Page 69

Operation

Operating Instructions

Chapter 6

CLV 42x bar code scanner

6.5.4

Show CP-limits

In this mode, the CLV masks certain parts of the scan line so that any limit values defined for the active evaluation range of the scan line can be checked directly during parameterization. The restricted active evaluation range shortens the evaluation time for fast applications, for example, because the evaluation routine needs only take account of unmasked parts of the scan line. The range is restricted by entering appropriate values for MINIMUM CODE POSITION and MAXIMUM CODE POSITION in the CODE POSITION section on the READING CONFIGURATION tab or under DYNAMIC READING CONFIGURATION. The CLV does not output a reading result. SHOW CP-LIMITS can be called up via CLV 42X, DEVICE FUNCTIONS (interactively). The CLV masks the scan line alternately from the set value for CPmin and from the set value for CPmax. An example is shown in Fig. 6-11. The switchover is made continuously at intervals of one second. The part of the scan line that remains active for the reading procedure is the section between CPmin and CPmax. Example: Default setting: Evaluation set for the area from CPmin = 5 to CPmax = 95. The CLV masks the line from CPmin = 5 (short scan line) and from CPmax = 95 (long scan line). "Show CP-limits"

CPmax Active area

Scan line 2 CPmin Scan line 1

Fig. 6-7:

Appearance of scan line in the "Show CP-limits" mode

Proceed as follows to check the restricted evaluation range:

Note

8 009 981/O078/16-08-2004

1.

In the menu bar, choose SHOW CP-LIMITS under CLV 42X, DEVICE FUNCTIONS. The "Device Ready" LED is extinguished. The CLV cancels reading mode and masks the scan line alternately (as described above) from CPmin and CPmax.

2.

Check whether the bar code is located centrally in the area between the end of the shorter scan line (CPmin) and the end of the longer scan line (CPmax) or, if there are several bar codes, to determine whether the center of the field of all the codes is within range.

3.

If necessary, correct CPmin and CPmax accordingly. Perform a download to the CLV!

4.

In the menu bar, choose READING MODE under VIEW to exit the SHOW CP-LIMITS mode. The CLV returns to READING mode. The "Device Ready" LED lights up.

In the reading mode, the CLV does not actually mask the scan line visually, but instead takes the values specified for the restricted evaluation range into account when the data contents are decoded.

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-19

Page 70

Chapter 6

Operation

Operating Instructions CLV 42x bar code scanner

6.5.5

Displaying and editing operating data

This function enables statistical operating data, which the CLV maintains in the form of counters during the reading procedure, to be displayed and reset. The CLV does not output a reading result in this mode. 1.

Click in the toolbar. The CLV cancels reading mode. The "Device Ready" LED is extinguished. The OPERATING DATA dialog box appears (Fig. 6-8).

2.

After checking/resetting the desired counters, click "OK" to confirm any changes made. The CLV returns to reading mode. The "Device Ready" LED lights up.

Fig. 6-8:

6.5.6

CLV Setup: "Operating Data" dialog box

Reading diagnosis

Function of the terminal interface. In this mode, the CLV outputs the data contents of all the bar codes that were read – including those that, according to the evaluation criteria, were not read properly and were thus incorrect – together with the associated reading diagnosis data via the terminal interface. The number of bar codes output can, therefore, be higher than the number of those that were sent via the host interface in the reading result. In the default setting, this mode is selected for the terminal interface. Fig. 6-3, Page 6-15 shows the corresponding output format of the terminal interface. In the default setting, the CLV does not output any reading diagnosis data via the host interface. If the reading diagnosis is to remain inactive, this can be set via the AUXILIARY INTERFACE tab. 1.

In the AUXILIARY INTERFACE drop-down list, select READING DIAGNOSIS.

2.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.

3.

Confirm the dialog box by selecting the PERMANENT save option.

in the toolbar.

The terminal interface is now set to the "Reading Diagnosis" mode.

6-20

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 981/O078/16-08-2004

Page 71

Operating Instructions

Operation

Chapter 6

CLV 42x bar code scanner

6.5.7

Monitor host interface

Function of the terminal interface. In this mode, the CLV outputs the data traffic of its host interface via the terminal interface. Protocol driver handshakes and protocol-specific data, such as start and stop characters, are suppressed here (Table 6-6). Each data string is displayed on a separate line on the screen. Direction of data

Output format

Representation on screen

CLV receives from host

<STX> I data <CR> <LF> <ETX>

I data

CLV sends to host

<STX> O data <CR> <LF> <ETX>

O data

Table 6-6: "Monitor Host Interface" function

"Monitor Host Interface" is activated via the AUXILIARY INTERFACE tab. 1.

