Page 81
Appendix C
Specifications and Ratings
I/O Specifications External I/O Specifications Input Specifications (RESET, TRIG, IN1, IN2) Input voltage
24 VDC +10%/–15% (including ripple)
Input impedance
2.2 kΩ
Input current
10 mA at 24 VDC (typical)
ON voltage
19 V min.
OFF voltage
5 V max.
Input response time
70 ms max.
Output Specifications (RUN, CMPL, OUT1, OUT2) Max. switching capacity Leakage current
24 VDC +10%/–15% (including ripple), 100 mA
Residual voltage
2.0 V max.
100 µA max
Note 1. When the RESET input is ON, the CPU stops and the STOP indicator light. 2. If the terminals are short-circuited without load, the internal transistor may be damaged.
74
Page 82
Appendix C
Specifications and Ratings Wiring Examples of I/O Devices ID Controller input circuitry
Internal circuit
Internal circuit
RESET 2.2 kΩ
OUT
PLC output unit (C200H-OD211, C500-OD412, etc.)
Internal circuit
COM
+V
OV(COM)
+V
TRIG
2.2 kΩ
IN1
2.2 kΩ
IN2
2.2 kΩ
Sensor internal circuit
NPN transistor output open-collector type (3-line sensor, etc.)
OV
Internal circuit
Output
Contact type (pushbutton switch, etc.)
Internal circuit
24 VDC + Power supply
ID Controller output circuitry
CMPL
Internal circuit
OUT1
Internal circuit
OUT2
Internal circuit
IN
Internal circuit
Internal circuit
RUN
IN Internal circuit
PLC input unit (C200H-ID212, C500-ID218, etc.)
COM
Relay
24 VDC
+
Power supply
Note Use the bi-directional Input Unit on the PC.
75
Page 83
Appendix C
Specifications and Ratings
Communications Specifications The communications specifications conform to RS-232C, and a general-purpose factory computer or personal computer can be connected to the ID Controller. The communications protocol conform to SYSWAY (SYSMAC host computer system).
Host Computer Communications Specifications Standard
RS-232C
Transmission path connection Communications method
Point-to-point
Synchronization method
Start-stop synchronization (stop bit = 1 or 2)*
Transmission rate
2,400/4,800/9,600/19,200 bps*
Transmitted codes
ASCII (7 bits) or JIS*
Communications control procedure Error detection
Point-to-point procedure
Line length
15 m max.
Connector
XM2A-0901 (plug): XM2S-0911 (hood): 5PX28AWG, 7 dia.
Two-line, half-duplex
Vertical parity (even/odd/none)*
Recommended cable
1 set is supplied with ID Controller As an accessory
Note *Set by the internal DIP switch.
Checking the Version The ID Controller version can be checked using the following method. 1. Turn ON the power suppy to the 2. The version will be displayed on the monitor as shown below.
6
76
0
2. 1
Page 84
Appendix D Conformity to Standards
EC Directives We hereby declare that the following products are in conformity with the requirements of the EC Directive listed below: Identification System V600-CD1D-V3 ID Controllers Read/Write Heads Data Carriers No. of Directive: 89/336/EEC Title of Directive: Electromagnetic Compatibility The above referenced products conform to the following standards: Electromagnetic Compatibility EMI (Electromagnetic Interference): Radiated EN50081-2: 1994 / EN55011: 1991 EMS (Electromagnetic Susceptibility): Electrostatic Discharge EN50082-2: 1995 / EN61000-4-2: 1995 RF Electromagnetic Field EN50082-2: 1995 / ENV50140: 1994 RF Common Mode EN50082-2: 1995 / ENV50141: 1994 Electrical Fast Transient Burst EN50082-2: 1995 / EN61000-4-4: 1995 Power-Frequency Magnetic Field EN50082-2: 1995 / EN61000-4-8: 1993
Technical Data Intended Environment: Industrial 1.
Type designation:
V600-CD1D-V3
2.
Host interface:
RS-232C
3.
Number of Read/Write Heads connectable: 1 channel
4.
Rated power supply voltage:
24 VDC
5.
