For the Omron V600-CD1D-V2

Page 11

Section

Features

1-1

1-1

Features V600 RFID System offers powerful support to the automation of large-scale distributed control systems and multi-model small-scale production systems by means of contactless data communication.

Easy to Use

• Significantly shortens the communication tact time with moving pallets. • A RS-232C interface that can be connected to a general-purpose factory computer or personal computer is provided. Using simple commands, a large quantity of data can be processed easily. • Compact size allows for flexible applications within increasingly complicated production systems. • Up to 2 KBytes of data can be read/written by batch commands, thus shortening the work processing time. • The write command repeat function simplifies data transmission between the ID Controller and host controller. • Two user inputs and two user outputs that can be manipulated by commands help reduce system organization costs. • Command end codes are displayed on-screen for checking operating status and facilitating system maintenance. • Records up to 30 errors which may occur during operation for the quick investigation into causes of system abnormalities. • Testing communications with a Data Carrier (DC) can be performed off-line. This facilitates installation of the Read/Write (R/W) Head and DC when organizing the system. • Conforms to EN standards. The V600-CD1D-V3 and newer versions conform to EN standards (EN 50081-2, EN 50082-2).

Comparing the V600-CD1D and V600-CD1D-V2 The V600-CD1D-V2 incorporates all the functions of the V600-CD1D plus the following new features. It is possible to replace the V600-CD1D with the V600-CD1D-V2 which is simply an upgraded version of the V600-CD1D. Connecting to EEPROM-type (Batteryless-type) Data Carrier

2

The V600-CD1D-V2 makes it possible to write and read data to and from the EEPROM-type (batteryless-type) Data Carrier (DC). The

Page 12

Section

Features

1-1

V600-CD1D-V2 has two modes: the distance priority mode and speed priority mode, which are selected with DIP switch 1 for reading data from the EEPROMtype DC. These modes does not work with SRAM-type DCs. DIP Switch 1

Note The V600-CD1D-V2 is set to local communications mode when SW7 is ON. New Commands

Function Checking data

Checking the number of overwriting operations

The V600-CD1D-V2 incorporates the following new data management commands in order to confirm the reliability of the internal data of the Data Carrier (DC). Command

Processing contents

MDK

By adding a check code to the internal data of the DC, any data errors due to the SRAM-type DC battery or the number of overwriting operations of the EEPROM-type DC will be detected.

MDC

The MDK command is used to read the check code and the MDC command is used to check the check code. The MDK command is always used in combination with the MDC command.

MDL

By counting the number of overwriting operations, the life of the EEPROM-type DC will be detected. The EEPROM-type DC can be overwritten 100,000 times. The life of the EEPROM-type DC will be detected by using a preset number of overwriting operations.

MDS

Flashing Monitor Function

If an error occurs, the display for the code monitor flashes. The display does not flash if the normal end code or warning code is returned.

Note The MDS command can be used on ID Controller version 2.1 or later. See page 76 for instructions on checking the version.

Comparing the V600-CD1D-V2 and V600-CD1D-V3 The V600-CD1D-V3 conforms to EC Directives while the V600-CD1D-V2 only conforms to UL and CSA standards.

3

Page 13

Section

System Configuration

1-2

1-2

System Configuration Being equipped with a serial interface conforming to RS-232C, the ID Controller can communicate with general-purpose factory computers (FC) and personal computers (IBM XT/AT compatible). Communications processing is performed using the commands from a host computer (FC, IBM XT/ AT compatible) in the RUN mode.

Factory computer

Personal computer

Read/Write Head or Read/Write Antenna

Data carrier, pallet, etc.

4

ASCII Unit

Page 14

Section

Outline of Operation

1-3

1-3

Outline of Operation Host computer: FC, IBM XT/AT

ID Controller

R/W Head or R/W Antenna

Reading data specifying processing

Data carrier Programmable Controller (PC) Pallet

To next processing Pallet

Processing/inspection

When a command is sent from the host computer (FC, IBM XT/AT compatible) to the ID Controller, the R/W Head (or R/W Antenna) enters the stand-by state, waiting for a signal from the DC. When a DC enters the area where it can communicate with the R/W Head, the data (model number and data for processing or inspection) of a memory area specified by the command can be written or read to or from the DC or a response transmitted to the host computer. For example, when the memory contents of the DC have been read, the host computer transmits a command on how to process or test a workpiece to a Programmable Controller (PC). When the processing or testing has been completed, the PC transmits process or test data to the host computer.

