Manual · Metrologic
MX001 Industrial Control Interface Installation and User's Guide
Manual50 pagesPDF 455 KB
Installation and user's guide for the Metrologic MX001 Industrial Control Interface box for TECH series industrial laser scanners.
Covers · 1 model
The models it covers
Summary
What is in it
Installation and user's guide for the Metrologic MX001 Industrial Control Interface, a box that connects an external object sensor to a Metrologic TECH series industrial laser scanner and lets the scanner switch an external device through a TRIAC. It shows how to open the box, the internal parts and LED indicators, setting 115 or 230 volt operation, wiring AC power, the TRIAC output and many kinds of sensors with or without a sensor alarm, connecting to the scanner, cable pin-outs, specifications, troubleshooting and an operational check-out procedure.
From the manual
Key facts from this manual
Each line names its page in the PDF.
Installation and user's guide for the Metrologic MX001 Industrial Control Interface, a box that links an external object sensor and a switched line-voltage output to a TECH series industrial laser scanner. It shows how to set the line voltage and fuses, wire the power input, the TRIAC output and many sensor types, connect the scanner link cable, and troubleshoot the unit.
- What it is
- Industrial control interface that adds an object sensor input and a switched line-voltage output to a TECH series laser scanner p. 7
- TRIAC output
- Up to 6 amps in the US and Canada, 5 amps in Europe; output equals line input voltage p. 7, 17
- Sensor input
- 12V, 5V, 10mA or switch closure object sensor p. 38
- Line voltage
- 115 or 230 volt, set by a voltage selector switch and the matching fuses p. 11
- Fuses, USA
- F1 TRIAC: 10 Amp 250V fast acting; F2 control: 1/8 Amp (115V) or 1/16 Amp (230V) 250V slow blow; all ¼ x 1 ¼ inch p. 11, 12
- Fuses, Europe/Asia
- F1 TRIAC: 6.3 Amp 250V fast acting, high interrupt; F2 control: 125mA (115V) or 50mA (230V) 250V time delay; all 5 x 20 mm p. 13, 14
- Scanner link cable
- Supplied, 1 meter, 8-pin male to 19-pin female Mil Spec; can be extended to 100 feet with #26 wire p. 36, 37
- Dimensions
- 152mm L x 102mm W x 76mm D (6" x 4" x 3") p. 38
- Status LEDs
- Four: green +12V (D1), red TRIAC (D2), red S IN sensor (D3), red A IN sensor alarm (D4) p. 10
- Scanner setup
- HoloSet configuration software over an RS-232 port of an IBM XT, AT or compatible PC p. 7
- Case
- Oil Tight J1C box p. 38
- Mounting
- L-bracket with the TECH scanner, or mounted on its own p. 38
- Approvals
- The manual states UL and CUL listed, CE p. 38
What this manual walks you through
- Opening and closing the control box p. 8, 36
- Setting 115 or 230 volt operation and fitting the fuses p. 11, 12, 13, 14
- Connecting the AC power input cable p. 16
- Connecting the TRIAC controlled power output cable p. 17
- Choosing a sensor type and setting the J1 and J2 jumpers p. 19, 20
- Temporarily disabling the TRIAC output or the sensor inputs p. 18, 20
- Connecting the MX001 to the scanner p. 36
- Pin outs of the 8-pin and 19-pin link cable connectors p. 37
- Troubleshooting power, fuse, TRIAC, sensor and HoloSet problems p. 39, 40, 41, 42, 43, 44
Good to know
- Shorting the TRIAC output damages the unit. p. 17
- Replace fuses only with the same type originally supplied. p. 11
- The MX001 draws no power from the scanner and must stay powered from the AC line to talk to it. p. 15
- Measuring the TRIAC output with no load connected gives a false reading; test with a 60W bulb as the load. p. 41
- A scanner programmed for sensor support scans no label, the HoloSet label included, until a sensor is connected and active. p. 44
Questions this manual answers
How much load can the MX001 TRIAC switch?
Up to 6 amps in the USA and Canada and 5 amps in Europe, at the line input voltage. p. 7, 17
What fuses does the MX001 use?
In the USA the F1 TRIAC fuse is 10 Amp fast acting and the F2 control fuse is 1/8 Amp (115V) or 1/16 Amp (230V) slow blow. Europe/Asia units use a 6.3 Amp F1 and a 125mA or 50mA time delay F2. p. 11, 12, 13, 14
How long can the MX001 scanner link cable be?
The standard cable is 3 feet (1 meter); it can be extended to 100 feet using cable with #26 wire. p. 37
Why do the MX001 sensor and TRIAC LEDs stay off while the green LED is on?
Check the scanner link cable at both ends, the internal link cable at J3, the sensor wiring and J1/J2 jumpers, and the HoloSet TRIAC programming. p. 39