Acceptable power supply voltage:
20.4 to 26.4 VDC
6.
Power consumption:
7.2 W max.
7.
Dielectric strength:
1,000 VAC, between live parts and protective grounding conductor
8.
Ambient air temperature:
Operating –10° to 55°C Storage –25° to 65°C
9.
IP rating (IEC60529):
IP30 (for inner-panel installation)
10. Pollution rating:
2 (controlled environment)
11. Electromagnetic Compatibility (EMC) a)
Field Withstandability:
10 V/m b)
RF Common Mode:
10 V c)
Electrostatic Discharge Withstandability:
4 kV (Contact) 8 kV (Air)
d)
Fast Transient Withstandability:
2 kV (DC power) 1 kV (Signal line)
e)
Radiated Emission:
Class A, Group 1
77
Page 85
Appendix D
Conformity to Standards
Model Legend • ID Controllers
I II III IV
I – V600: II – CD1D:
III – V3: IV –
Inductive Identification System One Read/Write Head connectable – Serial interface – DC power supply model Version 3 Blank – Standard model Suffix(es) – For marketing purposes
• Read/Write Heads V600-H I II III IV V
I – V600: II – H:
Inductive Identification System Read/Write Head
III –
Shape – 0 or 1 –5
IV –
Serial number
V –
Blank – Standard model Suffix(es) – For marketing purposes
Square type Cylindrical type
• Data Carriers V600-D I II III IV V VI
78
I – V600: II – D:
Inductive Identification System Data Carrier
III –
Memory Capacity – 2K 2K bytes – 8K 8K bytes – 23 256 bytes
IV –
Memory type
V –
Serial number
VI –
Blank – Standard model Suffix(es) – For marketing purposes
–R –P
SRAM EEPROM
Page 86
Conformity to Standards
Appendix D
FCC (Federal Communications Commission) FCC Part 15 Subpart B For a Class A digital device or peripheral, the instructions furnished the user shall include the following or similar statement placed in a prominent location in the text of the manual: Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
79
Page 87
Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No. Z083-E1-04A Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code 1
Date February 1992
Revised content Original production
1A
April 1993
Pages 20, 68 : Recommended cable model corrected.
2
November 1993
Pages 2, 3 : New features of the V600-CD1D-V2 added. Page 3: Clarification made for the bottom part of diagram. Pages 13: DIP Switch 1 data corrected. Pages 34: Table revised. Pages 44 to 46: Subsections 4-4-10 and 4-4-11 added. Pages 55 : Warning code table added. Pages 56 to 60: Subsections 5-4-2 and 5-5 added.
3
August 1998
Information relating to EC Directives added throughout the manual. V600-CD1D-V3 added throughout the manual. “FA ID System” changed to “RFID System” throughout the manual. Appendix D Conformity to Standards added.
04
November 2002
Page 2: V620 deleted in one place. Information on conformance to EN standards added. Page 3: Information on MDS command added to the table. Pages 4, 16: ID Controller model number changed to Page 38: R changed to W in one place. Pages 43, 44, 53, 54, 55: Information on MDS command added in several places. Page 71: Notation for shock specification changed. Page 74: Information on checking the ID Controller version added.
04A
December 2004
Back cover: Addresses changed. Warranty and liability information added to beginning of manual, signal word and alert symbols modified, and style of safety information in the body of the manual changed.
81
Page 88
OMRON Corporation Industrial Automation Company Application Sensors Division Sensing Devices and Components Division H.Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-7107
Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit, Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49)7032-811-0/Fax: (49)7032-811-199 OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, #11-01, UE Square, 239920 Singapore Tel: (65)6835-3011/Fax: (65)6835-2711 OMRON CHINA CO., LTD. BEIJING OFFICE Room 1028, Office Building, Beijing Capital Times Square, No. 88 West Chang’an Road, Beijing, 100031 China Tel: (86)10-8391-3005/Fax: (86)10-8391-3688
Page 89
Authorized Distributor:
Cat. No. Z083-E1-04A
Note: Specifications subject to change without notice.
Printed in Japan 1204-0.5C (0292) (A)