For the Leuze BCL-21 and Leuze BCL-22

Page 41

Leuze electronic

Installation

Circuitry MA 2 SE2

Switch

SE1 VDD_SE

SE

A GND_SE

Sensor

Load

10 … 30VDC

Figure 6.7:

13

SA2

14

SA1

16

GND_SA

17

V_IN

18

V_IN

19

GND_IN

20

GND_IN

ISA

Circuitry MA 2

TNT 35/7-24V

Position of the connectors in the MA 4/MA 4D

A B C D E

Setting of the device address Setting of the device address Service/operation switch Attached label with terminal assign. for RS232 Attached label with terminal assign. for RS485

Figure 6.8: Leuze electronic

F Terminal strip G Connection BCL H Service interface

Connector unit MA 4/MA 4D BCL 21/22

39

Page 42

Leuze electronic

Installation Wiring description

Terminals 1 to 6 as well as 23 and 24 in the MA 4/MA 4D are assigned as described below. For wiring through, the RS 485 interface at the MA 4/MA 4D is implemented twice:

Terminal 1 2 3 4 5 6 23 24 Table 6.7:

Signal RS 485 A RS 485 A RS 485 B RS 485 B GND 485 GND 485 RXD (service) TXD (service) Terminal assignment MA 4/MA 4D

Voltage supply In the connector unit MA 4/MA 4D, the connections for the voltage supply are implemented twice. This permits wiring through or the voltage supply of additional components. Terminal 17 18 19 20 21 22 Table 6.8:

Signal V_IN V_IN GND_IN GND_IN PE PE

Function Operating voltage 10 … 30VDC Operating voltage 10 … 30VDC Operating voltage 0VDC Operating voltage 0VDC Protective earth, grounding Protective earth, grounding

Terminal assignment voltage supply

Notice! It is imperative that the protective conductor PE also is wired through to avoid electromagnetic interference.

40

BCL 21/22

Leuze electronic

Page 43

Leuze electronic

Installation

Switching inputs 1 and 2 The connector unit MA 4/MA 4D has two switching inputs SE 1 and SE 2. • Input voltage: 12 … 30VDC Terminal 7 9

Signal SE2 SE1

11

VDD_SE

12

GND_SE

Table 6.9:

Function Switching input 2, 12 … 30VDC (with BCL 22 only) Switching input 1, 12 … 30VDC Supply voltage, switching input, equal to V_IN device GND, switching input, equal to GND_IN device

Terminal assignment switching inputs

Switching outputs 1 and 2 The MA 4/MA 4D is equipped with two switching outputs (SA1 and SA2) which can be programmed for various switching functions using the "BCLConfig" software. • Output voltage corresponds to operating voltage • Output current: Imax = 100mA The switching voltage for the output is generated by the operating voltage V_IN: • VDD_SA = VDD_IN • GND_SA = GND_IN Terminal 13 14 16

Leuze electronic

Function Switching output 2 (with BCL 22 only) Switching output 1 External supply voltage for switching output 0VDC

Terminal assignment switching outputs

BCL 21/22

TNT 35/7-24V

Table 6.10:

Signal SA2 SA1 GND_SA

41

Page 44

Leuze electronic

Installation Circuitry MA 4/MA 4D SE2

Switch

SE1 VDD_SE

SE

A GND_SE

Sensor

Load

10 … 30VDC

Figure 6.9:

42

13

SA2

14

SA1

16

GND_SA

17

V_IN

18

V_IN

19

GND_IN

20

GND_IN

ISA

Circuitry MA 4/MA 4D

BCL 21/22

Leuze electronic

Page 45

Leuze electronic

Installation

Position of the connectors in the MA 4 1xx/MA 4 D 1xx A F

B

G

C

H D E

MA 4x 100

MA 4x 110

MA 4x 120

MA 4x 130

D

Terminal strip

E

Attached label with terminal designation

TX + 1 TX - 2 RX+ 3 RX- 4 5 GND 6

TTY

Setting of the device address 0-15 or 16-31 Setting of the device address Interface module

RS422

1 2 3 4 5 6 TX + TX RX + RX G ND

2

1

3 4 5 6

R XD TX D C TS R TS GN D

RS232 p as . TX a k t. pa s. RX ak t.

