For the Leuze BCL-21 and Leuze BCL-22

Page 56

Leuze electronic

Important Parameters

10

Important Parameters

10.1

Code menu

Figure 10.1: Standard setting of the code menu Code table

Here, the codes which are to be decoded are set. We recommend enabling only the code types which are to actually be read with the corresponding element numbers. Important: Code 1 must always be selected. If multiple code types are to be used, set in sequential order: Code 1, Code 2, …

Number Of Digits

In the field Element number, up to 3 element entries may be entered. An area is represented by a dashed line: e.g. 4-40 digits. With 2 or 3 different element entries by a comma: e.g: 8,13 digits The combination is also possible, but the range must be specified first: e.g.: 4-10,20 digits

Notice! If the code EAN128 is to be read, 3 additional characters are to be set for the code identifier. Properties

Behind the "Properties" button, to the right of the respective code, the code-specific settings, such as the check digit, can be selected.

Number of bar Here, the number of the bar codes to be decoded within a read cycle (one codes reading gate) is set.

54

BCL 21/22

Leuze electronic

Page 57

Leuze electronic

Important Parameters

10.1.1 Properties of the Code menu

Figure 10.2: Standard setting of the properties of the code menu Quiet zone: the area to the left and right of the bar code Module: width of the narrowest line in the bar code According to the code specifications, each bar code must have a quiet zone which is 10 times as wide as the module of the bar code. Ex: for a code having a module of 0.5mm, 5mm blank space must be present at both the left and right of the code. By default, the scanner checks a quiet zone which is 7 times greater than the module. This means that 7 times or greater is o.k.

Reading security Specifies how often a code must be decoded before the result is valid (Equal Scans) and output. This value should be increased for inspection and test purposes only. No time correlation

No position correlation

If this parameter is set, a gap between two identical labels is ignored and they are treated as a single label.

If this parameter is set, then the position of a bar code label in the reading beam is not taken into account. Identical labels are treated as a single label

Notice! In general, the remaining parameters must not be changed. In the worst case, this could corrupt the reading result!

Leuze electronic

BCL 21/22

55

TNT 35/7-24V

Quiet zone size

Page 58

Leuze electronic

Important Parameters 10.2

Output menu

Figure 10.3: Output menu Output header

Select from the options listed below. The output header is sent in a separate message before the read result.

Label header

The Label header is set directly before the code data.

Label footer

The label footer is appended directly to the code data.

Message mode

Selects whether the bar codes read are sent in concatenation or separately as individual strings.

Notice! The structure of this message string is depicted symbolically in the preview window.

56

No read string

This character is set for each unrecognised bar code. Multiple characters (=string) may be entered here. Up to 20 characters are possible.

Properties

Set the desired formatting modes and formatting characters as necessary.

BCL 21/22

Leuze electronic

Page 59

Leuze electronic 10.3

Important Parameters

Control

Figure 10.4: Control menu default settings

Activation

Autostart after decoding

In this mode, the scanner reads via an internal trigger signal with maximum performance. Attention: Up to 100 codes per second may be transmitted.

Command character

The standard online character for the trigger start is the ´+´ character. This character can be changed only via the tree structure.

Decode delay time This point is usually used only for test purposes. After the time set here has passed, the scanner automatically reactivates itself following a reading gate end.

Leuze electronic

BCL 21/22

57

TNT 35/7-24V

Sensor 1 function see menu "switching input"

Page 60

Leuze electronic

Important Parameters Deactivation Sensor 1 function see menu "switching input" Reading security reached (equal scans)

If this item is activated, the read result is output immediately after the bar code is decoded. If the item is deactivated, the read result is sent only after the trigger signal is returned (=end of reading gate).

Command character

The standard online character for the trigger end is the ´-´ character. This character can be changed only via the tree structure.

Time

For test purposes. If the scanner is activated, the reading gate is automatically closed by the scanner after this preset time has elapsed.

Scans without info Following a successful read, the scanner waits for this number of scans (sequential scans with no read result) before it automatically deactivates itself.

10.4

Communication

Figure 10.5: Standard setting of the communication menu Select the desired baud rate, the stop bits, the data bits and the parity here. In addition, several different handshake modes and protocols can be set here.

58

BCL 21/22

Leuze electronic

Page 61

Leuze electronic

Important Parameters

The RK512/3964 protocol can also be selected here. The individual parameters for this protocol can be found in the tree-structure configuration: Communication -> Customer Interface -> 3964 / RK 512 Protocol Attention! If the BCL 21 is operated in a network ("Leuze multiNet"), no changes may be made here. The scanner automatically sets itself to the multiNet protocol!

Figure 10.6: Standard setting of the property menu Here, the frame format (prefix/postfix), the address mode as well as a BCC mode can be set. Attention! If the BCL 21 is operated in a network ("Leuze multiNet"), no changes may be made here.

Leuze electronic

BCL 21/22

59

TNT 35/7-24V

10.4.1 Communication properties

Page 62

Leuze electronic

Important Parameters 10.5

Reference code

Figure 10.7: Reference code menu A reference code is bar code information which is stored in the memory of the scanner. This reference code can be compared with the current decoded bar code in various modes and, thus, the switching output be set appropriately. To do this, the switching output must still be set to "By comparison of reference code X" in the "Switch" menu. One way to store the reference code is to enter it manually in this menu. You can find further options of the reference code teach-in in the chapter on online commands.

60

Type

Select the code type.

Info

Contents of the reference code

Compare mode

Select here how the internally stored reference code is to be compared with the decoded result. -> For additional comparison possibilities, please select the "Properties" menu

BCL 21/22

Leuze electronic

Page 63

Leuze electronic 10.6

Important Parameters

Switching input

Invert

Here, the input level can be inverted.

Enable

Switching input enabled or disabled.

Debounce time

This time period must lapse until the trigger signal is regarded as valid.

Delay on time

The trigger signal is passed on delayed by the specified time period.

Pulse duration

If the value is higher than "0": duration of the activation, regardless of how long the trigger signal has been present.

Delay off time

After the end of the trigger signal, the pulse is extended internally by this time period.

Notice! If the switch-off delay is activated, the parameter "pulse duration" should be "0".

Function

Leuze electronic

Event that is started when the switching input is activated.

BCL 21/22

61

TNT 35/7-24V

Figure 10.8: Standard setting of the switching input menu

Page 64

Leuze electronic

Important Parameters 10.7

Switching output

Figure 10.9: Standard setting of the switching output menu

62

Activation

Select the desired event which is to initiate the switching of the switching output here. Multiple events can also be simultaneously activated.

Deactivation

Shown here is the event which results in the switching output being reset (if the set pulse duration has not yet expired). Multiple events can also be simultaneously activated.

Invert

Level inverted

Pulse duration

Duration of the switching output impulse. A value of "0" in this position indicates a static level, i.e., the signal remains present until the deactivation event occurs.

BCL 21/22