Page 21
Installing PC-Resident Starnode Board
FIGURE 2–3. Address and Jumper Position Examples
2 Installation
Hex 200 (Game I/O)
Hex 300 (Prototype)
Hex 3A0 (Bisync)
Hex 340 (Undocumented)
Hex 360 (Undocumented)
Set the jumpers in the Up or Down positions to configure the address for your board. In interpreting the jumper settings on JH4, position the interface board with the gold fingers away from you. The LSB should be in the top right of the jumper header. If none of the addresses in Figure 2–3 are available, consult the technical reference manual for your PC to determine which I/O port addresses can be used. To determine the jumper positions for your address, convert your hexadecimal board address into 16 binary digits. For example, if your hexadecimal address is 0300, the 16-bit representation is: 0000 0011 0000 0000 Only these 7 bits are used Drop the left most four digits and the right-most five digits as shown in Figure 2–4.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
2-5
Page 22
Chapter
2
Installation
FIGURE 2–4. Converting Hexadecimal Address into Jumper Settings
0
3
0
0
8 4 2 1
8 4 2 1
8 4 2 1
8 4 2 1
0011
000
16-bit address
Jumpers on JH4
These bits are shaded and are assumed by software. The remaining seven bits are translated into jumper settings. Up for a binary 1, Down for a binary 0. Figure 2–4 shows hexadecimal address of 300 (default) translated into jumper settings on JH4.
2-6
9.
Holding the Starnode interface board by the upper edges or corners, press it firmly down into the slot that you selected. The Starnode PC interface board may not fit perfectly into the PC's slot. Verify that the copper fingers along the bottom edge of the board make good contact with the socket connectors.
10.
Secure the screw that holds the connector plate. This will ensure that the interface board does not move.
11.
Plug the blue Starnode interface cable, 9-pin male connector into the female socket on the Starnode board. Tighten the screws on the connector so that the connector is firmly mated with the Starnode board.
12.
Replace the cover on your PC.
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 23
T-Tap Boxes
The standard T-Tap connector box is used to connect a compatible network device to a branch circuit as shown in Figure 2–5. It may also be used as a branch circuit cable extender.
2
FIGURE 2–5. T-Tap Connector
Installation
T-Tap Boxes
Insert White leads in W terminals. Insert Blue leads in B terminals. End terminals reserved for resistor.
Three connections are made to each T-tap box. However, the T-tap box at the end of each branch circuit has two connections. To properly terminate the branch circuit, it is necessary to install a terminating resistor in the last T-tap box. This factory supplied, 75-ohm, 1/2-Watt resistor is installed across the blue and white bus strips as shown in Figure 2–6.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
2-7
Page 24
Chapter
2
Installation
FIGURE 2–6. T-Tap with Terminating Resistor Installed
W
B W B W B W B
B W B W B W
Terminating Resistor For convenience, install before Branch Cable leads.
To clearly identify T-Tap boxes containing a terminating resistor, a yellow sticker is provided with each T-Tap box. Please remember to apply this sticker only to TTap boxes that contain terminating resistors. Note: If your network is expanded in the future, you may need to remove the terminating resistor from its original T-Tap box and re-install it in another T-Tap box. As your network changes, remember to leave a T label affixed only to those T-Tap boxes that contain a terminating resistor. SICK Auto Ident, Inc. should verify your network after each major change.
Network Cabling The shielded, twisted pair Starnode 20 AWG cabling meets RS-485 standards, supports high baud rates, and offers immunity to most sources of electrical noise. The shielding also protects the conductors from the effects of electromagnetic interference.
2-8
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 25
Electrical current originates at the Starnode controller or Repeater, travels down one wire and back on the other. Only one device in the network can be sending data at any instant in time. The Starnode controller uses a polling technique to recognize one device at a time for data transmission to the host.
2
The signal strength in an RS-485 line is a function of many factors. First, the power of the sending device's transmitter chip can affect signal strength. Also, the number of drops (devices) in the network can affect the circuit: the more drops, the weaker the current on the line. Finally, although all Starnode cabling is 78 ohm (low impedance) cabling, distance can have a major impact on Starnode communications. For example, the greater the cable-distance between the receiver and sender, the weaker the signal.