F Service interface G Service/operation switch H Connection BCL Jumper TTY active/passive J (MA 4x 120 … only)

Figure 6.10: Connector unit MA 4 1xx/MA 4 D 1xx

Wiring description Terminals 1 to 6 in the MA 4 1xx/MA 4 D 1xx are assigned as described below. For wiring through, the RS 485 interface at the MA 4 100/MA 4 D 100 is implemented twice:

Terminal 1 2 3 4 5 6 Table 6.11:

Leuze electronic

Signal MA 4(D) 100 RS 485 A RS 485 A RS 485 B RS 485 B GND 485 GND 485

MA 4(D) 110 RXD TXD CTS RTS – GND

MA 4(D) 120 TX+ TXRX+ RX– GND

MA 4(D) 130 TX+ TXRX+ RX– GND

Terminal assignment MA 4 1xx/MA 4 D 1xx

BCL 21/22

43

TNT 35/7-24V

A B C

485A 1 485A 2 485B 3 485B 4 GND 5 GND 6

RS485

J

Page 46

Leuze electronic

Installation Notice!

The operating mode active/passive is selected via the two jumpers on the TTY interface module (MA 4 120/MA 4 D 120).

Voltage supply In the connector unit MA 4 1xx/MA 4 D 1xx, the connections for the voltage supply are implemented twice. This permits wiring through or the voltage supply of additional components. Terminal 17 18 19 20 21 22 Table 6.12:

Signal V_IN V_IN GND_IN GND_IN PE PE

Function Operating voltage 10 … 30VDC Operating voltage 10 … 30VDC Operating voltage 0VDC Operating voltage 0VDC Protective earth, grounding Protective earth, grounding

Terminal assignment voltage supply

Notice! It is imperative that the protective conductor PE also is wired through to avoid electromagnetic interference.

Switching inputs 1 and 2 The connector unit MA 4 1xx/MA 4 D 1xx has two switching inputs SE 1 and SE 2. • Input voltage: 12 … 30VDC Terminal 7 9

Signal SE2 SE1

11

VDD_SE

12

GND_SE

Table 6.13:

44

Function Switching input 2, 12 … 30VDC Switching input 1, 12 … 30VDC Supply voltage, switching input, equal to V_IN device GND, switching input, equal to GND_IN device

Terminal assignment switching inputs

BCL 21/22

Leuze electronic

Page 47

Leuze electronic

Installation

Switching outputs 1 and 2 The MA 4 1xx/MA 4 D 1xx is equipped with two switching outputs (SA1 and SA2) which can be programmed for various switching functions using the "BCLConfig" software. • Output voltage corresponds to operating voltage • Output current: Imax = 100mA The switching voltage for the output is generated by the operating voltage V+: • VDD_SA = V_IN • GND_SA = GND_IN Terminal 13 14 16 Table 6.14:

Signal SA2 SA1 GND_SA

Function Switching output 2 Switching output 1 External supply voltage for switching output 0VDC

Terminal assignment switching outputs

Circuitry MA 4 1xx/MA 4 D 1xx SE2

Switch

SE1 VDD_SE

SE

A GND_SE

Sensor

10 … 30VDC

SA2

14

SA1

16

GND_SA

17

V_IN

18

V_IN

19

GND_IN

20

GND_IN

ISA

TNT 35/7-24V

Load

13

Figure 6.11: Circuitry MA 4 1xx/MA 4 D 1xx

Leuze electronic

BCL 21/22

45

Page 48

Leuze electronic

Installation 6.3.3

Wire Lengths and Shielding The following maximum lengths for wires and the type of shielding to be used must be observed: Connection

Max. wire length

Shielding

BCL 21/22 - Service

RS 232

10m absolutely required, shield meshing

BCL 21/MA 2 - Host

RS 485

1200m absolutely required, flexible leads as twisted pairs

Switching inputs 1+2

–

10m not necessary

Switching outputs 1+2

–

10m not necessary

Table 6.15:

6.4

Interface

Wire Lengths and Shielding

Disassembling, Packing, Disposing Repacking For later re-use, the device is to be packed so that it is protected against shocks and dampness. Optimal protection is achieved when using the original packaging. Notice! Electrical scrap is a special waste product! Observe the locally applicable regulations regarding disposal of the product.

46

BCL 21/22

Leuze electronic