Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 17

Operating Instructions: CLV 42x Bar Code Scanner, Standard line: 3 Product description

Pages 19 to 28 of 146, from Operating Instructions: CLV 42x Bar Code Scanner, Standard line

The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV420 and Sick CLV422

Page 19

Product description

Operating Instructions

Chapter 3

CLV 42x bar code scanner

3

Product description 3.1

Design

3.1.1

Scope of delivery

In the packaging the CLV is supplied with the following: • two polling reflectors for automatic reading pulse generation

• an information sheet (note on device) with terminal diagram and Quick Start instructions

• an additional set of Class 2 laser warning labels (self-adhesive) in German/US English and French/US English

Depending on the number of devices ordered, one or more copies of the following: •

CD ROM (no. 2 029 112) with – "CLV-Setup" program for WindowsTM and the "CLV-Setup Help" online help system (HTML files) – "CLV-Connect" PC software (HTML files showing terminal diagrams) – CLV 42x Operating Instructions in English and German as PDF edition as well as additional publications (connections module, other SICK bar code scanners) – freely available "Acrobat Reader" PC software for reading PDF files

Note

The latest versions of all the current publications/programs on the CD ROM can also be downloaded from www.sick.com. Depending on the number of copies ordered, the delivery includes (optional): •

CLV 42x Operating Instructions in English and/or German (printed edition)

Chapter 10.11 Accessories, Page 10-38 provides an overview of the available installation accessories, connection modules, cables and plug-in connections and sensors for reading pulse generation. 3.1.2

Variants

The CLV is available in the following variants: Type

Order no.

Scan procedure

CLV 420-0010

1 022 031

Line scanner, standard range

CLV 420-1010

1 022 032

Raster scanner, standard range

CLV 420-2010

1 022 033

Line scanner with 105° angle attachment, standard range

CLV 420-3010

1 022 034

Raster scanner with 105° angle attachment, standard range

CLV 421-0010

1 022 547

Line scanner, long range

CLV 421-1010

1 022 616

Raster scanner, long range

CLV 421-2010

1 022 617

Line scanner with 105° angle attachment, long range

CLV 421-3010

1 022 618

Raster scanner with 105° angle attachment, long range

CLV 422-0010

1 022 548

Line scanner, high density

CLV 422-1010

1 022 619

Raster scanner, high density

CLV 422-2010

1 022 620

Line scanner with 105° angle attachment, high density

CLV 422-3010

1 022 621

Raster scanner with 105° angle attachment, high density

Table 3-1: Variants of the CLV 42x

8 009 981/O078/16-08-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-1

Page 20

Product description

Chapter 3

Operating Instructions CLV 42x bar code scanner

3.1.3

System requirements

The following are required to start up and operate the CLV 42x: 1.

A SICK connection module to provide the power supply and connect the data and function interfaces. Available types: – CDB 420-001 (no. 1 023 885) for 10 to 30 V DC, enclosure rating max. IP 65 – CDM 420-0001 (no. 1 025 362) for 10 to 30 V DC, enclosure rating max. IP 65

– or – Alternatively, a non-SICK power supply unit with a voltage output of 10 to 30 V DC (functional extra-low voltage pursuant to IEC 364-4-41) and at least 4 W power output. Cable no. 6 010 137 with 15-pin D Sub HD connector and one open end for connecting the CLV to the external power pack. Note

The CLV 42x is UL certificated when a class 2 power supply according to UL 1310 is used. 2.

The following operating voltages/power outputs – CDB 420-001: 10 to 30 V DC, pursuant to IEC 364-4-41, at least 4 W – CDM 420-0001: 10 to 30 V DC, pursuant to IEC 364-4-41, at least 4 W – If the following modules are additionally built-in in the CDB 420 module: CMC 400 Connection Module Cloning: 10 to 30 V DC, additionally 0.5 W – If the following modules are additionally built-in in the CDM 420 module: CMC 400 Connection Module Cloning: 10 to 30 V DC, additionally 0.5 W CMD 400 Connection Module Display: 18 to 30 V DC, additionally 1 W CMF 400 Connection Module Fieldbus: 18 to 30 V DC, additionally 2 W

3.

With external clock pulse (start/stop of reading interval) supply via the “Sensor 1“ switching input: a suitable reading pulse sensor for signaling the presence of an object with a bar code, e. g. a photoelectric reflex switch.

4.

