For the Omron MC4700

Page 91

.....

A PPENDIX A, C HECKOUT P ROCEDURE A.1 CHECKOUT PROCEDURE LOG The following checkout procedure must be performed by qualified personnel during initial 4700 system installation and at least every three months or more frequently depending on machine usage and company guidelines.

Machine Identification:_______________________________Date:_______________

Item

Condition

1. Verify that the guarded machine is compatible with the type of machine which maybe used with the 4700 system. See Section 1 - Important Safety Warnings for further information.

❏ Pass ❏ Fail

2. Verify that the mounting distance of the 4700 system is equal to or greater than the minimum safe distance from the danger point. See Section 8 - Safe Mounting Distance for further information.

❏ Pass ❏ Fail

3. Determine that all access to the danger point not protected by the 4700 system is guarded by other means, such as gates, fencing or other approved methods. Verify that all additional guarding devices are installed and operating properly.

❏ Pass ❏ Fail

4. Make sure the operator is not able to stand between the 4700 detection zone and the machine danger point. Verify that the light curtain can only be reset from a position outside and within view of the hazardous machine area.

❏ Pass ❏ Fail

5. Inspect the electrical connections between the guarded machine’s control system and the 4700 system. Verify that they are properly connected to the machine such that a stop signal from the 4700 system results in an immediate halt of the machine’s cycle. See Section 10 - Connecting To The Machine Control Circuit.

❏ Pass ❏ Fail

6. If the MPCE monitoring feature is not used, proceed to step 7. To test the MPCE feature, verify that the feature has been enabled. Turn the machine power on. Cycle the machine. Place a temporary jumper wire between the MPCE connections. The 4700 should enter a alarm condition. Remove the temporary jumper. Press and release the start button.

❏ Pass ❏ Fail

7. Record the test results in the machine log, then perform the Test Procedure.

❏ Pass ❏ Fail

Comments

Technician Signature:____________________________________________________________________

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

89

Page 92

15

A PPENDIX B, T EST P ROCEDURE B.1 TEST PROCEDURE LOG The following test procedure must be performed by qualified personnel during initial 4700 system installation, according to the employer’s regular inspection program and after any maintenance, adjustment or modification to the 4700 system or the guarded machine. Testing ensures that the light curtain, safety system, and machine control system work together to properly stop the machine. Failure to test properly could result in serious injury to personnel. To test the 4700 system, use the correct size test object.

Machine Identification:_______________________________Date:_______________ Item

Condition

1. Disable the guarded machine. Apply power to the 4700 system.

❏ Pass ❏ Fail

2. Visually inspect the machine to ensure that access to the danger point is only through the 4700 detection zone. If not, additional guarding, including mechanical barriers may be required. Verify that all additional guarding devices and barriers are installed and operating properly.

❏ Pass ❏ Fail

3. Verify that the mounting distance of the 4700 system is equal to or greater than the calculated minimum safety distance from the danger point. See Section 8 - Safe Mounting Distance for further information. Ensure that the operator is not able to stand between the 4700 detection zone and the danger point.

❏ Pass ❏ Fail

4. Check for signs of external damage to the 4700 system, the machine and the electrical cables and wiring. If damage is found, lock the machine off and report to the supervisor.

❏ Pass ❏ Fail

5. Interrupt the 4700 detection zone with the proper size test object. Move the test object inside the perimeter (along the top, sides and bottom) of the detection zone and up and down through the center. At least one Individual Beam Indicator must be lit while the test object is anywhere in the detection zone. If in automatic start mode, verify that the red machine stop light is lit. If in start/restart interlock mode, verify that the red machine stop and yellow interlock lights are on. Press and release start button before proceeding to step 6.

❏ Pass ❏ Fail

6. Start the machine. While the machine is in motion, interrupt the detection zone with the test object. The machine should stop immediately. Never insert the test object into the dangerous parts of the machine. With the machine at rest, interrupt the detection zone with the test object. Verify that the machine will not start with the test object in the detection zone.

❏ Pass ❏ Fail

7. Verify that the braking system is working properly. If the machine does not stop fast enough, adjust the braking system or increase the distance from the detection zone to the danger point.

❏ Pass ❏ Fail

8. If the safety devices or the machine fails any of these tests, do not run the machine. Immediately tag or lockout the machine to prevent its use and notify the supervisor.

❏ Pass ❏ Fail

Comments

Technician Signature:____________________________________________________________________

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

90

Page 93

.....

A PPENDIX C, D EVICE N ET O PERATING I NSTRUCTIONS ! WARNING! DeviceNet is not a safety rated system and is only used to provide status ▲ information. Never use information provided by DeviceNet to control a machine.

C.1 INTRODUCTION The 4700 systems are available which allow communication of non-safety, monitoring and diagnostic information across the DeviceNet BUS.

