Page 11
Return-to-Factory Instructions Should your Starnode Controller system fail to operate correctly, verify the following: •
Confirm that it has been properly configured with the proper setup parameters, as ordered.
•
Inspect and verify all cable connections.
If a problem persists, contact your sales representative or SICK Auto Ident, Inc. Customer Service by calling the numbers provided in “SICK Auto Ident, Inc. Customer Service Policy”. Please call SICK Auto Ident, Inc. at 1-888-264-4641 to return a Starnode Controller for repair. Request the Return Authorization (R.A.) Department. Please be prepared to furnish the following information: •
Company name, address, and telephone number
•
Contact name
•
Return address (if different) and other pertinent shipping information
•
Catalog number and serial number
•
Description of the problem
•
Purchase order and other invoicing information relative to the repair
SICK Auto Ident, Inc. will provide you an R.A. number. Please include this R.A. number on the shipping label and any correspondence concerning the return. Please include several sample barcode labels, a listing of setup parameters and a detailed description of the problem. Repair or upgrade estimates shall be furnished upon request. Upon receiving a defective product with a valid Return Authorization number, SICK Auto Ident, Inc. will attempt to return the repaired or replacement equipment on a best-effort basis within five working days. You may have a different support plan specifying other terms. For critical applications, SICK Auto Ident, Inc. recommends you keep a spare controller on hand for immediate replacement. Alternatively, you can select a support plan that specifies a quick response time or a controller swap.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual xi
Page 12
Preface
SICK Auto Ident, Inc. shall pay surface transportation charges for the return shipment if the address is within the 48 contiguous states or the District of Columbia. Customers outside this area shall pay shipping costs, customs clearance, and any other related charges. Your controller will be returned after inspection and repair. However, upon return, the controller may require re-configuration to the setup parameter values you were using.
Product Warranty SICK Auto Ident, Inc. guarantees that its products are free from defects in materials or workmanship (under proper and normal use and maintenance) in accordance with SICK Auto Ident, Inc.’s operating instructions for a period of one year from the shipping date. This warranty shall be null and void if equipment is modified, if it is improperly installed or used, if it is damaged by accident or neglect, or if components are improperly installed or replaced by the buyer. Under no circumstances shall SICK Auto Ident, Inc. be liable to the buyer or any other party for lost profits, diminution of good will, or other special or consequential damages whatsoever. The warranty appearing here supersedes all other warranties, express or implied, statutory or otherwise, including any implied warranty of merchantability or fitness for a particular purpose.
xii
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 13
1 Introduction
1 Introduction
CHAPTER 1
Introduction Starnode is a sophisticated barcode data collection network that allows two-way communication with a multi-dropped network of compatible fixed-station laser scanner/decoders or barcode data collection terminals. Employing a flexible tree/bus topology to facilitate network cabling and circuit expansion, Starnode provides a practical alternative to more costly local area networks (LANs) for a wide variety of factory automatic identification applications. The Starnode PC Data Collection Network Operator's Manual is written for anyone who must install, use, or maintain a Starnode network from a PC equipped with a Starnode PC interface board.
Controllers The network controller coordinates communication activity on the Starnode network cable. The processor inside the controller polls groups of Starnode devices, gradually narrowing the poll to a specific Starnode device that has a pending message. The controller then passes the message to the host. When the host sends a message to a Starnode device, the controller verifies that the Starnode device addressed did, in fact, receive its message. Polling is performed independently of the host, so the host is freed for other processing activities. The controller can also be used to download customized Terminal Application Level Language (TALL) or C programs as Starnode devices are powered up.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
1-1
Page 14
Chapter
1
Introduction
SICK Auto Ident, Inc. offers three types of controllers for coordinating communication activity in a Starnode network: •
The PC-resident Starnode interface board
•
The Starnode Asynchronous Controller (AC)/ CICALP interface
•
The Starnode Asynchronous Controller (AC)/ MUX interface
All three controllers can contain two kinds of memory, Read Only Memory (ROM), which controls the operation of the controller itself, and Random Access Memory (RAM), which contains the user programs to be downloaded to Starnode devices, and buffered messages from Starnode devices. This manual describes the operation of a network via the Starnode PC interface board. While other controllers, repeaters, and accessories are briefly described, please refer to the appropriate operating manuals. Refer to the Starnode Site Planning and Installation Guide for information on installing Starnode cabling and hardware. All three controllers can communicate with other Starnode devices on RS-485 lines at a baud rate of 125K bits per second. The following paragraphs describe each of these controllers.
Starnode PC Interface Board The Starnode PC Interface Board can be installed in any IBM PC with an ISA slot or compatible PC with an available ISA slot. With the board installed the PC can continue to run resident programs or service other devices without interference from Starnode. The Interface Board with a front view depicting the location and configuration of the external connector is shown in Figure 1–1.