In the AUXILIARY INTERFACE drop-down list, choose MONITOR HOST INTERFACE.

2.

Perform a download to the CLV. To do so, click the MONITOR HOST INTERFACE option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLV temporarily. The terminal interface is then set to the "Monitor Host Interface" until the CLV is switched off again.

Displaying the data traffic of the host interface in the terminal emulator The data traffic of the host interface can be displayed in the terminal emulator of CLV Setup. Fig. 6-9, Page 6-22 shows an example of how the reading result can be output.

8 009 981/O078/16-08-2004

1.

Choose the serial interface as the external trigger source for the reading pulse (see Triggering the reading pulse via the terminal emulator, Page 6-16).

2.

Click in the toolbar. The terminal emulator window is then displayed. The CLV is in reading mode.

3.

Click the SW-TRIGGER ON button or press [F7]. The red scan line appears.

4.

Present the bar code sample from Fig. 6-1, Page 6-3.

5.

Click the SW-TRIGGER OFF button or press [F8]. CLV Setup outputs the reading result in the terminal emulator. Example: „0123412345“.

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-21

Page 72

Operation

Chapter 6

Operating Instructions CLV 42x bar code scanner

Fig. 6-9:

Note

CLV Setup: output of the reading result of the host interface in the terminal emulator at the beginning (in this case: O = Output)

Large amounts of data received at high speeds via the host interface and high data transfer rates may cause the flow of host interface traffic to no longer be completely displayed on the terminal interface (display "…"). This is caused by the slower data transfer speed of the terminal interface (9,600 bd). In the default setting, the CLV transmits the following data string via the host interface: •

Good Read: the data content of the bar code(s)

•

No Read: the NOREAD string

The “Header“, “Code Info/Separator“, “Splitter“ and “Terminator“ blocks are blank. Tip

6-22

The structure of the data output string of the host interface can be configured via the DATA STRINGS tab: •

Up to 10 elements, consisting of constants (control characters, letters, digits) and/or reading diagnosis data, can be entered in the “Header“, “Code Info/Separator“ and “Terminator“ blocks .

•

Up to 5 elements, consisting of constants (control characters, letters, digits), can be entered in the “Splitter“ block.

•

The position of the “CodeInfo/Separator“ block can be choosen before or after the Code.

1.

Select the DATA STRINGS tab.

2.

Click in the HEADER input field. The dialog window EDIT PARAMETER: TFH is displayed.

3.

Click the desired constants or placeholders for the reading diagnosis data. The selected elements appear in the text box at the top of the dialog window in the sequence in which they were selected.

4.

Confirm the dialog box with "OK".

5.

Repeat this procedure for the “Code Info/Separator“, “Splitter“ and “Terminator“ blocks.

6.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.

© SICK AG · Division Auto Ident · Germany · All rights reserved in the toolbar.

8 009 981/O078/16-08-2004

Page 73

Operating Instructions

Operation

Chapter 6

CLV 42x bar code scanner

7.

Confirm the dialog box by selecting the PERMANENT save option. The CLV outputs the selected elements in the data output string of the host interface with the next reading result.

6.5.8

Auxiliary input

Function of the terminal interface. In this mode, the CLV accepts a bar code entered at the terminal interface (via the keyboard or hand-held scanner with decoder). It sends the bar code to the host in a separate data string via its host interface. No reads can, therefore, be corrected by transmitting missing bar codes subsequently. Chapter 10.9.2 Auxiliary input via terminal interface, Page 10-31 describes this function and the associated procedure in greater detail. 6.5.9

Self-test

After the CLV has been switched on, it performs a self-test before it is initialized with the parameter set. The test can be called up explicitly at any time via CLV Setup. During the selftest, the CLV checks that its hardware components are functioning correctly. A final message via the terminal interface provides information on the test result. The CLV does not output a reading result during the test routine. 1.

Click in the toolbar. The terminal emulator window is then displayed. The CLV is in reading mode.

2.

