Spec sheet · Microscan
Microscan MS-3 Spec Sheet
Spec sheet2 pagesPDF 176 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page specification sheet for the Microscan MS-3 Laser, an ultra-compact bar code scanner for embedded instruments, in standard and integral right angle cases. It lists the scanning, electrical, environmental and mechanical specifications, the read ranges, the supported codes and the host connector pinout.
- Device
- MS-3 Laser: ultra-compact laser bar code scanner for embedded instruments p. 1
- Scan rate
- MS-3 Laser: adjustable from 300 to 1000 scans/second, default 500 p. 2
- Read range
- MS-3 Laser: 2 to 10 in. (51 to 254 mm) p. 1
- Scan angle
- MS-3 Laser: scan width angle over 70°; pitch ±50°, skew ±40° p. 2
- Interface
- RS-232, RS-422/485 (up to 115.2k) p. 2
- Power
- MS-3 Laser: 5 VDC +/- 5 %, 200 mV p-p max. ripple, 260 mA @ 5 VDC typical p. 2
- Size and weight
- 1.75 in. (44.5 mm) square by .85 in. (21.6 mm) tall; 2 oz. (57 g) standard, 2.8 oz. (87 g) right angle p. 1, 2
- Environment
- Operating 0° to 50°C (32° to 122°F); housing IP54 (category 2); humidity up to 90% non-condensing p. 2
- Symbologies
- Code 39, Codabar, Code 128, I 2 of 5, Code 93, UPC/EAN, Pharmacode; PDF417 as an option p. 2
- Discrete I/O
- Trigger and new master inputs, 3 to 24V rated (1 mA @ 5 VDC); outputs 1, 2, 3 are 5V TTL, sink 10 mA, source 2mA p. 2
- Connector
- 3 ft. cable ending in a high density 15-pin D-Sub socket p. 2
- Protocols
- Point-to-point (plain, with RTS/CTS, with XON/XOFF, or both), Polling Mode D, multidrop, user defined, user defined multidrop, daisy chain p. 2
- Indicators
- Beeper; LEDs: 1 status, 1 power, 5 read performance p. 2
- Setup
- ESP software, or the EZ Button with no computer p. 1
What this sheet walks you through
- Host connector pin assignments for RS-232, auxiliary and RS-422/485 wiring p. 2
- Read ranges by narrow bar width, high and low density p. 2
- Mounting dimensions of the standard and integral right angle cases p. 2
- Setting up the scanner with ESP software p. 1
Good to know
- For the right angle option, subtract 0.6 in. (15 mm) from the read range. p. 2
- The chassis ground pin is only for connecting the chassis to earth ground, not for power or signal return. p. 2
- Read ranges assume the best scan speed for each symbol density. p. 2
Questions this sheet answers
How far can the Microscan MS-3 laser read?
The sheet gives a read range of 2 to 10 in. (51 to 254 mm); for the right angle option subtract 0.6 in. (15 mm). p. 1, 2
What interfaces does the MS-3 laser scanner support?
RS-232 and RS-422/485, at up to 115.2k. p. 2
How much does the MS-3 laser weigh?
The standard scanner weighs 2 oz. (57 g) and the right angle version 2.8 oz. (87 g). p. 2
Can the MS-3 read PDF417?
Yes, PDF417 is listed as an option alongside the standard linear codes. p. 2
How do I restore the MS-3 laser default configuration?
The sheet says the default is activated by connecting pin 8 to ground pin 4 on the host connector. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
MS–3 Laser
Ultra-Compact Bar Code Scanner
EZ Button Setup
The MS-3 Laser offers the fastest read performance in embedded compact bar code scanners. The wide scan angle of 70 degrees is coupled with ultra-compact size and flexible mounting.
Compact Shape/Size
Wide Scan Angle
MS–3 Laser: At a Glance
- Decodes/second: up to 1000
High performance and flexibility make the MS-3 Laser the optimal choice for reliable reading in embedded instruments. Compact & Lightweight The 1.75” (44.5 mm) square by .85” (21.6 mm) tall scanner weighs only 2 ounces (57 g) for easy mounting onto robotic equipment or into tight spaces.
- Read Range: 2 to 10” (51 to 254 mm)
- Wide Scan Angle
- IP54 Enclosure ESP®: Easy Setup Program software provides quick and easy setup and configuration of all Microscan readers. EZ Button: This performs reader setup and configuration with no computer required.
High Scan Speed Adjustable scan speed from 300 up to 1000 decodes per second and Microscan’s world-class decode algorithms ensure accurate reading every time. Wide Scan Angle The wide scan angle of over 70 degrees and a factory customizable focal point add up to space savings within your system, allowing greater flexibility with positioning.
Visible Indicators Illuminated LEDs on top of the scanner provide visual confirmation of the scanner performance. Real-time Controls The inputs include a trigger signal, a “new master” input, and a programmable input for resetting counters or releasing outputs. The outputs can be configured to activate upon a variety of conditions including matchcode and diagnostic operations. Application Examples
- Clinical instruments
- Bank ATMs
- Parking kiosks
- Point-of-sale terminals
- Robotics
For more information, visit www. smallscanners.com.