With optional external clock pulse (stop of reading interval) supply via the “Sensor 2“ switching input: a suitable reading pulse sensor for signaling the end of reading intervall, e.g. a photoelectric reflex switch.

5.

To separate bar codes with the same name (same code type, identical data content) using the "Compare Code Position" function: a suitable incremental encoder.

6.

A higher-level computer (host) with a data interface of type RS 422/485 or RS 232.

7.

A PC (at least 80486, 66 MHz, 16 MB RAM, CD-ROM drive, serial interface, mouse (recommended) with Windows 95TM/98TM, Windows NTTM, Windows 2000TM or Windows XPTM.

8.

A 3-core RS 232 data cable (null modem cable) with two 9-pin D Sub sockets for connecting the PC to the terminal interface of the CLV in the connection module CDB 420 or CDM 420, e. g. no. 2 014 054. Pin 2 (RxD) and Pin 3 (TxD) are crossed.

9.

To use the online help system CLV Setup Help, an HTML browser is required, e. g. Internet ExplorerTM.

10. To connect the CLV to Profibus DP, DeviceNet, and Ethernet: the corresponding CMF 400 Connection Module Fieldbus (Operating instructions see Chapter 10.13 Supplementary documentation, Page 10-41). 11. For connection of the CLV to the CAN bus: the operating instructions "Application of the the CAN interface" (no. 8 009 180, English)

3-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 981/O078/16-08-2004

Page 21

Operating Instructions

Product description

Chapter 3

CLV 42x bar code scanner

3.1.4

Product features and functions (overview)

High-performance laser scanner: •

Fixed focus

•

Line scanner, variant: raster scanner

•

Front reading window, variant: side reading window

•

Reading range 60 to 740 mm (2.36 to 29.1 in), type dependent

•

Resolution 0.15 to 1.0 mm (5.9 to 39.4 mil), type dependent

•

Scanning/decoding frequency 400 to 1200 Hz

•

Function to adjust on the code print quality, also via reading configuration

•

Variable active evaluation range of the scan line

Safety and user-friendly features: •

Robust, compact metal housing, max. IP 65, CE certification

•

UL certificated when a class 2 power supply according to UL 1310 is used (valid only with corresponding product marking on the nameplate).

•

Laser class 2, laser diode switches off if reading interval is active for too long and if the output power is exceeded

•

Automatic self-test on startup. Can also be triggered at any time

•

Diagnosis tools for installing and monitoring the system

•

Parameterized output of reading diagnosis data in the read result

•

Operating data query, and error messages

•

Test string function for signaling readiness for operation

•

Future proof thanks to firmware update via serial data interface (flash PROM)

•

Low power consumption, other voltage range

Easy operation/configuration: •

With "CLV-Setup" PC software for Windows (online), integrated Assistant and Help system

•

With Profile bar codes (offline)

•

Alternatively with simple command strings, also for use with special devices

•

Four status LEDs

•

Beeper to confirm device functions or operating steps (can be switches off)

Operating modes:

8 009 981/O078/16-08-2004

•

Reading mode

•

Percentage evaluation - for assessing the quality of the reads

•

AutoSetup

•

Special functions for system installation

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-3

Page 22

Chapter 3

Product description

Operating Instructions CLV 42x bar code scanner

Bar code evaluation: •

All standard bar code types

•

Max. 10 codes per reading pulse (max. 100 characters), max. 3 per scan

•

Separation of identical bar codes of the same code type

•

Code comparison (max. 2 matchcodes), can also be used as filter for the reading result

•

Sort sequences: code position, FIFO, LIFO, code length list

•

Manipulation of the data output string via filter or format mask

Reading pulse: •

External reading pulse, via switching input or serial interface

•

Free running with timeout

•

Continuous Read

•

Reflector Polling for generating the reading gate automatically

Electrical interfaces: •

Serial host interface (RS 232, RS 422/485) with variable transfer rate, protocol and telegram structure

•

Serial terminal interface (RS 232) as auxiliary data interface with special diagnosis functions

•

CAN interface for integration in the SICK CAN scanner network or a CANopen network

•

2 switching inputs for external reading pulse and special function (e.g. teach-in of match code)

•

2 switching outputs for signaling defined events in reading mode

Connections:

3-4

•

All interfaces are connected via a cable with one 15-pin D Sub HD plug

•

CDB 420 or CDM 420 Connection Module for connection to host (stand-alone) and for integration in SICK CAN scanner network

