Manual · Omron
4700 Series Installation and Operating Manual for MC4700, MCF4700, MCJ4700, MS4700 & MSF4700 Series
Manual101 pagesPDF 1.4 MB
Installation and operating manual for the STI 4700 Series safety light curtains (MC4700, MCF4700, MCJ4700, MS4700, MSF4700).
Covers · 1 model
The models it covers
Summary
What is in it
The installation and operating manual for the 4700 Series safety light curtains from Scientific Technologies Inc. (STI), covering the MC4700, MCF4700, MCJ4700, MS4700 and MSF4700 transmitters and receivers with the LCM metal chassis or DIN box controller. It explains safety warnings, operating states and modes, channel select and floating blanking, diagnostics, outputs, safe mounting distance formulas, installation and wiring to the machine control circuit, checkout and test procedures, troubleshooting, specifications and DeviceNet operation.
Its parts
- Important Safety Warnings
- Significant Features
- System Access, Components and Indicators
- System Operation
- Detection Options
- Diagnostic and Test Features
- Outputs
- Safe Mounting Distance
- Installation
- Connecting To The Machine Control Circuit
- Checkout and Test Procedures
- Troubleshooting
- Cleaning
- Specifications and Additional Information
- Others
From the manual
Key facts from this manual
Each line names its page in the PDF.
Installation and operating manual from Scientific Technologies (STI) for the 4700 Series safety light curtains: MC4700, MCF4700, MCJ4700, MS4700 and MSF4700, used with the LCM DIN or metal chassis controllers. It covers operating modes, detection options, safe mounting distance, installation, wiring to the machine control circuit, checkout and testing. It also gives troubleshooting codes, specifications and spare part numbers.
- Device
- Safety light curtain: transmitter and receiver with an LCM metal enclosure or DIN controller p. 2
- Protective height
- 12 mm resolution: 100 to 1200 mm; 14 and 20 mm: 150 to 1800 mm; 30 mm: 150 to 1800 mm p. 51
- Operating range
- MC4700 SR: 0.2 to 3 m (12 mm), 0.3 to 5 m (14 mm), 0.3 to 7 m (20 or 30 mm); LR: 0.2 to 5 m (12 mm), 0.3 to 12 m (20 or 30 mm) p. 51
- Safety outputs
- DIN and solid-state controllers: two PNP, 625 mA each at 24 VDC; relay metal chassis: 1 N.O. and 1 N.C./N.O., 6 A at 230 VAC p. 52
- Auxiliary outputs
- DIN and solid-state controllers: one NPN sinking 100 mA and one PNP sourcing 250 mA at 24 VDC; relay version: 1 N.O./N.C., 3 A at 230 VAC p. 52
- Power
- DIN and solid-state controllers: 24 VDC ± 20%, 2 A (STI part number 42992 or equivalent); relay metal chassis: 100 - 230 VAC @ 30 VA p. 52, 53
- Response time
- MC4700, 12 mm, solid-state output: 7.5 mS at 100 mm height up to 25.8 mS at 1200 mm p. 53
- Resolution with blanking
- 1-beam or 2-beam floating blanking: 12 mm becomes 19 or 26 mm; 14 mm 25 or 36 mm; 20 mm 31 or 42 mm; 30 mm 52 or 74 mm p. 52
- Light source
- GaAlAs light emitting diode, 850 nm p. 53
- Cable length
- Up to 30 m from controller to transmitter and receiver; DIN system OSSD and AUX outputs up to 75 m with shielded cable p. 53
- Environment
- 0 to 55° C (32 to 131° F); 95% relative humidity maximum, non-condensing p. 53
- Enclosure rating
- Transmitter and receiver IP65; controller IP20 (DIN mount) or IP65 (metal chassis) p. 53
- DIN controller cables
- Receiver MC47RC03, MC47RC10, MC47RC30 (60567-1030, 60567-1100, 60567-1300); transmitter MC47TC03, MC47TC10, MC47TC30 (60568-0030, 60568-0100, 60568-0300) p. 89
- Accessories
- Test objects 42800-0200 (12 mm), 42800-0240 (14 mm), 42800-0110 (20 mm), 42800-0220 (30 mm); RM-1 43763-0010; RM-3 43983-0010; LCM1 controller 70116-1000 p. 87, 89
What this manual walks you through
- Reading the two-digit diagnostic codes and correcting faults p. 48, 49, 50
- Testing with exact channel select or floating blanking active p. 48
- Cleaning the transmitter and receiver filters p. 50
- System specifications and response time tables p. 51, 52, 53
- Ordering spare MC4700 transmitters and receivers p. 57
- LCM controller spare part numbers p. 87
- Cable, test object and resource module part numbers p. 89
- Calculating the safe mounting distance p. 4
- Connecting to the machine control circuit through an RM-1 module, force-guided relays or a safety monitoring device p. 5
Good to know
- Exact channel select may require a hard barrier guard, and floating blanking requires a larger safety distance. p. 48
- With exact channel select or floating blanking in use, the controller should be in an enclosure with supervisor-controlled access. p. 48
- The 24 VDC power supply must meet IEC 60204-1 and IEC 61496-1. p. 52
- MC4700-12 is available only up to 1200 mm protective height. p. 53
Questions this manual answers
What does code 59 mean on the MC4700 controller display?
A 24 VDC power supply fault; check that the supply to the unit is 24 VDC ± 20%. p. 50
What does code 53 mean on a 4700 light curtain?
The transmitter and receiver lengths do not match, or they are not connected; check that both have the same protected height and are properly connected. p. 50
The MC4700 display shows 01. What do I do?
Normal operation waiting for a start signal: press and release the start switch. p. 48
What is the part number of the 10 m receiver cable for the MC4700 DIN controller?
MC47RC10, part number 60567-1100. p. 89
What is the spare receiver for a 12 mm, 300 mm MC4700?
Receiver MC47-12-300-R; the matching transmitter is MC47__-12-300-X with SR or LR selected. p. 57
The whole text · 11 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file