Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Operating Instructions: CLV 42x Bar Code Scanner, Standard line

Manual · Sick

Operating Instructions: CLV 42x Bar Code Scanner, Standard line

Manual146 pagesPDF 3.7 MB

Operating instructions for the SICK CLV 420, CLV 421 and CLV 422 fixed-mount line and raster bar code scanners.

Download the PDF3.7 MB

Covers · 2 models

The models it covers

Summary

What is in it

The operating instructions for the SICK CLV 42x family of fixed-focus line and raster bar code scanners: the CLV 420 (standard), CLV 421 (long range) and CLV 422 (high density), each also offered with a 105 degree angle attachment. It covers safety, the product and its variants, installation and alignment, electrical connection through the CDB 420 or CDM 420 connection module, startup and configuration with the CLV Setup software or AutoSetup, operating modes, maintenance, troubleshooting, technical data and reading field diagrams.

Its parts

  1. Notes on this document
  2. Safety information
  3. Product description
  4. Installation
  5. Electrical connection
  6. Operation
  7. Maintenance
  8. Troubleshooting
  9. Technical data

From the manual

Key facts from this manual

Each line names its page in the PDF.

Operating instructions (2004) for the SICK CLV 42x Standard line fixed focus bar code scanners, which cover the CLV 420 (standard), CLV 421 (long range) and CLV 422 (high density). They explain installation, electrical connection through the CDB 420 or CDM 420 connection modules, configuration, error messages and troubleshooting. Technical data and an accessories list with part numbers are included.

Read for this summary: pages 1 to 3, 19 to 20, 25, 41 to 42, 51 to 52, 80 to 81, 89 to 90 and 130 to 131 of 146.

Device
Fixed focus laser bar code scanner, line or raster type; CLV 420 standard, CLV 421 long range, CLV 422 high density p. 89
Connector
15-pin D Sub HD connector on a 0.9 m (35.5 in) cable p. 90
Power
10 to 30 V DC, 3.5 W p. 90
Data interfaces
Host: RS 232 or RS 422/485, 300 to 57,600 bd, SICK Standard or 3964(R); CAN: CANopen, CAN Scanner Network; terminal: RS 232, 9,600 bd p. 89, 90
Inputs and outputs
2 optodecoupled switching inputs (Sensor 1, Sensor 2); 2 PNP switching outputs (Result 1, Result 2), 100 mA max p. 90
Scanning
Red laser, 650 to 670 nm; 400 to 1,200 Hz scanning/decoding frequency; aperture angle max. 50° p. 89
Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode p. 89
Scan variants
Line (-0010) or raster with 8 lines (-1010); -2010 and -3010 add a 105° angle attachment p. 19, 25
Weight
250 g (8.8 oz) with cable; approx. 320 g (11.3 oz) with the 105° angle attachment p. 90
Temperature
Operating 0 to +40 °C, storage –20 to +70 °C; humidity max. 90 % non condensing p. 90
Housing
Zinc die-cast, IP 65 (to DIN 40 050) p. 90
Connection modules
CDB 420-001 (1 023 885), CDM 420-0001 (1 025 362), CDM 420-0101 (1 025 364) p. 130
Cables
Extension cable to CDB/CDM 420, 2 m: 6 010 075; cable with open end, 2 m: 6 010 137; RS 232 null modem cable, 3 m: 2 014 054 p. 131
Firmware and software
Firmware V1.70 O078; CLV Setup V 4.1 O508 (Windows) p. 2

What this manual walks you through

  • Scope of delivery and what is needed to run the scanner p. 19, 20
  • Configuring with the CLV Setup program or command strings p. 25
  • Connecting the scanner through a CDB 420 or CDM 420 connection module p. 41, 42
  • Pin assignment of the 15-pin D Sub HD plug p. 42
  • Starting up with the factory default settings p. 51, 52
  • Reading and clearing error messages p. 80, 81
  • Technical data for the CLV 420, 421 and 422 p. 89, 90
  • Accessories: brackets, connection modules, fieldbus gateways and cables p. 130, 131

Good to know

  • The manual states the CLV 42x is UL certificated only when a class 2 power supply according to UL 1310 is used. p. 2
  • A non-SICK power supply must give 10 to 30 V DC and at least 4 W. p. 20
  • With the Sensor 1 and serial interface pulse types in Reading mode, the laser diode shuts off after 10 min. p. 89
  • The two switching inputs are not interchangeable; Vimax is 28 V. p. 90
  • If a CLV SYS-Failure error comes back after the restart, the device needs SICK Service. p. 80

Questions this manual answers

What power supply does the SICK CLV 422 need?

10 to 30 V DC; it draws 3.5 W. A non-SICK supply must deliver at least 4 W, connected with cable 6 010 137. p. 20, 90

What does "CLV SYS-Failure" mean on a CLV 420?

