. 3.2W p. 1, 2
Optics and scan rate
N-Optics 0.15 to 0.5mm at 800 scans/s; M-Optics 0.2 to 0.8mm at 1000 scans/s; F-Optics 0.5 to 1.0mm at 800 scans/s p. 2
Operating range
N High Density up to 95mm; M Medium Density up to 260mm; F Low Density up to 450mm p. 4
Laser
Red laser diode, approx. 650nm, rotating polygon mirror wheel p. 2
Connectors
SUB-D 15-pin, or LP circuit board connector to MA 2/MA 4; cable 0.8m or 3.0m p. 4
Bar codes
2/5 Interleaved, Code 39, Code 93, Code 128, EAN 128, EAN/UPC, EAN Adendum, Codabar, Pharma Code p. 2
Dimensions
82x68x28mm p. 2
Weight
180g, 260g with cable p. 2
Housing
Plastic ABS / PC, IP 65 p. 1, 2
Accessories
Mounting systems (BT ...) and modular connector units MA ..., available separately p. 1
Networking
Integrated multiNet and daisy-chain network functionality p. 1

What this sheet walks you through

  • Reading the type key to order the right beam exit, cable, connector, optics and interface p. 4
  • Reading curves for the N, M and F optics p. 3
  • Pin assignments of the Sub-D cable and the two system connector cable p. 1
  • Meaning of the PWR, ERR and DEC LEDs p. 2
  • Mounting dimensions and optical axes p. 1

Good to know

  • The mounting thread has a maximum thread depth of 4mm. p. 1
  • The sheet states the laser is class 2 to EN 60825-1 and class II to 21 CFR 1040.10. p. 2

Questions this sheet answers

What is the difference between the Leuze BCL 21 and BCL 22?

The BCL 21 has an RS 485 host interface and the BCL 22 an RS 232 one; the BCL 22 also has two switching inputs and outputs to the BCL 21's one each. p. 2, 4

What voltage does the Leuze BCL 21/22 need?

10 to 30 VDC, with a maximum power consumption of 3.2W. p. 2

How far can the BCL 22 read barcodes?

It depends on the optics: up to 95mm for N (High Density), 260mm for M and 450mm for F (Low Density). p. 4

How fast does the Leuze BCL 21 scan?

1000 scans/s with M-Optics and 800 scans/s with N or F optics. p. 2

The file

Size and text

Pages4
PDF337 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Leuze BCL-21 and BCL-22 Spec Sheet

The text of page 1, from the PDF itself

Leuze electronic BCL 21/22

Barcode readerPart No. 501 07795Dimensioned drawing

RS 232 RS 485 10 - 30 V DC

z Scanning rate 1000scans/s (M-Optics) z Automatic detection of code type and code quality z Raster scanner or single-line scanner versions z Parameters are stored fail-safe z Reference code comparison function z Interfaces are freely configurable z Up to 2 switching inputs and 2 switching outputs each z Simple mounting and fastening z Integrated multiNet and daisy-chain network functionality

A B C D

Mounting thread with thread depth of max. 4mm Optical axis (perpendicular beam exit - 90°) Optical axis (straight beam exit - 0°) Laser beam, opening angle adjustable

Electrical connection We reserve the right to make changes • bcl_21_22_gb.fm

Cable with Sub-D connector

IP 65C IEC 60068...1 2 3 4 5 6 7 8SH 9 10 11 12 13 14 15

Accessories
PIN

BCL 21 Signal

(available separately)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SH

RS 485 GND SWIN1 RS 485 A RS 485 B /MA0 /MA1 /Serv VIN /MA4 SWOUT1 RxD_Serv TxD_Serv /MA2 /MA3 GNDIN Shield

z Mounting systems (BT …) z Modular connector units MA … (see separate data sheets)

Leuze electronic GmbH + Co. KG www.leuze.de

10-pol. (ZHR10)6-pol. (ZHR6)Sub-D 15-pol. - maleUL US LISTED

Cable with 2 system connectors

BCL 22 Signal Res. SWIN1 RS 232 CTS RS 232 RTS Res. SWOUT2 /Serv VIN SWIN2 SWOUT1 RS 232 RxD RS 232 TxD Res. Res. GNDIN Shield

