4700 Series Installation and Operating Manual for MC4700, MCF4700, MCJ4700, MS4700 & MSF4700 Series, pages 21 to 30

Pages 21 to 30 of 101

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron MC4700

Page 21

..... - After programming or activating Channel Select or Floating Blanking, to avoid unexpected areas where the system may not sense an intrusion into the detection zone, use a proper size test object to perform the STI Test Procedure.

5.1 E X A C T C H A N N E L S E L E C T ( E C S ) ECS disables selected, fixed areas of the detection zone by masking off specific, fixed beam locations. ECS is helpful when stationary objects such as tooling and fixtures permanently obstruct a portion of the detection zone. ECS requires that any portion of the detection zone which is blocked remain blocked. If the obstruction is removed the 4700 system will enter a machine stop state. When selecting channels to be masked, one channel must remain unblocked. A channel is defined as one transmitter/receiver pair or “beam”. See Table 5-1, “System Response to Exact Channel Select” for a diagram of 4700 system response during operation with ECS active. Table 5-1 System Response to Exact Channel Select Channel Select Status

Exact Channel Select Inactive

Exact Channel Select Inactive

Exact Channel Select Active

Exact Channel Select Active

Exact Channel Select Active machine run machine stop machine run machine stop machine stop

Channel 1 Channel 2 Channel 3 Channel 4 Channel 5... System Response

5.2 M U L T I C H A N N E L S E L E C T ( M C S ) MCS stores up to four patterns of selected beams. Just as the ECS disables selected, fixed areas of the detection zone by masking off specific, fixed beam locations, the MCS can be programmed to store four different patterns. MCS is helpful when a machine requires multiple setups where stationary objects such as tooling, fixtures, or material frequently obstruct a portion of the detection zone. Access and programming is performed using a PLC or switch inputs. The suggested logic patterns for identification of the stored program are in Table 5-2 on page 20. Refer to drawings Figure 5-1 and Figure 5-2 for connection recommendations.

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

19

Page 22

5

1 2 1 2

2 1

0vdc

2 1 2

Switch Selection Connection

MCS

Out 2

Prog

MCS

1

Out 1

Start

2

2

Prog

1

Start

2

1 SW2

PLC

TB7

SW1

MPCE

1

LCM-3XX

TB7

MPCE

LCM-3XX

PLC Selection Connection

Figure 5-1 Connection Recommendations for LCM Metal Enclosure

LCM-3

LCM-3 RET

7

PLC 7

RET

6

6 ECS 2

SW2

5

SW1

ECS 2

5

Out 1

ECS 1

4

Out 0

ECS 1

4

+24 VDC

3

+24 VDC

3

Earth

2

Earth

2

0 vdc

1

0 vdc

1

Switch Selection Connection

0vdc ref.

PLC Selection Connection

Figure 5-2 Connection Recommendations for LCM DIN Box

Switch

Switch 2

Switch 1

Pattern1

0

0

Pattern 2

0

1

Pattern 3

1

0

Pattern 4

1

1

Note: 0 = Open, 1 = Closed. Table 5-2 Switches for Multi Channel Select

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

20

Page 23

..... 5.3 F L O A T I N G B L A N K I N G Up to two channels can be disabled at any location in the detection zone without the 4700 system going to the machine stop state. The disabled channels are not fixed at a single location but “float” through the detection zone. See Table 5-3 for a diagram of 4700 system response during operation with Floating Blanking active. Table 5-3 System Response to Floating Blanking 1 1 1 1 2 2 2 2 2 2 2 Channel Channel Channel Channel Channel Channel Channel Channel Channel Channel Channel Floating Floating Floating Floating Floating Floating Floating Floating Floating Floating Floating Floating Blanking Blanking Blanking Blanking Blanking Blanking Blanking Blanking Blanking Blanking Blanking Blanking Inactive Active Active Active Active Active Active Active Active Active Active Active Channel 1 Channel 2 Channel 3 Channel 4 Channel 5... 0

1

Exception Exceptions System Response machine stop machine run

0 2 2 1 Exception Exceptions Exceptions Exceptions machine machine stop machine stop machine run run

1 Exception machine run

2 Exceptions machine run

3 3 3 2 Exceptions Exceptions Exceptions Exceptions machine machine stop machine stop machine stop run

Table 5-4 Icon Key for Tables 5-1 and 5-2 Symbol

Description

Optical channel is not blocked. Optical channel is blocked. Optical channel is selected by Exact Channel Select. Optical channel is selected by Exact Channel Select and is blocked.

