Page 41
Leuze electronic
Installation
Circuitry MA 2 SE2
Switch
SE1 VDD_SE
SE
A GND_SE
Sensor
Load
10 … 30VDC
Figure 6.7:
13
SA2
14
SA1
16
GND_SA
17
V_IN
18
V_IN
19
GND_IN
20
GND_IN
ISA
Circuitry MA 2
TNT 35/7-24V
Position of the connectors in the MA 4/MA 4D
A B C D E
Setting of the device address Setting of the device address Service/operation switch Attached label with terminal assign. for RS232 Attached label with terminal assign. for RS485
Figure 6.8: Leuze electronic
F Terminal strip G Connection BCL H Service interface
Connector unit MA 4/MA 4D BCL 21/22
39
Page 42
Leuze electronic
Installation Wiring description
Terminals 1 to 6 as well as 23 and 24 in the MA 4/MA 4D are assigned as described below. For wiring through, the RS 485 interface at the MA 4/MA 4D is implemented twice:
Terminal 1 2 3 4 5 6 23 24 Table 6.7:
Signal RS 485 A RS 485 A RS 485 B RS 485 B GND 485 GND 485 RXD (service) TXD (service) Terminal assignment MA 4/MA 4D
Voltage supply In the connector unit MA 4/MA 4D, the connections for the voltage supply are implemented twice. This permits wiring through or the voltage supply of additional components. Terminal 17 18 19 20 21 22 Table 6.8:
Signal V_IN V_IN GND_IN GND_IN PE PE
Function Operating voltage 10 … 30VDC Operating voltage 10 … 30VDC Operating voltage 0VDC Operating voltage 0VDC Protective earth, grounding Protective earth, grounding
Terminal assignment voltage supply
Notice! It is imperative that the protective conductor PE also is wired through to avoid electromagnetic interference.
40
BCL 21/22
Leuze electronic
Page 43
Leuze electronic
Installation
Switching inputs 1 and 2 The connector unit MA 4/MA 4D has two switching inputs SE 1 and SE 2. • Input voltage: 12 … 30VDC Terminal 7 9
Signal SE2 SE1
11
VDD_SE
12
GND_SE
Table 6.9:
Function Switching input 2, 12 … 30VDC (with BCL 22 only) Switching input 1, 12 … 30VDC Supply voltage, switching input, equal to V_IN device GND, switching input, equal to GND_IN device
Terminal assignment switching inputs
Switching outputs 1 and 2 The MA 4/MA 4D is equipped with two switching outputs (SA1 and SA2) which can be programmed for various switching functions using the "BCLConfig" software. • Output voltage corresponds to operating voltage • Output current: Imax = 100mA The switching voltage for the output is generated by the operating voltage V_IN: • VDD_SA = VDD_IN • GND_SA = GND_IN Terminal 13 14 16
Leuze electronic
Function Switching output 2 (with BCL 22 only) Switching output 1 External supply voltage for switching output 0VDC
Terminal assignment switching outputs
BCL 21/22
TNT 35/7-24V
Table 6.10:
Signal SA2 SA1 GND_SA
41
Page 44
Leuze electronic
Installation Circuitry MA 4/MA 4D SE2
Switch
SE1 VDD_SE
SE
A GND_SE
Sensor
Load
10 … 30VDC
Figure 6.9:
42
13
SA2
14
SA1
16
GND_SA
17
V_IN
18
V_IN
19
GND_IN
20
GND_IN
ISA
Circuitry MA 4/MA 4D
BCL 21/22
Leuze electronic
Page 45
Leuze electronic
Installation
Position of the connectors in the MA 4 1xx/MA 4 D 1xx A F
B
G
C
H D E
MA 4x 100
MA 4x 110
MA 4x 120
MA 4x 130
D
Terminal strip
E
Attached label with terminal designation
TX + 1 TX - 2 RX+ 3 RX- 4 5 GND 6
TTY
Setting of the device address 0-15 or 16-31 Setting of the device address Interface module
RS422
1 2 3 4 5 6 TX + TX RX + RX G ND
2
1
3 4 5 6
R XD TX D C TS R TS GN D
RS232 p as . TX a k t. pa s. RX ak t.
