Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 9

V600 RFID System V600-CD1D-V Serial Interface ID Controller Operation Manual, pages 81 to 89

Pages 81 to 89 of 89

The original document is the PDF (566 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron V600-CD1D-V2

Page 81

Appendix C

Specifications and Ratings

I/O Specifications External I/O Specifications Input Specifications (RESET, TRIG, IN1, IN2) Input voltage

24 VDC +10%/–15% (including ripple)

Input impedance

2.2 kΩ

Input current

10 mA at 24 VDC (typical)

ON voltage

19 V min.

OFF voltage

5 V max.

Input response time

70 ms max.

Output Specifications (RUN, CMPL, OUT1, OUT2) Max. switching capacity Leakage current

24 VDC +10%/–15% (including ripple), 100 mA

Residual voltage

2.0 V max.

100 µA max

Note 1. When the RESET input is ON, the CPU stops and the STOP indicator light. 2. If the terminals are short-circuited without load, the internal transistor may be damaged.

74

Page 82

Appendix C

Specifications and Ratings Wiring Examples of I/O Devices ID Controller input circuitry

Internal circuit

Internal circuit

RESET 2.2 kΩ

OUT

PLC output unit (C200H-OD211, C500-OD412, etc.)

Internal circuit

COM

+V

OV(COM)

+V

TRIG

2.2 kΩ

IN1

2.2 kΩ

IN2

2.2 kΩ

Sensor internal circuit

NPN transistor output open-collector type (3-line sensor, etc.)

OV

Internal circuit

Output

Contact type (pushbutton switch, etc.)

Internal circuit

24 VDC + Power supply

ID Controller output circuitry

CMPL

Internal circuit

OUT1

Internal circuit

OUT2

Internal circuit

IN

Internal circuit

Internal circuit

RUN

IN Internal circuit

PLC input unit (C200H-ID212, C500-ID218, etc.)

COM

Relay

24 VDC

+

Power supply

Note Use the bi-directional Input Unit on the PC.

75

Page 83

Appendix C

Specifications and Ratings

Communications Specifications The communications specifications conform to RS-232C, and a general-purpose factory computer or personal computer can be connected to the ID Controller. The communications protocol conform to SYSWAY (SYSMAC host computer system).

Host Computer Communications Specifications Standard

RS-232C

Transmission path connection Communications method

Point-to-point

Synchronization method

Start-stop synchronization (stop bit = 1 or 2)*

Transmission rate

2,400/4,800/9,600/19,200 bps*

Transmitted codes

ASCII (7 bits) or JIS*

Communications control procedure Error detection

Point-to-point procedure

Line length

15 m max.

Connector

XM2A-0901 (plug): XM2S-0911 (hood): 5PX28AWG, 7 dia.

Two-line, half-duplex

Vertical parity (even/odd/none)*

Recommended cable

1 set is supplied with ID Controller As an accessory

Note *Set by the internal DIP switch.

Checking the Version The ID Controller version can be checked using the following method. 1. Turn ON the power suppy to the 2. The version will be displayed on the monitor as shown below.

6

76

0

2. 1

Page 84

Appendix D Conformity to Standards

EC Directives We hereby declare that the following products are in conformity with the requirements of the EC Directive listed below: Identification System V600-CD1D-V3 ID Controllers Read/Write Heads Data Carriers No. of Directive: 89/336/EEC Title of Directive: Electromagnetic Compatibility The above referenced products conform to the following standards: Electromagnetic Compatibility EMI (Electromagnetic Interference): Radiated EN50081-2: 1994 / EN55011: 1991 EMS (Electromagnetic Susceptibility): Electrostatic Discharge EN50082-2: 1995 / EN61000-4-2: 1995 RF Electromagnetic Field EN50082-2: 1995 / ENV50140: 1994 RF Common Mode EN50082-2: 1995 / ENV50141: 1994 Electrical Fast Transient Burst EN50082-2: 1995 / EN61000-4-4: 1995 Power-Frequency Magnetic Field EN50082-2: 1995 / EN61000-4-8: 1993

Technical Data Intended Environment: Industrial 1.

Type designation:

V600-CD1D-V3

2.

Host interface:

RS-232C

3.