5

Page 15

Section

User I/O

1-4

1-4

User I/O The ID Controller is equipped with two user outputs that can be turned ON/OFF by a command from the host controller, and also two user inputs whose ON/OFF status can be read. These I/Os can be manipulated independently of each other, so that ON/OFF signals can be processed easily and at low cost by a host computer. The following figure shows an example in which the ID Controller is used for batch reading of test data.

Host computer for collecting inspection data Line control end input ID Controller

Line control PC

Data collection end output

To next processing

Inspection processing Workpiece to be inspected

Pallet Conveyor

Outline of Operation 1, 2, 3...

6

1. When there is a workpiece to be tested, the PC controlling the line instructs the conveyor to stop the workpiece at a predetermined place. 2. When the workpiece has been stopped, the PC issues a signal indicating that the line control action has been completed. 3. A host computer reads the signal to the ID Controller through a user input, and reads the test data. 4. When the test data has been read, the host computer issues a data collection completion signal through the user output of the ID Controller. 5. In response to the data collection completion signal, the PC sends the workpiece to the next process.

Page 16

SECTION 2 Nomenclature and Dimensions This section provides the names and functions of the ID Controller parts as well as the ID Controller’s dimensions. 2-1 2-2

Names and Functions of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8 10

7

Page 17

Section

Names and Functions of Parts

2-1

2-1

Names and Functions of Parts Protective conductor Power terminals terminal

External input terminals (4 points, 1 common points) Switch cover

RS-232C interface connector V600-CD1D-V3

Monitor display LED operation indicators R/W Head connector

External output terminals (4 points, independent common)

Operation Indicators Name

Color

Function

POWER

Green

Lit when power is supplied.

HEAD

Yellow

Lit when R/W Head is executing communications processing.

STOP

Red

Lit when an error (such as CPU error or memory error) has occurred or when external reset signal has been input.

Monitor Display 1, 2, 3...

1. Error Display Mode: Displays end code of command processing. The end code is displayed as a 2-digit hexadecimal number.

Hexadecimal

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

Indication

0

1

2

3

4

5

6

7

8

9 a b c d e f

2. I/O Display Mode: Displays the ON/OFF status of the I/O terminal and indicates the occurrence of an error. Indication of input status (From the left: RESET, TRIG, IN1, and IN2)

Error indication

Indication of output status (From the left: RUN, CMPL, OUT1, and OUT2)

Note The Display Mode is set by the internal DIP switch.

8

Page 18

Section

Names and Functions of Parts

2-1

Power Supply and External Output Terminals Name

Function

24VDC/0V

Supplies 24 VDC

GR

Protective conductor terminal. Connect a ground line grounded at less than 100 Ω. External reset input for emergency stop.

RESET TRIG

Trigger input informing the Controller of the processing start time of the DC. The conditions under which this input signal is to be issued can be set by the DIP switch.

IN1

User input 1 that can be manipulated by a command.

IN2

User input 2 that can be manipulated by a command.

COM

Common input terminal.

External Output Terminals Name

Function

RUN

Turns ON when the ID Controller operates normally and can communicate with the host controller. This signal is turned OFF in the test mode.

CMPL

Turns ON when communications with the DC have been completed, and turns OFF when transmission of a response has started.

OUT1

User output 1 that can be manipulated by a command.

OUT2

User output 2 that can be manipulated by a command.

R/W Head Connector

Connects the R/W Head (R/W Antenna).

RS-232C Interface Connector

Connector for communications with the host computer. Conforming to RS-232C, this connector can be connected to a general-purpose factory computer or personal computer.

9

Page 19

Section

Dimensions

2-2

Dimensions

18 53

68 17.5

5.5

81 92

Two, 4.5-dia 115

53

81

10

2-M4

2-2

Page 20

SECTION 3 Switch Setting and Wiring This section provides the DIP switch settings and wiring instructions required before operating the ID Controller. 3-1 3-2 3-3 3-4 3-5 3-6

DIP Switch Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting of ID Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-232C Interface Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12 16 16 17 18 20

11