V600 RFID System V600-CD1D-V Serial Interface ID Controller Operation Manual
Manual89 pagesPDF 566 KB
Operation manual for the Omron V600-CD1D-V serial interface ID controller of the V600 RFID system, including the V2 and V3 versions.
Covers · 1 model
The models it covers
Summary
What is in it
The operation manual for the Omron V600-CD1D-V Serial Interface ID Controller, part of the V600 RFID System that reads and writes Data Carriers without contact. It describes features, system configuration and user I/O, part names and dimensions, DIP switch settings, mounting and RS-232C wiring, the command format with a Data Carrier memory map and example program, test runs, diagnostics, error lists, Data Carrier life checks and troubleshooting, with appendices on codes, auto read/write and specifications.
Its parts
- Features and System Configuration
- Nomenclature and Dimensions
- Switch Setting and Wiring
- Communications
- Testing
- Codes
- Auto Read/Auto Write
- Specifications and Ratings
- Conformity to Standards
From the manual
Key facts from this manual
Each line names its page in the PDF.
Operation manual for the Omron V600-CD1D-V serial interface ID controller of the V600 RFID system, which links a host computer over RS-232C to a read/write head. It describes the V600-CD1D-V2 and notes how it differs from the V600-CD1D and V600-CD1D-V3. It explains the switch settings, mounting, wiring, error codes and specifications.
- Power
- 24 VDC (20.4 to 26.4 VDC); 7.2 W max. (24 V, 0.3 A) p. 80
- Recommended supply
- Omron S82K-0124 (100 VAC input) or S82K-2124 (200 VAC input), 24 VDC, 0.6 A p. 28
- Host interface
- RS-232C, 2,400/4,800/9,600/19,200 bps, 15 m max. line, SYSWAY protocol p. 83
- Host connector
- XM2A-0901 plug and XM2S-0911 hood supplied; recommended cable 5PX28AWG, 7 dia. p. 29, 83
- I/O
- Inputs RESET, TRIG, IN1, IN2 (24 VDC, 10 mA typical); outputs RUN, CMPL, OUT1, OUT2 (24 VDC, 100 mA max.) p. 28, 81
- Data per command
- Up to 2 KBytes read or written by batch commands p. 11
- Indicators
- POWER, HEAD and STOP LEDs; monitor shows the end code as a 2-digit hexadecimal number p. 17
- Error codes
- 72 data carrier missing; 7A address over; 7C R/W head not connected; 7D write protect error p. 62
- Error log
- Records up to 30 errors for the host to read p. 61
- Operating temperature
- –10° to 55°C; 35% to 85% RH without condensation p. 80
- Mounting
- Panel mounting with two M4 screws, or DIN rail p. 25, 26
- Weight
- 360 g p. 80
What this manual walks you through
- Setting the mode selector and DIP switches for speed, data format and trigger p. 21, 22
- Testing read and write with a data carrier off-line in TEST mode p. 23
- Using the trigger input to start processing p. 24
- Mounting the controller on a panel or DIN rail p. 25, 26
- Wiring power, ground and the I/O terminals p. 27, 28
- Wiring the RS-232C cable to the host computer p. 29
- Using the user inputs and outputs with a line PLC p. 15
- Reading indicators and error codes p. 61, 62
- Checking the battery of SRAM-type data carriers p. 63
- Checking the controller version p. 83
Good to know
- An inrush current of about 20 A flows at power-on; use a 24 VDC supply of 0.6 A minimum. p. 27, 28
- DIP switch settings are read only at power-on; turn power off before changing them. p. 22
- Do not set the mode selector to positions 7 through 9 in normal operation. p. 21
- Shorting the output terminals without a load may damage the internal transistor. p. 81
- The manual states the V600-CD1D-V3 conforms to EC Directives, while the V600-CD1D-V2 conforms only to UL and CSA standards. p. 12
Questions this manual answers
What power supply does the Omron V600-CD1D-V2 need?
24 VDC within 20.4 to 26.4 VDC, 7.2 W max. Because of an inrush of about 20 A, the manual calls for a supply of 24 VDC, 0.6 A minimum. p. 27, 28
What does error 72 mean on the V600 ID controller?
Data carrier missing: no data carrier was in the read/write area when the command ran. p. 62
What baud rates does the V600-CD1D-V support?
2,400, 4,800, 9,600 or 19,200 bps, set with DIP switch 1. p. 22, 83
Can a V600-CD1D-V2 replace a V600-CD1D?
Yes. The manual describes the V600-CD1D-V2 as an upgraded version that has all V600-CD1D functions plus new features. p. 11
How do I test the V600 controller and head without a host computer?
Use TEST mode on the mode selector: the controller repeatedly reads or writes 1 byte with a data carrier at 1-second intervals and shows the end code. p. 23
The whole text · 9 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file