For the Leuze BCL-21 and Leuze BCL-22

Page 11

Leuze electronic 3

Description

Description BCL 21/22 device construction Mounting slider Reading window

Cable with 15-pin Sub-D connector (BCL 22) or with panel connectors for connection to MA 2/MA 4…

Two mounting threads M3 each (4mm thread depth) on the rear and bottom side of the device

Figure 3.1:

3.1

BCL 21/22 device construction

The Bar Code Readers BCL 21/22

The many possible configurations allow the adaptation of the device to a multitude of reading tasks. Due to the small dimensions, the BCL 21/22 may also be used in highly constrained spaces. The low weight permits the installation into machines that were not designed for heavy components. The various beam exits (perpendicular/front side) extend the area of application of the BCL 21/22 and help it to adapt. The connector units MA 2/MA 4… offer simple electrical installation in conjunction with the BCL 21. Information on technical data and characteristics can be found in chapter 4.

BCL 22 "stand alone" The bar code reader BCL 22 is operated as a "stand-alone" device. The BCL features a cable for the electrical connection of the supply voltage, the interface, and the switching inputs.

BCL 21 with MA 2 If several BCLs are to be networked, the use of a connector unit MA 2/MA 4… is recommended for each BCL 21. Electrical connection, commissioning, and service can be comfortably carried out in a short period of time. BCL 21 and MA 2/MA 4… are arranged separately. The two devices are connected by a cable.

Leuze electronic

BCL 21/22

9

TNT 35/7-24V

The bar code readers BCL 21/22 are high-speed scanners with integrated decoder for all bar codes currently in use, e.g. 2/5 Interleaved, EAN etc.

Page 12

Leuze electronic

Description 3.1.1

Networking Up to 30 scanners can be networked via the connector unit MA 2 and a bus master MA 30/ 31. For this, every BCL 21 is assigned its own hardware address in the corresponding MA 2. The devices are networked by connecting the individual RS 485 interfaces in parallel.

multiNet plus In the Leuze multiNet plus, the individual network devices sequentially transfer their data to the network master MA 30/31 when requested. In addition, every bus node declared a slave receives a device address which is adjusted in the corresponding MA 2/MA 4… via a coding switch. The device address remains in the MA 2/MA 4… when the scanner is replaced. The master then transmits the data of all network devices via its host interface to a primary PLC control system or a computer, i.e. it "collects" the scanner data in the network and transmits them to an interface on the host computer. This reduces interface costs (CPs) and time spent programming the software.

Networking via multiNet plus Host (PLC, process, etc.)

Slave 1 MA 2 RS 232 RS 422 RS 485 or TTY

- backup - parameter

Slave 2 MA 2 Network master multiNet plus

Voltage supply

MA30/31 Slave 3 MA 2

RS 485

Figure 3.2:

10

Networking possibilities using the multiNet plus (BCL 21)

BCL 21/22

Leuze electronic

Page 13

Leuze electronic

Description

Two-wire RS 485 The Leuze multiNet plus is optimised for fast transmission of scanner data to a primary host computer. The multiNet plus consists physically of a two-wire RS 485 interface through which the multiNet plus software protocol is controlled. This makes wiring the network easy and inexpensive as slaves are connected to one another in parallel.

Interface modules

TNT 35/7-24V

Shielded, twisted pair conductors should be used for the multiNet. This allows a total network length of up to 1200 m. Connection of the network to the primary computer is made via the host interface of the MA 30/31 which can be equipped with 4 different physical interface modules. The available options are modules for RS 422, RS 232, TTY or RS 485.

Leuze electronic

BCL 21/22

11