•

CMF 400 Connection Module Fieldbus in the CDM 420 Connection Module for connection to field bus systems

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 981/O078/16-08-2004

Page 23

Product description

Operating Instructions

Chapter 3

CLV 42x bar code scanner

3.1.5

View of line/raster scanner devices

2 1

3 7

6

4

5

Legend:

8

1 D Sub HD plug, 15-pin 2 Tapped blind holes M4, 6 mm (0.24 in) deep

3 Reading window 4 Laser warning labels 5 Connection cable 6 Sound opening of the beeper (hidden)

7 LEDs (status indicators) 8 integrated angle attachment, Front reading window

Fig. 3-1:

Side reading window with 105° light reflection

CLV42x line/raster scanner with/without 105° angle attachment

8 009 981/O078/16-08-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-5

Page 24

Chapter 3

Product description

Operating Instructions CLV 42x bar code scanner

3.2

Method of operation

The CLV first scans the bar code with a scan line and then decodes it. The CLV forwards the data via the serial host interface (main data interface) to a host/PC for further processing. An overview of the CLV functions is provided in Fig. 3-2. CLV 42x

PC Operation Parameterizing, etc.

Photoelectric switch Reading pulse

HOST Further processing of the reading result Status indicator e. g. Good Read e. g. No Read

Signal Teach-in match code 1 Path increment End of reading interval DC 10 to 30 V

Fig. 3-2:

Block diagram: CLV functions

The tried and tested standard decoder of the CLV series is available for decoding. The CLV derives useful diagnosis data from the reading process and transfers it to the host. It also records operating data that can be interrogated at any time. The quality of the read can be checked in "Percentage Evaluation" mode. To start a reading process when an object is located in the reading field, the CLV requires a suitable trigger. This opens a time window ("reading interval") in the CLV for the reading procedure. In the default setting, this trigger is supplied by an external reading pulse sensor. Alternative trigger sources include reflector polling, free-running mode or a command via the host interface. The current operating status is indicated by four LEDs. A beeper indicates the status of the reading result. In the default setting, the "Good Read" function is selected for this. If the trigger is supplied externally by a sensor, the "Sensor 1" switching input signals the start of the reading procedure to the CLV. The "Sensor 2" switching input can be used to teach in a match code. The "Result 1" and "Result 2" switching outputs can be assigned various functions and trigger external devices, such as a PLC. The CLV is operated and configured via the serial terminal interface (auxiliary interface) using the "CLV Setup" software or via the host/terminal interface and command strings. System messages, warnings and error messages help you with configuration and with locating the source of errors during startup and in reading mode.

3-6

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 981/O078/16-08-2004

Page 25

Operating Instructions

Product description

Chapter 3

CLV 42x bar code scanner

3.2.1

Scan procedure variants

Line scanner Generates a scan line. Due to the V-principle of beam deflection, the reading field height (for evaluating the useful length of the scan line) is dependent on the reading distance. Raster scanner Generates 8 parallel scan lines that are offset by the same distance. Due to the V-principle of beam deflection, the reading field height (for evaluating the useful length of the scan lines) is dependent on the reading distance. Raster height of the scan line field: 15 mm (0.59 in) at a reading distance of 200 mm (7.88 in) (front reading window).

3.3

Indicators and operating elements

3.3.1

Operating elements

The CLV is operated and configured via the terminal interface (auxiliary interface) using the "CLV Setup" program or using command strings sent via the host interface/terminal interface. A variety of parameterizing options allow you to adapt the device to a wide range of applications. The following can be defined (among others): • the configuration of the code types to be read

• the reading, evaluation and output characteristics

• the communication parameters of the host interface

• the structure of the data output string for "good read" and "no read" on the host interface

• the function of the terminal interface

Chapter 10.4 Installation and operating instructions for the PC-based "CLV Setup" program, Page 10-7 describes the procedure for installing the "CLV Setup" program and how to operate the user interface. Configuration (parameterizing) is explained in Chapter 6.4 Configuration (parameterizing), Page 6-4. 3.3.2

Function of the LED indicators

Four LEDs indicate the operating status, activity of the laser diode, output of the reading result, and data transfer on the host interface. The LED indicators (Fig. 3-3) are located on the rear of the device. Table 3-2 shows the meaning of the LED indicators in the different operating modes/functions.