5.4 U S I N G E X A C T C H A N N E L S E L E C T W I T H F L O A T I N G B L A N K I N G

! Warning! Using Exact Channel Select with Floating Blanking is an advanced feature. ▲

All situations which may occur to the 4700 system detection zone must be carefully considered. The 4700 system is less sensitive to objects in the detection zone. The safety distance must be increased. Failure to do so may cause serious injur y.

When both Exact Channel Select and Floating Blanking are selected, the floating channels are allowed to occur anywhere within the detection zone, even within the area selected by Exact Channel Select. In these areas, a channel that should normally be blocked is allowed to be clear. 5.4.1

T HE E FFECT OF E XACT C HANNEL S ELECT AND F LOATING B LANKING ON M INIMUM O BJECT R ESOLUTION

When Exact Channel Select and/or Floating Blanking is active, the safety distance is affected. Exact Channel Select and Floating Blanking desensitize the light curtain and increase the size of the minimum object detected. The increase is equal to the channel spacing distance for each channel that is disabled. • A 4700 system with 12 mm minimum object resolution and one channel disabled has a minimum object sensitivity of: R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

21

Page 24

5

12 mm + 6.25 mm = 18.25 mm (0.72 inches). • A 4700 system with 12 mm minimum object resolution and two channels disabled has a minimum object sensitivity of:

12 mm + 6.25 mm + 6.25 mm = 24.5 mm (0.96 inches). If the size of the object detected by the 4700 system increases, the minimum safe distance must increase. Use the minimum object sensitivity given in Table 5-5, Table 5-6, Table 5-7 & Table 5-8 to determine the new figure to use when computing the safety distance. Table 5-5 Sample S and Dpf Factors for 12 mm Resolution Systems Total Number of Beams Disabled by Exact Channel Select and/or Floating Blanking

Minimum Object Resolution S

Depth Penetration Factor, Dpf for use with ANSI Formula (Dpf = 3.4 (S-.276) inches)

None

12 mm (0.47 inches)

0.67 inches (16.96 mm)

1 Beam

19 mm (0.75 inches)

1.61 inches (40.93 mm)

2 Beams

26 mm (1.02 inches)

2.53 inches (64.25 mm)

3 Beams

33 mm (1.30 inches)

3.48 inches (88.43 mm)

4 Beams

40 mm (1.57 inches)

4.40 inches (111.75 mm)

5 Beams

47 mm (1.85 inches)

5.35 inches (135.93 mm)

etc... Table 5-6 Sample S and Dpf Factors for 14 mm resolution Systems Total Number of Beams Disabled by Exact Channel Select and/or Floating Blanking

Minimum Object Resolution S

Depth Penetration Factor, Dpf for use with ANSI Formula (Dpf = 3.4 (S-.276) inches)

None

14 mm (0.55 inches)

0.9 inches (24 mm)

1 Beam

25 mm (0.98 inches)

2.4 inches (61 mm)

2 Beams

36 mm (1.42 inches)

3.9 inches (99 mm)

3 Beams

47 mm (1.85 inches)

5.4 inches (136 mm)

4 Beams

58 mm (2.28 inches)

6.8 inches (173 mm)

5 Beams

69 mm (2.72 inches)

8.3 inches (211 mm)

etc... Table 5-7 Sample S and Dpf Factors for 20mm resolution Systems Total Number of Beams Disabled by Exact Channel Select and/or Floating Blanking

Minimum Object Resolution S

Depth Penetration Factor, Dpf for use with ANSI Formula (Dpf = 3.4 (S-.276) inches)

1.75 inches (44.45 mm)

None

20 mm (0.79 inches)

1 Beam

31 mm (1.22 inches)

3.21 inches (81.53 mm)

2 Beams

42 mm (1.65 inches)

4.60 inches (118.96 mm)

3 Beams

53 mm (2.09 inches)

6.16 inches (156.86 mm)

4 Beams

64 mm (2.52 inches)

7.63 inches (193.76 mm)

5 Beams

75 mm (2.95 inches)

9.1 inches (231.16 mm)

etc...

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

22

Page 25

..... Table 5-8 Sample S and Dpf Factors for 30 mm resolution Systems Total Number of Beams Disabled by Exact Channel Select and/or Floating Blanking

Minimum Object Resolution S

Depth Penetration Factor, Dpf for use with ANSI Formula (Dpf = 3.4 (S-.276) inches)

None

30 mm (1.18 inches)

3.07 inches (78.0 mm)

1 Beam

52 mm (2.05 inches)

6.03 inches (153.2 mm)

2 Beams

74 mm (2.01 inches)

8.96 inches (227.6 mm)

3 Beams

96 mm (3.78 inches)

11.91 inches (302.5 mm)

4 Beams

118 mm (4.65 inches)

14.87 inches (377.7 mm)

5 Beams

140 mm (5.51 inches)‘

17.80 inches (452.0 mm)

etc...