Click SELF TEST under DEVICE MODE. The "Device Ready" LED is extinguished. The CLV cancels the reading mode and starts the test routine. After a few seconds, the CLV outputs the encoded test result in the form of a code number (Fig. 6-10).

3.

To return to the reading mode, activate READING MODE or close the terminal emulator. The CLV returns to reading mode. The "Device Ready" LED lights up.

Fig. 6-10:

8 009 981/O078/16-08-2004

CLV Setup: displaying the self-test result in the terminal emulator

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-23

Page 74

Chapter 6

Operation

Operating Instructions CLV 42x bar code scanner

The code number "15000" means that the self-test was completed successfully and that no faults were diagnosed. Chapter 8.3 Error messages, Page 8-2, lists the error key together with the associated corrective measures. 6.5.10

Performing device functions of the CLV in the dialog box

CLV Setup enables a number of CLV functions to be executed interactively. CLV Setup prompts the user to carry out specific actions and provides information on the progress of the function being executed. The following functions are available: •

AutoSetup

•

Match code Teach-in

•

Show CP-limits

•

Adjusting mode

•

Analyze scanner network (only if the CAN interface is used)

•

Activate factory defaults in device In the menu bar, select the desired function from CLV 42X, DEVICE FUNCTIONS. – or – Press the [F2] key. The DEVICE FUNCTIONS dialog box is then displayed. Select the desired function from the EXECUTE menu. CLV Setup starts the function and, where appropriate, prompts the user to carry out the necessary action.

Fig. 6-11 shows an example of the dialog box that appears after AutoSetup has been started.

Fig. 6-11:

6-24

CLV Setup: dialog box for AutoSetup execution

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 981/O078/16-08-2004

Page 75

Operating Instructions

Operation

Chapter 6

CLV 42x bar code scanner

6.6

CLV messages

The CLV outputs system messages, warnings and error messages in English in response to the actions carried out by the user. The messages are output in plain text via the terminal interface only. 6.6.1

Displaying messages

To display the messages on the PC in the CLV Setup user interface, proceed as follows: 1.

Click in the toolbar. The terminal emulator window is then displayed.

2.

In the TERMINAL MODE group, click the EXTENDED radio button.

The CLV then outputs messages in response to events that occur while the bar code is being read. The messages are only output in the extended mode of the terminal emulator! 6.6.2

System messages

System messages confirm that an action has been carried out successfully, e.g. changing the operating mode. No other actions are required here. Chapter 10.3 System messages, Page 10-6 explains the contents of the messages. 6.6.3

Warnings

Warnings indicate that it was not possible to perform an action or that the values set for the parameters can cause an error while the bar code is being read. Message

Meaning

Remedy

"Warning: Master Timeout"

Duration of the set master timeout is too short

Optimize the master timeout using the DEVICE CONFIGURATION tab in the user interface of CLV Setup. Download to the CLV! (see also technical information "Master/Slave with CLV Bar Code Scanners", no. 8 007 675, English version)

Table 6-7: Warnings

6.6.4

Error messages

Error messages indicate the following error sources: • a device defect

• incorrect parameter settings

• errors during data transfer to the host

Chapter 8.3 Error messages, Page 8-2 lists the messages in alphabetical order together with the associated corrective measures.

8 009 981/O078/16-08-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-25

Page 76

Chapter 6

Operation

Operating Instructions CLV 42x bar code scanner

6.7 1.

Switching off the CLV If the parameter set was modified in CLV Setup or was only stored temporarily in CLV via a download ("Temporary" option or via context menu (right mouse button)), the parameter set must be stored permanently in the CLV by choosing the PERMANENT storage option.

2.

Save parameter set as a "*.scl" configuration file in CLV Setup.

3.

Switch off the power supply of the CDB 420 or CDM 420 or pull the plug of the CLV from the connection module.

The last parameter set stored permanently in the CLV remains valid. We recommend that you print out the configuration file in order to archive the parameter set.

6-26

1.

Click in the toolbar. The PRINT FILE dialog box is then displayed.

2.

Enter a comment in the input field in order to assign the printout to the CLV. Confirm the dialog box with "OK". The PRINT dialog box for configuring the printer is then displayed.

3.

Edit the dialog box accordingly and confirm. CLV Setup prints out the current configuration file in the form of a table.

© SICK AG · Division Auto Ident · Germany · All rights reserved