M S – 3 L a s e r : Av a i l a b l e C o d e s Linear Stacked
All Standard
PDF417
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
cm 5
MS−3 L ASER S CANNER S PECIFICATIONS AND O PTIONS Integral Case, Side
Standard Case, Sidein. 20 15 1052 1010° Laser Beam.010" .254 mm4 3.0075" .191 mm52 1Laser Beam.90" (22.9 mm).85" (21.6 mm).0033" .084 mm.005" .127 mmHIGH DENSITY SCAN AREAcm in. Range.31" (7.8 mm)1.75" (44.5 mm)cm
Standard Case, Back .85" (21.5 mm)
.45" (11.4 mm)Integral Case, Back.63" (16 mm)10in. 52.40" (61 mm)50510 502520.25" (6.3 mm)1.75" (44.5 mm)1.25" (31.7 mm)102.25" (57.2 mm)1.25" (31.8 mm).020" .508 mm
.015" 15 .381 mm .0075" .191 mm
.010" .254 mm
2X M3 x 0.5 5.3 mm depth
5 10LOW DENSITY SCAN AREA5
2X M3 x 0.5 5mm minimum depth
MECHANICAL Weight (Standard): 2 oz. (57 g) Weight (Right Angle): 2.8 oz. (87 g)
ENVIRONMENTAL Housing: IP54 (category 2) Operating temperature: 0° to 50°C (32° to 122°F) Storage temperature: –50° to 75°C (–58° to 167°F) Humidity: Up to 90% (non-condensing) Operating life: 40,000 hours at 25° C
CE MARK General immunity for light industry: EN 55024: 1998 ITE Immunity Standard Radiated and conducted emissions of ITE equipment: EN 55022:98 ITE Disturbances
LASER LIGHTcm in. Range.85" (21.6 mm).45" (11.4 mm)
HOST CONNECTOR/PIN ASSIGNMENTS High Density 15 Pin D-sub Socket Connector Pin
HostHost/AuxHostNo.RS232RS232RS422/485
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Power +5 VDC TxD TxD TxD(–) RxD RxD RxD(–) Power/Signal Ground NC Aux TxD TxD(+) RTS Output 1 TTLa Default configurationb Trigger CTS Aux RxD RxD (+) Output 3 TTLa New Master (NPN) Chassis groundc Output 2 TTLa NC
In/ Out In Out In
Out Out In In In Out In
Type: 3 ft. cable terminated with High Density 15-pin D-Sub socket connector
ELECTRICAL Power: 5 VDC +/– 5 %, 200 mV p-p max. ripple, 260 mA @ 5 VDC (typ.)
Interface: RS-232, RS-422/485 (up to 115.2k), DISCRETE I/O Keyboard Wedge, USB Trigger Input: 3 to 24V rated PROTOCOLS (1 mA @ 5 VDC) Point-to-Point • Point-to-Point w/RTS/CTS • New Master: 3 to 24V rated Point-to-Point w/XON/XOFF • Point-to-Point (1 mA @ 5 VDC) w/RTS/CTS & XON/XOFF • Polling Mode D Outputs (1, 2, 3): 5V TTL compatible,
- Multidrop • User Defined • User Defined can sink 10 mA and source 2mA Multidrop•Daisy Chain
SCANNING PARAMETERS Options: single line, fixed raster Scan rate: Adjustable from 300 to 1000 scans/second, default=500 Scan width angle: >70° Pitch: ±50° Skew: ±40° Label contrast: 25% min. @ 650 nm
Read Range HIGH DENSITY
.0033” (.084 mm) .005” (.127 mm) .0075” (.191 mm) .010” (.254 mm)
2.3” to 2.6” (58 to 66 mm) 2” to 3.1” (51 to 79 mm) 1.7” to 3.7” (43 to 94 mm) 1.5” to 4” (38 to 102 mm)
.0075” (.191 mm) .010” (.254 mm) .015” (.381 mm) .020” (.508 mm)
3” to 6” (76 to 152 mm) 2” to 7” (51 to 178 mm) 2” to 8” (51 to 203 mm) 2” to 10” (51 to 254 mm)
Note: For Right Angle option, subtract 0.6” (15 mm) from read range. Read ranges are based upon optimal scan speed for specifi c symbol density.
SAFETY CERTIFICATIONS DESIGNED FOR CDRH, FCC, UL/cUL, CE, BSMI
ISO 9001:2000 CERTIFIED QMS
OutCONNECTORCOMMUNICATIONNarrow-bar-widthLOW DENSITY
a. Can sink 10 mA and source 2 mA. b. The default is activated by connecting pin 8 to ground pin 4. c. Chassis ground: Used to connect chassis body to earth ground only. Not to be used as power or signal return.
Type: Semiconductor visible laser diode (650 nm nominal) Safety Class: CDRH Class II, 1.0 mW max.
READ RANGES
SYMBOLOGIES Code 39, Codabar, Code 128, I 2 of 5, Code 93, UPC/EAN, Pharmacode, PDF417 (option)
INDICATORS Beeper: Good read, Match/Mismatch, Noread, On/Off LEDs: 1 status, 1 power, 5 read performance (representing percentage of good decodes)
ROHS/WEEE COMPLIANT ISO CERTIFICATION Issued by RWTüV, USA Inc. ISO 9001:2000 – Cert No. 03–1212 ©2007 Microscan Systems, Inc. 07/07 Rev. B Read Range and other performance data is determined using high quality Grade A symbols per ISO/IEC 15415 and ISO/IEC 15416 in a 25°C environment. For application-specific Read Range results, testing should be performed with symbols used in the actual application. Microscan Applications Engineering is available to assist with evaluations. Results may vary depending on symbol quality. Warranty–One year limited warranty on parts and labor. Extended warranty available.
Microscan Systems, Inc. Tel 425 226 5700 / 800 251 7711 Fax 425 226 8250 Microscan Europe Tel 31 172 423360 / Fax 31 172 423366 Microscan Asia Pacific R.O. Tel 65 6846 1214 / Fax 65 6846 4641 Part of a full range of sales tools available from our website:
www.microscan.com E-mail: info@microscan.com Tech Support: helpdesk@microscan.com