F Service interface G Service/operation switch H Connection BCL Jumper TTY active/passive J (MA 4x 120 … only)
Figure 6.10: Connector unit MA 4 1xx/MA 4 D 1xx
Wiring description Terminals 1 to 6 in the MA 4 1xx/MA 4 D 1xx are assigned as described below. For wiring through, the RS 485 interface at the MA 4 100/MA 4 D 100 is implemented twice:
Terminal 1 2 3 4 5 6 Table 6.11:
Leuze electronic
Signal MA 4(D) 100 RS 485 A RS 485 A RS 485 B RS 485 B GND 485 GND 485
MA 4(D) 110 RXD TXD CTS RTS – GND
MA 4(D) 120 TX+ TXRX+ RX– GND
MA 4(D) 130 TX+ TXRX+ RX– GND
Terminal assignment MA 4 1xx/MA 4 D 1xx
BCL 21/22
43
TNT 35/7-24V
A B C
485A 1 485A 2 485B 3 485B 4 GND 5 GND 6
RS485
J
Page 46
Leuze electronic
Installation Notice!
The operating mode active/passive is selected via the two jumpers on the TTY interface module (MA 4 120/MA 4 D 120).
Voltage supply In the connector unit MA 4 1xx/MA 4 D 1xx, the connections for the voltage supply are implemented twice. This permits wiring through or the voltage supply of additional components. Terminal 17 18 19 20 21 22 Table 6.12:
Signal V_IN V_IN GND_IN GND_IN PE PE
Function Operating voltage 10 … 30VDC Operating voltage 10 … 30VDC Operating voltage 0VDC Operating voltage 0VDC Protective earth, grounding Protective earth, grounding
Terminal assignment voltage supply
Notice! It is imperative that the protective conductor PE also is wired through to avoid electromagnetic interference.
Switching inputs 1 and 2 The connector unit MA 4 1xx/MA 4 D 1xx has two switching inputs SE 1 and SE 2. • Input voltage: 12 … 30VDC Terminal 7 9
Signal SE2 SE1
11
VDD_SE
12
GND_SE
Table 6.13:
44
Function Switching input 2, 12 … 30VDC Switching input 1, 12 … 30VDC Supply voltage, switching input, equal to V_IN device GND, switching input, equal to GND_IN device
Terminal assignment switching inputs
BCL 21/22
Leuze electronic
Page 47
Leuze electronic
Installation
Switching outputs 1 and 2 The MA 4 1xx/MA 4 D 1xx is equipped with two switching outputs (SA1 and SA2) which can be programmed for various switching functions using the "BCLConfig" software. • Output voltage corresponds to operating voltage • Output current: Imax = 100mA The switching voltage for the output is generated by the operating voltage V+: • VDD_SA = V_IN • GND_SA = GND_IN Terminal 13 14 16 Table 6.14:
Signal SA2 SA1 GND_SA
Function Switching output 2 Switching output 1 External supply voltage for switching output 0VDC
Terminal assignment switching outputs
Circuitry MA 4 1xx/MA 4 D 1xx SE2
Switch
SE1 VDD_SE
SE
A GND_SE
Sensor
10 … 30VDC
SA2
14
SA1
16
GND_SA
17
V_IN
18
V_IN
19
GND_IN
20
GND_IN
ISA
TNT 35/7-24V
Load
13
Figure 6.11: Circuitry MA 4 1xx/MA 4 D 1xx
Leuze electronic
BCL 21/22
45
Page 48
Leuze electronic
Installation 6.3.3
Wire Lengths and Shielding The following maximum lengths for wires and the type of shielding to be used must be observed: Connection
Max. wire length
Shielding
BCL 21/22 - Service
RS 232
10m absolutely required, shield meshing
BCL 21/MA 2 - Host
RS 485
1200m absolutely required, flexible leads as twisted pairs
Switching inputs 1+2
–
10m not necessary
Switching outputs 1+2
–
10m not necessary
Table 6.15:
6.4
Interface
Wire Lengths and Shielding
Disassembling, Packing, Disposing Repacking For later re-use, the device is to be packed so that it is protected against shocks and dampness. Optimal protection is achieved when using the original packaging. Notice! Electrical scrap is a special waste product! Observe the locally applicable regulations regarding disposal of the product.
46