Page 1 of V600 RFID System V600-CD1D-V Serial Interface ID Controller Operation Manual

Manual · Omron

V600 RFID System V600-CD1D-V Serial Interface ID Controller Operation Manual

Manual89 pagesPDF 566 KB

Operation manual for the Omron V600-CD1D-V serial interface ID controller of the V600 RFID system, including the V2 and V3 versions.

Download the PDF566 KB

Covers · 1 model

The models it covers

Summary

What is in it

The operation manual for the Omron V600-CD1D-V Serial Interface ID Controller, part of the V600 RFID System that reads and writes Data Carriers without contact. It describes features, system configuration and user I/O, part names and dimensions, DIP switch settings, mounting and RS-232C wiring, the command format with a Data Carrier memory map and example program, test runs, diagnostics, error lists, Data Carrier life checks and troubleshooting, with appendices on codes, auto read/write and specifications.

Its parts

  1. Features and System Configuration
  2. Nomenclature and Dimensions
  3. Switch Setting and Wiring
  4. Communications
  5. Testing
  6. Codes
  7. Auto Read/Auto Write
  8. Specifications and Ratings
  9. Conformity to Standards

From the manual

Key facts from this manual

Each line names its page in the PDF.

Operation manual for the Omron V600-CD1D-V serial interface ID controller of the V600 RFID system, which links a host computer over RS-232C to a read/write head. It describes the V600-CD1D-V2 and notes how it differs from the V600-CD1D and V600-CD1D-V3. It explains the switch settings, mounting, wiring, error codes and specifications.

Read for this summary: pages 1 to 2, 9 to 18, 20 to 29, 61 to 63 and 80 to 83 of 89.

Power
24 VDC (20.4 to 26.4 VDC); 7.2 W max. (24 V, 0.3 A) p. 80
Recommended supply
Omron S82K-0124 (100 VAC input) or S82K-2124 (200 VAC input), 24 VDC, 0.6 A p. 28
Host interface
RS-232C, 2,400/4,800/9,600/19,200 bps, 15 m max. line, SYSWAY protocol p. 83
Host connector
XM2A-0901 plug and XM2S-0911 hood supplied; recommended cable 5PX28AWG, 7 dia. p. 29, 83
I/O
Inputs RESET, TRIG, IN1, IN2 (24 VDC, 10 mA typical); outputs RUN, CMPL, OUT1, OUT2 (24 VDC, 100 mA max.) p. 28, 81
Data per command
Up to 2 KBytes read or written by batch commands p. 11
Indicators
POWER, HEAD and STOP LEDs; monitor shows the end code as a 2-digit hexadecimal number p. 17
Error codes
72 data carrier missing; 7A address over; 7C R/W head not connected; 7D write protect error p. 62
Error log
Records up to 30 errors for the host to read p. 61
Operating temperature
–10° to 55°C; 35% to 85% RH without condensation p. 80
Mounting
Panel mounting with two M4 screws, or DIN rail p. 25, 26
Weight
360 g p. 80

What this manual walks you through

  • Setting the mode selector and DIP switches for speed, data format and trigger p. 21, 22
  • Testing read and write with a data carrier off-line in TEST mode p. 23
  • Using the trigger input to start processing p. 24
  • Mounting the controller on a panel or DIN rail p. 25, 26
  • Wiring power, ground and the I/O terminals p. 27, 28
  • Wiring the RS-232C cable to the host computer p. 29
  • Using the user inputs and outputs with a line PLC p. 15
  • Reading indicators and error codes p. 61, 62
  • Checking the battery of SRAM-type data carriers p. 63
  • Checking the controller version p. 83

Good to know

  • An inrush current of about 20 A flows at power-on; use a 24 VDC supply of 0.6 A minimum. p. 27, 28
  • DIP switch settings are read only at power-on; turn power off before changing them. p. 22
  • Do not set the mode selector to positions 7 through 9 in normal operation. p. 21
  • Shorting the output terminals without a load may damage the internal transistor. p. 81
  • The manual states the V600-CD1D-V3 conforms to EC Directives, while the V600-CD1D-V2 conforms only to UL and CSA standards. p. 12

Questions this manual answers

What power supply does the Omron V600-CD1D-V2 need?

24 VDC within 20.4 to 26.4 VDC, 7.2 W max. Because of an inrush of about 20 A, the manual calls for a supply of 24 VDC, 0.6 A minimum. p. 27, 28

What does error 72 mean on the V600 ID controller?

Data carrier missing: no data carrier was in the read/write area when the command ran. p. 62

What baud rates does the V600-CD1D-V support?

2,400, 4,800, 9,600 or 19,200 bps, set with DIP switch 1. p. 22, 83

Can a V600-CD1D-V2 replace a V600-CD1D?

Yes. The manual describes the V600-CD1D-V2 as an upgraded version that has all V600-CD1D functions plus new features. p. 11

How do I test the V600 controller and head without a host computer?

Use TEST mode on the mode selector: the controller repeatedly reads or writes 1 byte with a data carrier at 1-second intervals and shows the end code. p. 23

The whole text · 9 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 8981-89

The file

Revision and size

RevisionCat. No. Z083-E1-04A, Revised December 2004
PublisherOMRON
Pages89
PDF566 KB
TextText from the PDF itself.

The first pages · 3 of 89

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 89
Page 2
Page 2of 89
Page 3
Page 3of 89