C.2 FEATURES, Connects to network using simple removable terminal blocks, The following information is available to DeviceNet: C.2.1

S YSTEM IDENTIFICATION, Manufacturer, Product Name, Product Serial Number C.2.2

S YSTEM STATUS, Operating Mode, Detection zone, Safety Outputs, Signal Strength, Number of Beams Installed, Number of Beams Selected C.2.3

S YSTEM S ETTINGS, Operating Mode/Automatic Start/Start interlock, MPCE Monitoring Enabled/Disabled, 1-Beam Floating Blanking Active/Inactive, 2- Beam Floating Blanking Active/Inactive, Exact Channel Select Active/Inactive, Blanking pattern for Exact Channel Select

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

91

Page 94

15

C.2.4

D IAGNOSTIC I NFORMATION, Receiver Diagnostic Codes, Signal Strength, Error Code, Error Description, Device Serial Number

An Electronic Data Sheet (EDS) is supplied with each controller to assist in device configuration. Table C-1 Specifications for 4700 System Controller with DeviceNet

(See main 4700 system manual for additional system specifications) DeviceNet Power

DeviceNet Configuration

Poll, Bit Strobe and COS I/O Assembly Instances

24 VDC, 50 mA - Supplied by deviceNet BUS Network Vendor Code: 405 (Scientific Technologies Inc.) Device Type: 130 (Safety Light curtain) Product Code: 6 (4700 series) Connection Type Supported: Explicit Messages, Poll, Strobe, Change of State MAC ID: 0-63 (network confirmed, 63 is default) Baud Rate Supported: 125K, 250K, 500K (network configured, 125K is default) EDS File Name: 4700.eds Bit Map Icon File Name: 4700.bmp, 4700.ico EDS and Bitmap files supplied on 3-1/2” disk 4700 device I/O assemblies consist of:, Poll and Bit Strobe: Product specific input assembly containing operating mode detection zone status, safety output status, MTS and Remote Start input status, Exact Channel Select and Floating Blanking switch settings., COS: Product specific input assembly containing operating mode.

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

92

Page 95

..... Table C-2 4700 Status Information Sent in Response to a poll command

Instance

Byte

Bit 7

Bit 6

Bit 5

0 Controller alarm

1

Receiver alarm

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Exact Channel Mode

Restart interlock Mode

Start interlock Mode

Automatic Start Mode alarm (Lockout)

MPCE Monitoring Enabled

Detection Zone machine stop machine run interlock

2 1

2-Beam Floating Blanking

3

1-Beam Floating Blanking

Weak Signal

4

Receiver Diagnostic codes

5

Number of Beams in Curtain

6

Number of Exact Channel Select Beams

7 Table C-3 I/O Data for Change of State

The following is I/O Assembly data attribute format response data for a Change of State. A Change of state message is sent when any of the mode signals in byte 0 changes. All the information in byte 0 will be monitored and sent for change of State messaging. Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

2

0

N/A

N/A

N/A

Exact Channel Select

Restart interlock Mode

Start interlock Mode

Automatic Start Mode alarm (Lockout)

Table C-4 I/O Data

The following is the I/O Assembly data attribute format for Exact Channel Select Blanking Pattern and is sent through Explicit Messaging. Two DeviceNet messages will be sent to provide the total listing of specific beams being blanked.

Beam Number

Bit

R

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

93

Page 96

15

C.3 BASIC DEVICENET NETWORK CONNECTIONS The figure below illustrates the basic wiring principles used to integrate STI products into a small DeviceNet network. In this basic network, Phoenix style screw connectors and M12 micro-style connectors are used to connect this communication system together. Our LCM-2XX series controllers use the M12 micro-style connectors conforming to the DeviceNet standard. DeviceNet Trunk End

DeviceNet Trunk End

1 2 3 4 5

1 2 3 4 5

121

1 2 3 4 5 Screw Connectors

+

Screw 1 2 3 4 5 Connectors

1 2 3 4 5 Screw Connectors

DeviceNet5-pin/Conductor Female Micro style (M12) cable

–

Earth Ground

M12, Micro-style 1 2 3 4 5 Connector

DeviceNet5-pin/Conductor Female Micro style (M12) cable

V1 11 to 24 VDC Power Supply

121

12345 Master Controller

Screw 1716 15 1413 Connector

LCM-2 Series with DeviceNet option

LCM-2XX, LCM-Nema with DeviceNet option

Figure C-1 Basic DeviceNet configuration

C . 4 L C M - 2 X X S E R I E S I N T E R N A L D- N E T W I R E C O L O R S A N D P I N O U T S The following internal connections are in compliance with the electrical requirements of the DeviceNet standard however, the internal connections of these Nema controllers do not follow the wire insulation color code as outlined by that standard. When using the Nema type enclosure the internal DeviceNet Interface (Daughter Board) is connected to a pre-manufactured 5-wire M12 micro-style connector to a 5-pin Phoenix Style screw connector. The M12 male connector as shown in figure 2, provides the external connection for the network.