Hard guarding refers to mechanical barriers such as sheet or expanded metal, etc. See Figure 5-3 Adding Hard guarding to Light Curtain when Using Channel Select for an example.

Channel Select Area

Detection Zone

Floating Blanking changes the resolution (object size) of the 4700 system and will require different mounting distance.

Obstruction

Light Curtain

Light Curtain

Figure 5-3 Adding Hard guarding to Light Curtain when Using Channel Select

5.5 A C T I V A T I N G A N D P R O G R A M M I N G E X A C T C H A N N E L S E L E C T

! Warning! To prevent unauthorized modification of the sense field, the system controller ▲ should be installed in an enclosure with supervisor-controlled access.

Exact Channel Select is activated by setting position 4 of Switches A and B, located under the controller cover. Refer to Figure 3-1. Any mismatch between the settings of the switches will result in a alarm condition. To program an ECS pattern, the 4700 system must be in the machine stop state. An ECS pattern is stored by blocking the appropriate area of the detection zone and pressing, then releasing the program button (See Figure 3-4 and Figure 3-5 for locations). The MCS works the same as the ECS except in addition to blocking the appropriate area of the detection zone, an four position binary switch or PLC or two SPST switches are needed to differentiate the four possible pattern.

5.6 MCS PROGRAMING 1. Ensure that power is supplied to the controller, and that the light curtain is green and showing all beams are clear. The display should read “00”.

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

23

Page 26

5

2. Set position 4 of switches A and B to the closed position and press “Start”, the display should red “03”. 3. Set the Pattern select inputs, see Table 5-2 - Switches for Multi Channel Select. 4. Place the desired object in field (block beams) and press the “program” button, the display should read “01”. 5. Push the “start” button, and the display should read “03”. The light curtain will enter the Machine Run state. 6. To add more patterns (a total of eight possible) Set the Pattern select inputs to another program the display will read “27”, press the start button and continue to step 4. Repeat steps 4 and 5. 7. To change from one pattern to another, change the ECS inputs to the desired program and push the start button. The 4700 system will then enter the interlock or machine stop condition, regardless of the operating mode. The Start button may be pressed-and-released or power may be cycled to enter the machine run state. Subsequent power cycles will result in operation in accordance with the configured operating mode. A new ECS pattern is recorded when the system is in the machine stop state with no alarms, the configuration switches are correctly set, and the Program button is pressed and released. If the configuration switches are subsequently set to disable ECS, the stored ECS pattern is cleared. NOTE! Replace controller cover after changing system configuration. See Section 3.1.1 on page 11 and Section 3.1.2 on page 12 for details. SWITCH A 5

SWITCH B

OPERATING MODE

4

6

Exact Channel Select Active

CLOSED

CLOSED

Exact Channel Select Inactive (default setting)

OPEN /OFF

OPEN /OFF

/ON

4

5

6

/ON

One-channel Floating Blanking Active

CLOSED

OPEN /OFF

CLOSED

OPEN /OFF

Two-channel Floating Blanking Active

OPEN /OFF

CLOSED

/ON

OPEN /OFF

CLOSED

Floating Blanking Inactive (default setting)

OPEN /OFF

OPEN /OFF

OPEN /OFF

OPEN /OFF

Not Allowed – alarm Condition

CLOSED

CLOSED

CLOSED

CLOSED

/ON

/ON

/ON

/ON

/ON

/ON

/ON

Table 5-9 Switch Settings, Exact Channel Select and Floating Blanking

5.7 A C T I V A T I N G F L O A T I N G B L A N K I N G Floating Blanking (either one- or two- beam) is activated by setting positions 5 and 6 of Switches A and B located under the controller cover. Refer to . Any mismatch between the settings of Switches will result in an alarm condition. Use of the program button is not required.

5.8 A D D I T I O N A L G U A R D I N G W H E N U S I N G E X A C T C H A N N E L S E L E C T Exact Channel Select creates “holes” in the detection zone. These “holes” are required for certain applications. If an obstruction does not completely fill these “holes” one of two actions will need to happen: (Refer to Figure 5-3 Adding Hard guarding to Light Curtain when Using Channel Select). 1. The safe mounting distance will need to be increased to account for the larger opening in the curtain.

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

24

Page 27

..... 2. The area not filled by an obstruction must be guarded, typically by some method of hard guarding.