PIN ZHR10ColourBCL 21 SignalBCL 22 Signal1 2 3 4 5 6 7 8 9 10

br/BN rt/RD or/OG ge/YE gn/GN bl/BU vi/VI gr/GY ws/WH SH

RS 485 GND RS 485 A RS 485 B RxD_Serv TxD_Serv /Serv SWIN1 VIN GNDIN PE

Res. RS 232 CTS RS 232 RTS RS 232 RxD RS 232 TxD /Serv SWIN1 VIN GNDIN PE

/MNA0 /MNA1 /MNA2 /MNA3 /MNA4 SWOUT1

Res. SWOUT2 Res. Res. SWIN2 SWOUT1

ZHR6 1 2 3 4 5 6

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

ws-br/WH-BN ws-rt/WH-RD ws-or/WH-OG ws-ge/WH-YE ws-gn/WH-GN ws-sw/WH-BK

BCL 21/22 … - 01

Page 2 of Leuze BCL-21 and BCL-22 Spec Sheet

The text of page 2, from the PDF itself

Leuze electronic BCL 21/22 Specifications

Tables

Optical data Light source Laser class Resolution / scanning rate Beam deflection Read distance Reading field opening Grid (R1) Grid field

Optical window Code types

laser diode, red, approx. 650nm class 2 acc. to EN 60825-1, class II acc. to 21 CFR 1040.10 with Laser Notice No. 50 N-Optics: m = 0.15mm … 0.5mm / 800 scans/s M-Optics: m = 0.2mm … 0.8mm / 1000 scans/s F-Optics: m = 0.5mm … 1.0mm / 800 scans/s by means of rotating polygon mirror wheel 50 … 450mm (depending on type of optics: see reading curves) 70mm at 50mm distance 10 lines the distance from the first to the last laser beam is specified in relation to the distance to the scanner: 16mm at a scanner distance of 100mm, 29mm at a scanner distance of 200mm, 42mm at a scanner distance of 300mm, 55mm at a scanner distance of 400mm glass with scratch-resistant Indium coating 2/5 Interleaved, Code 39, Code 93, Code 128, EAN 128, EAN/UPC, EAN Adendum, Codabar, Pharma Code

Electrical data Interface type Baud rate Data formats Service interface Ports Operating voltage Power consumption

BCL 21: RS 485 BCL 22: RS 232 adjustable: 110 … 115200Bd data bits: 7, 8, 9 parity: None, Even, Odd Stop bit: 1, 2 RS 232 with fixed data format,9600Bd 8 data bits, no parity, 1 stop bit BCL 21: 1 switching output, 1 switching input BCL 22: 2 switching outputs, 2 switching inputs 10 … 30VDC max. 3.2W

Diagrams

Mechanical data Protection class Weight Dimensions (W x H x D) Housing

IP 65 180g/260g with cable 82x68x28mm plastic ABS / PC

Environmental data Ambient temp. (operation/storage) Air humidity Vibration Shock Repeated shock Electromagnetic compatibility Certificates

0°C … +40°C/-20°C … +60°C max. 90% rel. humidity, non-condensing IEC 60068-2-6, test FC IEC 60068-2-27, Test Ea IEC 60068-2-29, test Eb EN 55022, IEC 61000-4-2, -3, -4 and -6 CE, UL

LED displays LED name LED colour State No voltage Initialisation (after reset) System ready Reading gate active Hardware error (defective motor, defective laser, defective system, etc.) autoConfig/teach-in Service interface active

Remarks PWR/Ready green

ERR/Error red

DEC/Decode yellow

off flashing (cycle1) on on off

off off off off onoff off off on -flashing (cycle1) on

flashing (cycle2) flashing (cycle2)

-

Notice! The flashing frequency is 5Hz; cycle2 is inverse to cycle1.

BCL 21/22 … - 01

0705

Page 3 of Leuze BCL-21 and BCL-22 Spec Sheet

The text of page 3, from the PDF itself

Leuze electronic BCL 21/22

Barcode reader

Reading curves BCL 21/22 with N-Optics and 800scans/s

BCL 21/22 with M-Optics and 1000scans/s

6015050 100

reading field width in mm

reading field width in mm

40 30 20 10 m = 0.150m = 0.2-10 -20 -30 -40500m = 0.2m = 0.3120160m = 0.5 m = 0.8-50-100-50 -60-150 01020304050607080901000204060Reading distance in mm80100140180200220240260Reading distance in mm

BCL 21/22 with F-Optics and 800scans/s 150

reading field width in mm

10050 m = 0.8 m = 1.0m = 0.50-50-100-150 04080120160200240280320360400440480Reading distance in mm

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

BCL 21/22 … - 01

Page 4 of Leuze BCL-21 and BCL-22 Spec Sheet

The text of page 4, from the PDF itself

Leuze electronic BCL 21/22 Type key

BCL Beam exit: 0 = perpendicular 2 = on the front side Length of connection cable: 0 = 0.8m 1 = 3.0m Connector: 2 = LP (circuit board connector to MA 2/MA 4…) 3 = SUB-D 15-pin Resolution / operating range: N = High Density up to 95mm M = Medium Density up to 260mm F = Low Density up to 450mm Reading characteristics: S = Single line scanner R1 = Raster scanner Host interface: 21 = RS 485 22 = RS 232

Order guide and accessories See technical description and/or price list!

BCL 21/22 … - 01

0705

More documents · 1

For the same models