Number of Read/Write Heads connectable: 1 channel

4.

Rated power supply voltage:

24 VDC

5.

Acceptable power supply voltage:

20.4 to 26.4 VDC

6.

Power consumption:

7.2 W max.

7.

Dielectric strength:

1,000 VAC, between live parts and protective grounding conductor

8.

Ambient air temperature:

Operating –10° to 55°C Storage –25° to 65°C

9.

IP rating (IEC60529):

IP30 (for inner-panel installation)

10. Pollution rating:

2 (controlled environment)

11. Electromagnetic Compatibility (EMC) a)

Field Withstandability:

10 V/m b)

RF Common Mode:

10 V c)

Electrostatic Discharge Withstandability:

4 kV (Contact) 8 kV (Air)

d)

Fast Transient Withstandability:

2 kV (DC power) 1 kV (Signal line)

e)

Radiated Emission:

Class A, Group 1

77

Page 85

Appendix D

Conformity to Standards

Model Legend • ID Controllers

I II III IV

I – V600: II – CD1D:

III – V3: IV –

Inductive Identification System One Read/Write Head connectable – Serial interface – DC power supply model Version 3 Blank – Standard model Suffix(es) – For marketing purposes

• Read/Write Heads V600-H I II III IV V

I – V600: II – H:

Inductive Identification System Read/Write Head

III –

Shape – 0 or 1 –5

IV –

Serial number

V –

Blank – Standard model Suffix(es) – For marketing purposes

Square type Cylindrical type

• Data Carriers V600-D I II III IV V VI

78

I – V600: II – D:

Inductive Identification System Data Carrier

III –

Memory Capacity – 2K 2K bytes – 8K 8K bytes – 23 256 bytes

IV –

Memory type

V –

Serial number

VI –

Blank – Standard model Suffix(es) – For marketing purposes

–R –P

SRAM EEPROM

Page 86

Conformity to Standards

Appendix D

FCC (Federal Communications Commission) FCC Part 15 Subpart B For a Class A digital device or peripheral, the instructions furnished the user shall include the following or similar statement placed in a prominent location in the text of the manual: Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

79

Page 87

Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual.

Cat. No. Z083-E1-04A Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code 1

Date February 1992

Revised content Original production

1A

April 1993

Pages 20, 68 : Recommended cable model corrected.

2

November 1993

Pages 2, 3 : New features of the V600-CD1D-V2 added. Page 3: Clarification made for the bottom part of diagram. Pages 13: DIP Switch 1 data corrected. Pages 34: Table revised. Pages 44 to 46: Subsections 4-4-10 and 4-4-11 added. Pages 55 : Warning code table added. Pages 56 to 60: Subsections 5-4-2 and 5-5 added.

3

August 1998

Information relating to EC Directives added throughout the manual. V600-CD1D-V3 added throughout the manual. “FA ID System” changed to “RFID System” throughout the manual. Appendix D Conformity to Standards added.

04

November 2002

Page 2: V620 deleted in one place. Information on conformance to EN standards added. Page 3: Information on MDS command added to the table. Pages 4, 16: ID Controller model number changed to Page 38: R changed to W in one place. Pages 43, 44, 53, 54, 55: Information on MDS command added in several places. Page 71: Notation for shock specification changed. Page 74: Information on checking the ID Controller version added.

04A

December 2004

Back cover: Addresses changed. Warranty and liability information added to beginning of manual, signal word and alert symbols modified, and style of safety information in the body of the manual changed.

81

Page 88

OMRON Corporation Industrial Automation Company Application Sensors Division Sensing Devices and Components Division H.Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-7107

Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit, Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49)7032-811-0/Fax: (49)7032-811-199 OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, #11-01, UE Square, 239920 Singapore Tel: (65)6835-3011/Fax: (65)6835-2711 OMRON CHINA CO., LTD. BEIJING OFFICE Room 1028, Office Building, Beijing Capital Times Square, No. 88 West Chang’an Road, Beijing, 100031 China Tel: (86)10-8391-3005/Fax: (86)10-8391-3688

Page 89

Authorized Distributor:

Cat. No. Z083-E1-04A

Note: Specifications subject to change without notice.