6

6 D IAGNOSTIC AND T EST F EATURES 6.1. D I A G N O S T I C D I S P L A Y

A two-digit numeric display on the front of the controller indicates system status. The table below provides the operating mode codes. A full listing of diagnostic codes can be found in Section 12 - Troubleshooting. Table 6-1 Operational Display Code Summary Display Code

Description

00

Normal Operation

01

Waiting for Start or Program Input

02

Normal Operation Floating Blanking Active

03

Normal Operation Channel Select Active

04

Normal Operation Floating Blanking and Channel Select Active

6.2 I N D I V I D U A L B E A M I N D I C A T O R S The 4700 system has a visible, red Individual Beam Indicator (IBI), adjacent to each infrared beam. These IBI’s are located on the receiver. The IBI will light when the infrared beam fails to meet the conditions necessary for the 4700 system to remain in the machine run state. IBI’s are not a safety critical component. An IBI failure will not cause an alarm condition and the 4700 system will continue to operate.

6.3 M A C H I N E P R I M A R Y C O N T R O L E L E M E N T ( M P C E ) M O N I T O R I N G MPCE monitoring is an important safety function. It monitors the 4700 system interface to the guarded machine and checks to ensure that the control elements are responding correctly to the light curtain and to detect any inconsistency between the two machine MPCE. Connections for MPCE monitoring are made at the controller on terminals 10 and 11 for the DIN controller and on TB7 terminals 1 and 2 for the metal chassis controller. For a detailed diagram, see Section 10 - Connecting To The Machine Control Circuit. On power-up, the 4700 system looks for an MPCE closed condition. If this is found, it will enter a state consistent with the selected operating mode. When the 4700 system enables its safety outputs, it monitors the MPCE for a closed-to-open transition. This transition must occur within 300 ms or the 4700 system considers the MPCE faulted. The 4700 system will then enter an alarm state. Additionally, if the MPCE connections are incorrectly wired, the 4700 will enter an alarm state.

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

25

Page 28

6

Upon entering a machine stop state, the MPCE input must close within 300 ms of the safety output switching or the system will enter the alarm state. The ability to disable MPCE monitoring is provided using the configuration switches located in the controller. NOTE! When MPCE is not active, place a jumper between the terminals MPCE and MPCE RTN for the DIN controller (or place a jumper between terminals 1 and 2 of TB7 for the Solid State Output Version of the metal chassis controller). 6.3.1

A CTIVATING AND D EACTIVATING MPCE M ONITORING

(on Din Controller and Metal Chassis Solid State Version) MPCE monitoring is activated by setting position 3 of Switches A and B located under the controller cover. Refer to Table 6-2. Any mismatch between the settings of Switches A and B will result in an alarm condition. Table 6-2 MPCE Switch Settings SWITCH A MPCE MONITORING

SWITCH B

3

3

Active

OPEN/OFF

OPEN/OFF

Not Active (default setting)

CLOSED/ON

CLOSED/ON

NOTE! Replace controller cover and retention screws after changing system configuration. See Section 3.1.1 on page 11 and Section 3.1.2 on page 12 for details. 6.3.2

A CTIVATING AND D EACTIVATING MPCE M ONITORING ON THE M ETAL C HASSIS C ONTROLLER R ELAY O UTPUT V ERSION

MPCE monitoring is activated by setting Jumper 2 in the ON position located on the main controller board of the metal chassis controllers. Position 3 of the dipswitch does not affect the operation of Relay version controller.

6.4. S T A T U S I N D I C A T O R L I G H T S The following status indicator lights are found on both the receiver and the controller. 6.4.1

S AFETY O UTPUT STATUS

When the 4700 system is in the machine run state, the green indicator LEDs on the receiver and controller illuminate, indicating that the safety outputs are ON. 6.4.2

I NTERLOCK S TATUS

When the 4700 system enters an interlock state, the yellow interlock and red LEDs on the receiver and controller are continuously illuminated. 6.4.3

A LARM S TATUS

When the 4700 system enters an alarm state, the yellow LEDs on the receiver and controller flash periodically. Additionally, a code indicating the type of fault is displayed on the two-digit diagnostic display located on the controller. Error codes are defined in Section 12 - Troubleshooting. 6.4.4

E XACT C HANNEL S ELECT AND F LOATING B LANKING S TATUS

When Exact Channel Select and/or Floating Blanking is active, the amber LEDs on the receiver and controller are illuminated.

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

26

Page 29

.....