1-2
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 15
FIGURE 1–1. Starnode PC Interface Board - Front View
The Starnode PC board is available in four versions. All versions support a network of up to 4,095 Starnode addresses. All versions have a 16K character buffer capability to hold Starnode device-initiated messages. The Starnode PC board may be reconfigured through software to reallocate a portion of the program download memory for use in buffering additional receive messages. The versions are in the amount of download table space available, shown in Table 1–1. TABLE 1–1. Downloadable Table Space
Version
Table Space
A1-66965-1
256K
A1-66965-2
512K
A1-66965-3
1024K
A1-66965-4
2048K
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
1 Introduction
Starnode PC Interface Board
1-3
Page 16
Chapter
1
Introduction
Starnode Asynchronous Controller (AC)/CICALP The Starnode Asynchronous Controller (AC), CICALP interface (A1-66676-1) is a stand-alone unit that coordinates a network of up to 1,023 Starnode addresses. These would consist of Starnode-compatible fixed-station laser scanner/decoders or Starnode bar code data collection terminals. The Starnode AC/CICALP has a 256K-byte file memory. Software written for the host in the versatile C programming language allows the host and Starnode AC/CICALP to communicate via the SICK Auto Ident, Inc. Asynchronous Link Protocol (CICALP). The Starnode AC/CICALP uses 128K bytes of the file memory for storing a download table; the remaining 128K bytes are used for spooling up to 900 incoming, Starnode device-initiated messages. The programming and operation of the Starnode AC/CICALP is beyond the scope of this manual. Refer to the Starnode AC/CICALP Operator's Manual for more information.
Starnode Asynchronous Controller (AC)/MUX The Starnode Asynchronous Controller (AC), MUX interface allows up to 1,023 Starnode addresses, consisting of Starnode devices multiplexed on a single host communications link. The Starnode AC/MUX looks identical to the Starnode AC/CICALP, but is available in two models. The Starnode AC/MUX (A1-66676-2) has a 256K-byte file memory module that allows the unit to spool messages from Starnode devices. A 128K-byte download table is maintained, while the remaining 128K bytes of file memory are reserved for spooling up to 900 incoming, Starnode device-initiated messages. The Starnode AC/MUX (A1-66676-3) has no file memory; therefore, it has no download table and it cannot spool Starnode device-initiated messages. However, it is identical in all other respects to the (A1-66676-2). The programming and operation of the Starnode AC/MUX is beyond the scope of this manual. Refer to the Starnode AC/MUX Operator's Manual for more information.
1-4
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 17
2 Installation
2 Installation
CHAPTER 2
This chapter provides instructions for installing the Starnode controller, software provided with your controller, network cabling, and T-Taps required to create the Starnode system. Refer to Chapter 3, “Starnode Accessories” for optional software and hardware for use with Starnode.
Installation Overview Building a Starnode system requires a PC equipped with the Starnode controller, a Starnode software driver and/or application, network cabling, T-Tap boxes for connecting from the Starnode controller to scanning devices, and barcode scanning devices as shown in Figure 2–1.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
2-1
Page 18
Chapter
2
Installation
FIGURE 2–1. Starnode System - Typical Configuration
Starnode PC
Starnode cables
T-Taps
Barcode Scanners
The software application uses Starnode interface routines within the appropriate driver to initialize the controller to begin polling barcode scanners for data, and to retrieve the buffered barcode data from the controller. The software may also instruct the controller to download programs to the barcode scanners, send messages to specific barcode scanners, and to perform additional functions. Refer to Chapter 6, “Starnode DOS Device Driver” for more information.
Software Installation The diskette provided with your Starnode controller contains DOS, Windows 3.11, and DOS compatible driver level software, and utilities for DOS and Windows 95, which may be used to control and test the Starnode network.
2-2
•
For Windows 95 environments, refer to Chapter 5, “Using Starndem” for information on the Starndem utility.
•
When using the Starnode dll for developing Windows applications, refer to Chapter 7, “Writing an Application Program”.
•
For DOS environments using DOS drivers and the Starn utility, refer to Chapter 6, “Starnode DOS Device Driver”.
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002
Page 19
Installing PC-Resident Starnode Board
•
For other environments or for an overview of additional software applications for use with Starnode, refer to Chapter 3, “Starnode Accessories”.
2
1.
Insert the Starnode Developers Disk in drive A:.
2.
If you are running under Windows, open a DOS session.
3.
From the DOS C:> prompt, create a directory on your hard drive to store the software, for example c:\cisoft\starnpc. Change to this directory and enter xcopy a:\*.*. /s. This will re-create the floppy file structure under this subdirectory. Refer to the readme file for a full description of the sub-directories and files on the diskette as well as details on any changes to the programs and drivers.
Installing PC-Resident Starnode Board Installing your Starnode interface board may vary according to the model and manufacturer of your PC. Refer to the documentation provided with your computer for board installation. Install the Starnode interface board as follows. 1.
Touch a grounded metal surface (a desk or cabinet, for example). Static electricity may be built up in your body, especially in rooms with thick carpeting. Discharging the electricity into a grounded object avoids the possibility of damage to components on your Starnode Board or inside your PC.
2.
Turn the power off to your PC.
3.
Loosen all screws that secure the cover of your PC.
4.
Remove the cover of your PC.
5.
Locate an empty ISA slot in your PC. Most PC's provide ample slots for inserting extra printed circuit boards. Loosen and remove the slot cover for that slot. Retain the slot cover and screws for future use.
6.
Being careful to handle it only by the edges, remove the Starnode interface board from its packing material. Do not touch any of the metal contacts on the board.
Rev B, February 2002
Starnode PC Data Collection Network Operator’s Manual
2-3
Installation
To install the software:
Page 20
Chapter
2
Installation
7.
Locate the I/O port address jumpers, labeled JH4 on the board as shown in Figure 2–2.
FIGURE 2–2. I/O Port Address Jumpers
I/O Port Address (0300H)
The board's address is set as 300 (hex) at the factory. This is the default address that SICK Auto Ident, Inc. software uses. If this is not the desired port address, move the jumpers as necessary. The software must also be configured to use the newly set board address. 8.
2-4
For the most commonly used board addresses, refer to Figure 2–3.
Starnode PC Data Collection Network Operator’s Manual Rev B, February 2002