Installation
Cabling Types
After the Starnode network has been installed, an ohmmeter should be used to verify that there are no connections in the network with high resistance values. Such points could cause echoes on the line, so the elimination of high-resistance connections is essential. Signals pass over a Starnode network cable at the speed of light. An echo is a signal that bounces back from the end of an interface cable or a poor connection; the time lag between the original signal and the echo causes interference on the network line. The longer the cable involved, the greater the time lags between the signal and echo and the greater the interference. All Starnode network cabling is standard twin-ax, 78-ohm cable, equivalent to Belden 9463, Alpha 9815, and Manhattan 4227. The dimensions and stiffness of both cable and insulating material are critical to proper electrical connections when using a T-Tap box. Fiber Optic cable can also be ordered if using a Starnode Optic Link.
Cabling Types Two types of cabling can be used to connect the devices in a Starnode network. •
Standard, 78-Ohm Starnode cabling
•
Plenum cable for locations where cabling must be run in the plenum (false ceiling or air chamber). Check the state and local fire codes that apply for your site. The plenum cable offered by SICK Auto Ident, Inc. has a red external shield of Teflon™ or other suitable material. Most state electrical codes require that ordinary cable installed in the plenum be installed in conduit. An SICK Auto Ident, Inc. plenum-rated cable may allow Starnode
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
2-9
Page 26
Chapter
2
Installation network cabling to run through the plenum without the use of costly conduit tubing. Both cables can be ordered in varying lengths, using SICK Auto Ident, Inc. part numbers as shown in Table 2–1. TABLE 2–1. Cable Part Numbers
Part Number
Description
A1-70156-1
Standard Starnode cable, 25-foot length, terminated at one end with a ninepin, D-type connector. A 25-foot segment is required for each T-tap installed on the network.
966-0082-1-0100
Standard Starnode cable, 100-foot length (unterminated)
966-0082-1-0500
Standard Starnode cable, 500-foot length (unterminated)
966-0082-1-1000
Standard Starnode cable, 1000-foot length (unterminated)
A1-70181-2
Plenum stub cable, 15-foot length (nine-pin, D-type connector)
966-0103-0500
Plenum cable, 500-foot length (unterminated)
966-0103-1000
Plenum cable, 1000-foot length (unterminated)
Note: Do not substitute other cabling for those specified. On-site fabrication of cables is NOT recommended. Use of unshielded cabling is not supported. Also, using a single cable for multiple purposes other than Starnode is not recommended. The first branch circuit, connected to the Starnode controller, must always begin with an interface cable and T-tap box, used as a cable splicer. Normally, this TTap box will have only two cables attached to it. The short (25 or 15-foot) cables with connectors are sometimes referred to as stub cables. These cables are used to connect to a branch cable. The standard Starnode cable consists of the following parts and is shown in Figure 2–7. •
2-10
The blue conductor
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 27
Barcode Scanners
•
The white conductor
•
Two cable strengtheners/fillers
•
The shield conductor
2 Installation
FIGURE 2–7. Network Cable Construction
Blue Conductor Shield Conductor
Outer Insulation (blue)
Plastic Filler Strips
White Conductor
The blue conductor is a wire with blue insulating material. The white conductor is a wire with opaque insulating material. The cable strengtheners/fillers are usually white or blue and of a smaller diameter than the white conductor. The surrounding woven web of silver wire is the shield conductor. Most plenum-rated cabling sold by SICK Auto Ident, Inc. has a red exterior casing of Teflon™ or other suitable material. The conductors in this cable are black and white instead of blue and white as in the network cabling. For consistency, ensure that you use the same plenum-rated cabling throughout your network. Mixing cabling of different colors may cause confusion.
Barcode Scanners A number of programmable Starnode terminals can be used in conjunction with the Starnode network. All read barcode data by an attached light pen or laser gun. Alternatively, fixed-station laser scanner/decoders can be used. These fixed position scanners illuminate barcodes by projecting a laser spot across a moving conveyor carrying barcode-labeled packages or items.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
2-11
Page 28
Chapter
2
Installation
Regardless of which Starnode device is selected, all SICK Auto Ident, Inc. scanners can independently identify and decode a barcode symbology. Thus, only decoded barcode data is sent out to the controller. The scanner or terminal, not the controller, performs the task of decoding. Refer to the appropriate Starnode device operator's manual for more information.