7

7 O UTPUTS 7.1 S A F E T Y O U T P U T S 7.1.1

D IN C ONTROLLER AND M ETAL C HASSIS S OLID S TATE V ERSION

The 4700 system supplies two independent PNP-type, safety outputs to provide Run/Stop signals to the guarded machine. In the machine Run state, the safety outputs are electrically conducting and source 650 milliamps of current at 24 VDC. In the Machine Stop state, the outputs are not electrically conducting. !! WARNING! This product is designed for use on a 24 VDC, negative ground (protective ▲ ▲ earth) electrical system only. Never connect the 4700 system to a positive ground (protective earth) system. With a positive ground (protective earth) wiring scheme, certain simultaneous shorts of both safety outputs may not be detected and the guarded machine may not stop resulting is severe operator injur y.

7.1.2

M ETAL C HASSIS C ONTROLLER – R ELAY O UTPUT V ERSION

The 4700 system supplies 1 N.O. and 1 N.C/N.O. dry relay contacts, safety outputs to provide Run/Stop signals to the guarded machine. In the Run state the N.O. contacts are closed and will conduct the supplied voltage. In the Machine Stop state, the N.O. contacts are open. The N.C. contact will open in a Run state and close in a Stop state.

7.2. A U X I L I A R Y O U T P U T S 7.2.1

DIN C ONTROLLER AND M ETAL C HASSIS S OLID S TATE V ERSION

Two auxiliary outputs are provided. Auxiliary output AUX1 OUT is NPN and sinks up to 100 mA to system ground when in the on condition. Auxiliary output AUX2 OUT is PNP and sources 250 mA at 24 VDC when in the on condition. 7.2.2

METAL CHASSIS C ONTROLLER - R ELAY O UTPUT V ERSION

N.O./N.C. auxiliary outputs are provided. These outputs are intended for light curtain Status indication. The auxiliary output is user configurable for Alarm mode and Follow mode. 7.2.3

A UXILIARY O UTPUT O PERATING M ODES

The auxiliary outputs can be set to enter an ON condition either when: •The safety outputs are in the machine run state (Follow Mode), or •The 4700 system enters an alarm state (Alarm Mode). The auxiliary output operating mode is selected by setting position 7 of Switches A and B located under the controller cover. Refer to Table 7-1. Any mismatch between the settings of the switches will result in an alarm conditions.

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev.D

27

Page 30

8

Table 7-1 Auxiliary Output Operating Mode Switch Settings SWITCH A Auxiliary Output Operating Mode

SWITCH B

7

7

Auxiliary Outputs on in RUN (Follow) state

OPEN/OFF

OPEN/OFF

Auxiliary Outputs on in FAULT (Alarm) state

CLOSED/ON

CLOSED/ON

NOTE! Replace controller cover and retention screws after changing system configuration. See Section 3.1 for details.

8 S AFE M OUNTING D ISTANCE

8

! WARNING! Never install a 4700 system ▲ without regard to the safety distance. If the 4700 system is mounted too close to the point of operation hazard, the machine may not stop in time to prevent an operator injury. Light Curtain

A 4700 system must be mounted far enough from the machine danger zone so the machine will stop before a hand or other body part reaches the hazardous area. This distance is called the safety distance. It is a calculated number based on a formula. See Figure 8-1 - Safe Mounting Distance for an illustration of the safety distance.

Ds

Ds is the minimum safe distance between the light curtain sensing field and the point of operation hazard (pinch point).

Regardless of the calculated distance, a 4700 system should never be mounted closer to the point of operation hazard than allowed by Table 0-10 in OSHA 1910.217.

Figure 8-1 Safe Mounting Distance

8.1 US S A F E D I S T A N C E F O R M U L A S In the United States two formulas exist to properly determine the safety distance. STI recommends the formula provided by the American National Standards Institute (ANSI) which incorporates additional factors when compared to the formula required by OSHA. The ANSI formula given below is for a normal approach to the light curtain. Ds = K x (Ts + Tc + Tr + Tbm) + Dpf Where: Ds = minimum safety distance, in inches, between the 4700 system detection zone and the nearest point of operation hazard. K = hand speed constant in inches per second. The ANSI standard value is 63 inches/second which assumes the operator starts a hand motion toward the point of operation from rest. According to ANSI B11.19-1990, “The value of the hand speed constant, K, has been determined by various studies and although these studies indicate speeds of 63 in./sec. to over 100 in./sec., they are not considered conclusive determinations. The user should consider all factors, including the physical ability of the operator, when determining the value of K to be used.”

R

SCIENTIFIC TECHNOLOGIES INC. Fremont CA USA Tel: 1/888/510-4357 in USA and Canada

© STI 0806 PN99584-0050 Rev. D

28