Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 12

BCL 21/22 Bar Code Reader with Integrated Decoder and Connector Unit MA 2 / MA 4... Technical Description: 6 Installation, pages 33 to 40

Pages 33 to 40 of 84, from BCL 21/22 Bar Code Reader with Integrated Decoder and Connector Unit MA 2 / MA 4... Technical Description

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze BCL-21 and Leuze BCL-22

Page 33

Leuze electronic 6

Installation

6.1

Storage, Transportation

Installation

Attention! When transporting, package the device so that it is protected against collision and humidity. Optimal protection is achieved when using the original packaging. Heed the required environmental conditions specified in the technical data.

Unpacking ! Check the packaging for any damage. If damage is found, notify the post office or shipping agent as well as the supplier. ! Check the delivery contents using your order and the delivery papers: • • • • delivered quantity device type and model as indicated on the nameplate accessories operating manual

The name plate provides information as to what BCL type your device is. For specific information, please refer to chapter 4.4.1.

Figure 6.1:

Device name plate BCL 21/22

! Save the original packaging for later storage or shipping. If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office. ! Observe the applicable local regulations when disposing of the packaging materials.

Cleaning ! Clean the glass window of the BCL 21/22 with a soft cloth before mounting. Remove all packaging remains, e.g. carton fibres or Styrofoam balls. Attention! Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device.

Leuze electronic

BCL 21/22

31

TNT 35/7-24V

Name plates, BCL-models

Page 34

Leuze electronic

Installation 6.2

Mounting Attention Laser Radiation! Follow the safety notices in chapter 2.3 on page 7! Mounting devices are available which have to be ordered separately as accessory at Leuze electronic. For order numbers, see chapter 5. The mounting devices BT 20/BT 21 are suitable both for rod mounting (d = 12mm) and for mounting using a sheet metal clamp if the sheet metal is 1.5 … 3mm thick. Otherwise, the mounting threads at the back and bottom side of the device are suitable for installation of the BCL 21/22 according to its area of application.

Mounting example BCL 21/22

Fastening thread

Mounting device BT20

Figure 6.2:

Mounting example BCL 21/22

Mounting MA 2/MA 4… You can mount the connector units MA 2/MA 4… individually through the holes Ø 5mm located on the mounting plate (see figure 5.2 and figure 5.4). Then connect the BCL 21 with the connector unit MA 2/MA 4… as described in chapter 6.3.2.

32

BCL 21/22

Leuze electronic

Page 35

Leuze electronic 6.2.1

Installation

Device Arrangement Selecting a mounting location In order to select the right mounting location, several factors must be considered: • size, orientation, and position tolerance of the barcodes on the objects to be scanned • the reading field of the BCL 21/22 in relation to the bar code module width • the resulting minimum and maximum reading distance from the respective reading field For specific information, please refer to chapter 4.4. Notice! The best reading results are obtained when • the bar code is moved along the reading window at an angle of approx. 9 … 15°. • the reading distance lies in the middle area of the reading field. • you do not use high-gloss labels.

TNT 35/7-24V

Application examples

Figure 6.3:

Applications with perpendicular and front side beam exit

Mounting location ! When selecting a mounting location, pay attention to • maintaining the required environmental conditions (temperature, humidity) • possible soiling of the reading window due to liquids, abrasion by boxes, or packaging material residues. • lowest possible chance of damage to the scanner by mechanical collision or jammed parts.

Leuze electronic

BCL 21/22

33

Page 36

Leuze electronic

Installation 6.3

Connection Attention! Do not open the device yourself under any circumstances! There is otherwise a risk of uncontrolled emission of laser radiation from the device. The housing of the BCL 21/22 contains no parts that need to be adjusted or maintained by the user. Before connecting the device, be sure that the supply voltage agrees with the value printed on the nameplate. Connection of the device and maintenance work while under voltage must only be carried out by a qualified electrician. The power supply unit for the generation of the supply voltage for the BCL 21/22 and the MA 2/MA 4… must have a secure electrical insulation through double insulation and safety transformers according to EN 60742/IEC 60742 (functional low voltage). Be sure that the earthing conductor is connected correctly. Error-free operation is only guaranteed when the device is properly earthed. If faults cannot be corrected, the device should be removed from operation and protected against possible use.

6.3.1

Connection BCL 21/22 stand alone BCL 21/22 Sub D-pin assignments GND_485 /MA4 SWOUT1 RXD_Serv

BCL 21 (RS 485)

TXD_Serv /MA2 /MA3 GNDIN

SWIN1 RS485_A RS485_B /MA0 /MA1 /Serv VIN

Res. SWIN2 SWOUT1 RXD

BCL 22 (RS 232)

TXD Res. Res. GNDIN

SWIN1 CTS RTS Res. SWOUT2 /Serv VIN

Figure 6.4: 34

BCL 21/22 Sub-D pin assignments BCL 21/22

Leuze electronic

Page 37

Leuze electronic

Installation

Wiring description BCL 21 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 Pin 15 Metal flange

GND 485 SWIN1 RS485_A RS485_B /MA0 /MA1 /Serv VIN /MA4 SWOUT1 RXD_Serv TXD_Serv /MA2 /MA3 GNDIN PE

Table 6.1:

Switching input 1, 12 … 30VDC, (see figure 6.7) Signal line A, host interface RS 485 Signal line B, host interface RS 485 Address selection bit0 Address selection bit1 Bridge to pin 15: service operation via RS 232 interface Supply voltage +10 … 30VDC Address selection bit4 Switching output 1 RXD signal, service interface RS 232 TXD signal, service interface RS 232 Address selection bit2 Address selection bit3 Supply voltage 0VDC Shielding (the shielding of the sub-D-cable is connected with the flange of the connector casing)

Wiring description BCL 21

Wiring description BCL 22 Res. SWIN1 CTS RTS Res. SWOUT2 /Serv VIN SWIN2 SWOUT1 RXD TXD Res. Res. GNDIN PE

Table 6.2:

Reserved Switching input 1, 12 … 30VDC, (see figure 6.7) CTS signal, host interface RS 232 RTS signal, host interface RS232 Reserved Switching output 2 Bridge with pin 15: service operation Supply voltage +10 … 30VDC Switching input 2, 12 … 30VDC Switching output 1 RXD signal, service interface RS 232 TXD signal, service interface RS 232 Reserved Reserved Supply voltage 0VDC Shielding (the shielding of the sub-D-cable is connected with the flange of the connector casing)

TNT 35/7-24V

Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 Pin 15 Metal flange

Wiring description BCL 22

Switching inputs A read process can be triggered by applying a voltage of 12 … 30VDC to the switched input connections SWIN1 and SWIN2.

Leuze electronic

BCL 21/22

35

Page 38

Leuze electronic

Installation 6.3.2

Connection BCL 21 with MA 2/MA 4… (RS 485) Connection of the BCL is considerably easier when using the MA 2/MA 4…. The BCL 21 is alternately equipped with flat connectors which enable connection to the MA 2/MA 4… connector unit. The following figure shows the combination of the two devices.

BCL 21 and MA 2/MA 4…

Figure 6.5:

BCL 21 with connector unit MA 2/MA 4…

Open MA 2/MA 4… casing ! Unscrew the four screws on the front side of the MA 2/MA 4… and carefully lift off the lid of the housing. Now you have proper access to all components within the connector unit. Notice! All electrical connections can be carried out on the terminal strip quickly and without screwing down or soldering. Wires with ferruled ends can be inserted directly into the terminal without depressing the clamping lever.

36

BCL 21/22

Leuze electronic

Page 39

Leuze electronic

Installation

Position of the connectors in the MA 2 Setting of the device address MA 2

Service interface

ADR SERVICE

0-15 16-31

Connector for BCL 21 SERV

Terminal strip

GND_SA

V_IN

V_IN

20

21

22

PE

SA2

19

PE

18

GND_IN

17

GND_IN

13 14 16

SA1

SE2

11 12

Switching Switching input output

Brass clamp for shield/PE

Figure 6.6:

9

GND_SE

7

SE1

1 2 3 4 5 6

VDD_SE

23 24

RS485A RS485A RS485B RS485B GND485 GND485

Attached label with terminal designation

RXD TXD

BCL 21

Voltage supply 10 … 30VDC

Connector unit MA 2

Wiring description

Terminal 1 2 3 4 5 6 23 24 Table 6.3:

Leuze electronic

TNT 35/7-24V

Terminals 1 to 6 as well as 23 and 24 in the MA 2 are assigned as described below. For wiring through, the RS 485 interface at the MA 2 is implemented twice:

Signal RS 485 A RS 485 A RS 485 B RS 485 B GND 485 GND 485 RXD (service) TXD (service) Terminal assignment MA 2

BCL 21/22

37

Page 40

Leuze electronic

Installation Voltage supply

In the connector unit MA 2, the connections for the voltage supply are implemented twice. This permits wiring through or the voltage supply of additional components. Terminal 17 18 19 20 21 22 Table 6.4:

Signal V_IN V_IN GND_IN GND_IN PE PE

Function Operating voltage 10 … 30VDC Operating voltage 10 … 30VDC Operating voltage 0VDC Operating voltage 0VDC Protective earth, grounding Protective earth, grounding

Terminal assignment voltage supply

Notice! It is imperative that the protective conductor PE also is wired through to avoid electromagnetic interference.

Switching inputs 1 and 2 The MA 2 connector unit is equipped with two switching inputs SE 1 and SE 2 (SE 2 can only be activated with BCL 22). • Input voltage: 12 … 30VDC Terminal 7 9 11 12 Table 6.5:

Signal SE2 SE1

Function Switching input 2, 12 … 30VDC Switching input 1, 12 … 30VDC Supply voltage, switching input, VDD_SE equal to V_IN device Supply voltage, switching input, GND_SE equal to GND_IN device Terminal assignment switching inputs

Switching outputs 1 and 2 The MA 2 is equipped with 2 switching outputs SA1 and SA2 (SA 2 can only be activated with BCL 22) which can be programmed for various switching functions using the "BCLConfig" software. • Output voltage corresponds to operating voltage • Output current: Imax = 100mA The switching voltage for the output is generated by the operating voltage V_IN: • VDD_SA = VDD_IN • GND_SA = GND_IN Terminal 13 14 16 Table 6.6:

38

Signal SA2 SA1 GND_SA

Function Switching output 2 Switching output 1 External supply voltage for switching output 0VDC

Terminal assignment switching outputs

BCL 21/22

Leuze electronic