Fig. 3-3:

8 009 981/O078/16-08-2004

LED indicators

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-7

Page 26

Product description

Chapter 3

Operating Instructions CLV 42x bar code scanner

Operating mode

LED

Indication

Function

Start

Device Ready orange

• lights up after power-up if the self-test was successful and the wait time for reading the profile bar codes has expired

Laser On orange

• lights up while the laser diode for reading the profile bar codes is active

Device Ready orange

• illuminates constantly

Reading mode

• extinguishes with new operating mode/function orange

Laser On

• lights up if reading diode active (The laser diode is activated/deactivated by reading pulse) • lights up constantly in the pulse modes "free running" and “Continuous Read“, as the laser diode is always active • lights up with every 20th scan in the "reflector polling" pulse mode. The scan line is faintly visible.

orange

Result

LED is connected to the "Result 2" switching output. It indicates the selected result status for the set pulse duration of the output. • lights up after a good read (default setting: "good read") • lights up (match code comparison active) if the read bar code matches the predefined match code(s) and the corresponding result status output is selected for the "Result 2" output

Percentage evaluation

Data orange

• flickers while the CLV transfers data to the host on the host interface

Laser On orange

• lights up constantly (Free Running mode)

Result orange

Behavior depends on the reading quality: • extinguishes if reading rate < 30 % • blinks twice a second if reading rate 30 % to 70 % • blinks five times a second if reading rate 70 % to 90 % • lights up constantly if reading rate > 90 %

Profile programming

Laser On orange

• lights up while the profile bar codes are being read (Free Running mode)

AutoSetup

Laser On orange

• lights up while the application-specific bar codes are being read (Free Running mode)

Adjusting mode

Laser On orange

• lights up constantly (Free Running mode)

Show CP-limits

Laser On orange

• blinks bright/dark alternately, in the frequency with which the scan line is partially masked out

Table 3-2: Meaning of the LED indicators

3-8

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 981/O078/16-08-2004

Page 27

Product description

Operating Instructions

Chapter 3

CLV 42x bar code scanner

3.3.3

Function of the beeper

The beeper uses different tone sequences and lengths (Table 3-3) to signal whether functions have been executed successfully and whether any malfunctions have occurred. For information on troubleshooting, see Chapter 8.5 Troubleshooting, Page 8-5. In the default setting, the beeper indicates the event status "Good Read" by means of a "Low" (quiet) beep. It is assumed in these operating instructions, that the beeper is operated with the default setting in Reading mode. The sound opening of the beeper is located on the rear, narrow side of the device and below the LED labeling. Operating mode

Tone sequence

Beeper function

Start

Beep

• signals that the self-test after power-up was successful

Reading mode

Beep Beep

• confirms that the device has assumed Reading mode after power up and after the wait time of 5 s for reading the profile bar codes has elapsed

Beep

• confirms a successful read (good read; default setting) and the reading result output

Beep

• confirms successful read of profile bar code for start/end of AutoSetup

Beep Beep

• confirms successful read of application-specific bar code and start of reading mode

Beep (long tone)

• signals that the application-specific bar code was not read

Beep

• confirms successful read of profile bar code

Beep Beep

• confirms start of reading mode 10 s after last profile bar code was read

Beep Beep Beep

• signals that the laser diode has been deactivated after the laser timeout of 10 min (default setting) was exceeded in Reading mode. The reading pulse is still active.

Profile programming Start AutoSetup

Profile programming

Exceeding the laser timeout

Table 3-3: Beeper function

Tip

The behavior of the beeper in reading mode can be changed on the DEVICE CONFIGURATION tab in the CLV Setup program. Volume: Click the required field in the BEEPER VOLUME section. Output function for the result status 1.

Click the RESULT OUTPUT PARAMETERS button in the RESULT OUTPUT section. The RESULT OUTPUT PARAMETERS dialog box is displayed.

2.

Click the BEEPER list field in the RESULT FUNCTIONS section. The list containing the available result status functions appears.

3.

Click the required function and confirm with "OK".

4.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.

5.

Confirm the dialog box by selecting the PERMANENT save option.

in the toolbar.

The CLV operates the beeper with the values selected for the result status indication and volume.

8 009 981/O078/16-08-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-9

Page 28

Product description

Chapter 3

Operating Instructions CLV 42x bar code scanner

Notes

3-10

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 981/O078/16-08-2004