Testing the Network The utility Starndem under Windows 95 may be used to test the network as described in Chapter 5, “Using Starndem”. After you have supplied the network I/O base address when prompted, the software will attempt to initialize the controller. The software will begin polling the Starnode controller for new messages and displaying these to the screen. If you are using Starnode data collection terminals, put the terminals in Lan Access Mode. Barcode scanners automatically enter Lan Access mode when they are booted. Scan data from one or more of the barcode devices to insure that the network is functional. If any errors occur during this procedure the software will stop and display the appropriate error message. Should errors occur, refer to Chapter 10, “Maintenance & Troubleshooting”. If you will be using the controller from a DOS environment, the network may be tested by installing the DOS driver and then using the Starn utility. Refer to “Using STARN Program” on page 6-5. Enter Starn init to initialize the network. Scan labels from any barcode scanning device that is currently in Lan Access mode. Run Starn recv to retrieve and display the barcode data.
2-12
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 29
3 Starnode Accessories
3
Starnode Accessories
CHAPTER 3
This chapter describes software and hardware accessories for use with the Starnode Controller.
Software Products SICK Auto Ident, Inc. offers a number of software products that may be of use when developing Starnode based systems, including drivers for additional host platforms, development tools such as OLE Servers and ActiveX controls, data collection applications, and applications for configuring, monitoring, and setting up your Starnode based barcode scanners. •
Starnode Driver for Windows NT and Windows 2000
•
Starnode Driver for SCO UNIX
•
Starnode Driver for OS/2
These products provide the basic functionality of the Starnode Developers disk for the corresponding host platform. The Starnode OLE Server for Windows NT requires the Starnode Windows NT driver. •
Starnode OLE Server for 95 and Windows 98
•
Starnode OLE Server for Windows NT and Windows 2000
The Starnode OLE Servers contains the utility software Multidem for controlling the Starnode network and collecting data to text files. The utility DbConvert is also provided, for uploading the data to an ODBC compatible database / server.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
3-1
Page 30
Chapter
3
Starnode Accessories
An OLE Automation server is provided, which simplifies application development. The OLE Server allows one or more applications to share send and receive access to the Starnode controller, for example to run Multidem to log all Starnode data to a text file as an audit trail while a separate custom process control application processes this data. Data sent by the applications to the barcode devices will be buffered in a queue for a configured period of time until the destination device is ready to accept another message. COM Events may be used for notification that new data has been received, or that a queued message has been sent. For environments that do not support OLE Automation servers but do support ActiveX controls, a control has been provided that supports all of the OLE servers’ capabilities. The balance of the software products described support the Starnode OLE Server, as well as the Serial OLE Server and TCP/IP Server. Since the OLE Servers provide shared device access, one or all of these products may be used with the barcode scanning devices at the same time. Any functionality not provided by these applications could be implemented by developing a custom application using the Starnode OLE Server, so that the custom application may also be used at the same time as the other application(s). •
CiMenu32 (requires Starnode OLE Server) CiMenu32 is a user-friendly Windows utility for setting up your Starnode compatible barcode devices. It detects which devices are currently connected and displays their current setup for modification. On-screen help for each parameter displays what the parameter is used for and what effect each available setting will have on the device. After modifying the device parameters the new configuration may be downloaded to the device, downloaded to a new device, and saved or restored using a text file.
•
DataManager+ 32 (requires Starnode OLE Server) DataManager+ 32 is a data collection application, which acts as a server to provide the barcode scanners with access to host database systems / servers. It supports approximately 30 different types of requests that barcode scanners may make including requests to execute SQL statements and procedures, transfer text files, log errors, and send messages to other devices on Starnode, serially, or through TCP/IP.
•
CiView (requires Starnode OLE Server) CiView may be used to monitor barcode scanning device status and performance over a period of time. A summary display shows which devices
3-2
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002