The scanner found a system error (RAM, mirror wheel speed, mirror interval or laser shutter) and restarts; if it happens again, contact SICK Service. p. 80

What is on the CLV 42x 15-pin connector?

Power, the terminal interface, the RS 232 or RS 422/485 host interface, CAN, two switching inputs and two switching outputs. p. 41, 42

What are the CLV 42x default host settings?

RS 422/485 at 9,600 bd, 8 data bits, no parity, 1 stop bit. p. 52

Which PC is needed for CLV Setup?

At least an 80486, 66 MHz, 16 MB RAM, CD-ROM drive and serial interface, with Windows 95/98, NT, 2000 or XP. p. 20

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1 Notes on this document13
    1. 1.1 Function13
    2. 1.2 Target audience13
    3. 1.3 Information content13
    4. 1.4 Symbols used14
  2. 2 Safety information15
    1. 2.1 Authorized personnel15
    2. 2.2 Intended use15
    3. 2.3 General safety instructions and protection measures16
    4. 2.4 Quick stop and quick restart18
    5. 2.5 Environmental information18
  3. 3 Product description19
    1. 3.1 Design19
    2. 3.2 Method of operation24
    3. 3.3 Indicators and operating elements25
  4. 4 Installation29
    1. 4.1 Overview of installation sequence29
    2. 4.2 Installation preparations29
    3. 4.3 Installing and adjusting the device35
    4. 4.4 Installing external components37
    5. 4.5 Removing the device40
  5. 5 Electrical connection41
    1. 5.1 Overview of the connection sequence41
    2. 5.2 Electrical connections and cables41
    3. 5.3 Connector pin assignment42
    4. 5.4 Preparations for electrical connection43
    5. 5.5 Making electrical connections44
  6. 6 Operation51
    1. 6.1 Overview of procedure for starting up the CLV51
    2. 6.2 Default settings51
    3. 6.3 Quick start53
    4. 6.4 Configuration (parameterizing)54
    5. 6.5 Operating modes and outputting the reading result64
    6. 6.6 CLV messages75
    7. 6.7 Switching off the CLV76
  7. 7 Maintenance77
    1. 7.1 Cleaning during operation77
    2. 7.2 Maintenance78
    3. 7.3 Disposal78
  8. 8 Troubleshooting79
27 more lines, from page 79 on
  1. 8.1 Overview of errors and malfunctions which could occur79
    1. 8.2 Monitoring errors and malfunctions79
    2. 8.3 Error messages80
    3. 8.4 Error status ST in read result of a bar code82
    4. 8.5 Troubleshooting83
    5. 8.6 SICK Support88
  2. 9 Technical data89
    1. 9.1 Data sheet CLV 420/421/422 bar code scanners (fixed focus)89
    2. 9.2 CLV dimensional drawings91
  3. 10 Appendix93
    1. 10.1 Overview93
    2. 10.2 Specification diagrams93
    3. 10.3 System messages98
    4. 10.4 Installation and operating instructions for the PC-based "CLV Setup" program99
    5. 10.5 Configuring the CLV with profile bar codes109
    6. 10.6 Configuring the CLV with command strings114
    7. 10.7 Calculating parameter values for setting the CLV116
    8. 10.8 Tables117
    9. 10.9 Special applications and procedures118
    10. 10.10 Replacing a CLV (copying the parameter set)127
    11. 10.11 Accessories130
    12. 10.12 Dimensional drawings of the accessories132
    13. 10.13 Supplementary documentation133
    14. 10.14 Glossary134
    15. 10.15 EC Declaration of Conformity140
    16. 10.16 Index141
    17. 10.17 Bar code samples145

From the PDF’s own bookmarks.

The whole text · 17 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12
  3. Pages 13 to 1813-18
  4. 3 Product description19-28
  5. 4 Installation29-40
  6. 5 Electrical connection41-50
  7. 6 Operation, pages 51 to 5951-59
  8. 6 Operation, pages 60 to 6860-68
  9. 6 Operation, pages 69 to 7669-76
  10. Pages 77 to 8877-88
  11. 9 Technical data89-92
  12. 10 Appendix, pages 93 to 10193-101
  13. 10 Appendix, pages 102 to 110102-110
  14. 10 Appendix, pages 111 to 119111-119
  15. 10 Appendix, pages 120 to 128120-128
  16. 10 Appendix, pages 129 to 137129-137
  17. 10 Appendix, pages 138 to 146138-146

The file

Revision and size

Revision8 009 981/O078/16-08-2004
PublisherSICK AG
Pages146
PDF3.7 MB
TextText from the PDF itself.

The first pages · 3 of 146

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 146
Page 2
Page 2of 146
Page 3
Page 3of 146

More documents · 2

For the same models