C.4.1

S CREW C ONNECTORS FOR LCM-2XX SERIES D-N ET INTERFACE MODULE

The following figure illustrates the wire insulation colors and pin outs for the screw connectors on the DeviceNet Interface (Daughter Board). Shown are the following designations for the internal screw type connector: 1.V_: (blue) 2.CAN_Low: (gray) 3.Drain: (brown) 4.CAN_High: (black) 5.V+: (white)

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

94

Page 97

..... Network Connector (Female Contacts)

5 – V+ (White) 4 – CAN-H (Black) 3 – Drain (Brown) 2 – CAN-L (Gray) 1 V- (Blue)

1 2 3 4 5 Device Connector (Male Contacts)

Figure C-2 Pin Outs for Internal Screw Connectors used internally in the LCM-2XX

C.4.2

M-12 M ICRO _S TYLE CONNECTOR FOR LCM-2 XX SERIES

The Nema box controllers offer an optional M-12 micro-style connector for external connection to a DeviceNet Network with the following pin out definition. The micro_style connectors (Fig 2, internal colors correspond to the M12 connector used on the LCM-2XX series controller). 1.Drain (brown) 2.V+ (white) 3.V_ (blue) 4.CAN_High (black) 5.CAN_Low (gray)

4

3

1

2

5

1 – Drain (Brown) 2 – V+ (White) 3 – V– (Blue) 4 – CAN-H (Black) 5 – CAN-L (Gray)

Figure C-3 Pin Outs for Micro_Style Connectors

Note : Device-Net requires that connectors on devices must have male contacts.

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

95

Page 98

15

C.4.3

LCM-2 , MC4700 D IN CONTROLLER EXTERNAL D EVICE -N ET CONNECTION

STI provides a 5-pin Phoenix-style connector for the LCM-2 controller. The MC4700 includes a reference to this connection in its manual in section 3, figure 3-4. The connections are also shown in figures 10-2 and 10-3. The following figure illustrates the wire insulation colors and pin outs for the screw connectors on the LCM-2 Din module. Note: The DeviceNet wiring pin out for the LCM-2 is the opposite or mirror image of the DeviceNet standard so, a standard network connection may have to be re-wired for this controller. Network Connector (Female Contacts)

17 – V- (Black) 16 – CAN-L (Blue) 15 – Drain (Bare) 14 – CAN-H (White) 13 V+ (Red)

13 14 15 16 17 Device Connector (Male Contacts)

Figure C-4 Pin Outs for Phoenix-style connectors used in the STI MC4700, LCM-2 interface

C.5 DEVICENET CONFIGURATION SWITCHES To accommodate DeviceNet configuration switches the LCM-2 (DIN version only) has DIP switches located near the bottom of the Power/Device-Net board. This board is located on the top side of the DIN module and looks similar to figure 1.

1 2 3 JMP 1

OFF = 0

ON = 1

SW1

1 2 3 4 5 6 7 8

16 15 14 13 12 11 10 9

Figure C-5 LCM-2 Power/DeviceNet board

These DIP switches can be used to set the Device-Net Baud Rate and Node number on the LCM-2 controller. When all of the switches are set to “1” or “ON” the LCM-2 is programmable via software using a dedicated Device-Net configuration tool. When the DIP switches are used to set the DeviceNet configuration, use the following table to define the Baud Rate and the Node number. Note: The Node number setting is a binary number from 0 to 63. R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

96

Page 99

..... C.5.1

S WITCH F UNCTION S ELECTION D ESCRIPTION Switch

Function Selection

Description

1

Node Number 0 – 63 Default Setting = 63

000000 = 0, Node 0

2

000001 = 1, Node 1

3

000010 = 2, Node 2

4

000011 = 3, Node 3

5

Etc.,

6

111111 = 63, Node 63

7

Baud Rate 125K – 500K Default = Programmable

8

00 = 125K 01 = 250K 10 = 500K 11 = Programmable Node and Baud Rate via network software

Table C-5 Configuration Switches for Device-Net

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

97

Page 100

15

C.6 QUICK DISCONNECT OPTION Refer to the diagrams below for installation.

8 7 6 5 4 3 2 1

5 4 3 2 1 TB5

RX

TX

Optional Quick Disconnect TB6

1 2 3 4 5 OPTIONAL DEVICENET BOARD

TB1

J3

Figure 15-1 DeviceNet Install Location

DeviceNet TB-1 WHT 5 4 3 2 1

BLK BRN GRY BLU

Plastic Connector V+ 2 4 1 5 3

CAN HI GND (DRAIN) CAN LO

1

2 5 3

4

V– Optional M12 Connector

Figure 15-2 DevieNet Wiring with Optional M12 Connector

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

98