The text of a manual · part 1 of 5

MX001 Industrial Control Interface Installation and User's Guide, pages 1 to 10

Pages 1 to 10 of 50

The original document is the PDF (455 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MX001

Page 1

Electronic file will be provided to printer for cover page. This page for reference only.

METROLOGIC INSTRUMENTS, INC MX001 Industrial Control Interface Installation and User’s Guide

Page 2

This page is a scan with no text; see it in the PDF.

Page 3

LOCATIONS Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683

Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Website: www.metrologic.com

Germany Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany

Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@europe.metrologic.com

Spain Metrologic Eria lbérica SL Julián Camarillo, 29 D-1 Bajo 28037 Madrid

Tel: 34-91-327 24 00 Fax: 34-91-327 38 29 Email: info@es.metrologic.com

Italy Metrologic Italia S.r.l. Via Emilia 70 1-40064 Ozzano dell’Emilia (BO)

Tel: 39-051-6511978 Fax: 39-051-6521337 Email: info@it.metrologic.com

United Kingdom Metrologic Instruments UK Limited 58 Tempus Business Centre Kingsclere Road Basingstoke Hampshire RG21 6XG

Tel: 00441256365900 Fax: 00441256365955 Email: info@uk.metrologic.com

Asia Metrologic Asia (Pte) Ltd 31 Kaki Bukit Road 3 #05-08 Techlink Singapore 417818

Tel: 65-842-7155 Fax: 65-842-7166 Email: info@sg.metrologic.com

China (only) Metro (Suzhou) Technologies Co., Ltd. 221 Xing Hai Street Suzhou Industrial Park Suzhou, China 215021

Tel: 86-512-2572511 Fax: 86-512-2571517 Email: info@cn.metrologic.com

South America Metrologic South America Rua Flórida, 1821 - 5° Andar São Paulo, SP, Brasil CEP: 04571-090

Tel: 5511-5505-6568 Fax: 5511-5505-1681 Email: info@sa.metrologic.com

Brazil (only) Metrologic do Brasil Ltda. Rua Flórida, 1821 - 5° Andar São Paulo, SP, Brasil CEP: 04571-090

Tel: 5511-5505-2396 Fax: 5511-5507-2301 Email: info@br.metrologic.com

Copyright © 1996, 2000 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

MLPN 00-02173 Printed in USA January 2001 ii

Page 4

TABLE OF CONTENTS Introduction............................................................................................... 1 Opening the MX001 Industrial Control Box .............................................. 2 Locating the Internal Components............................................................ 3 Industrial Control Box LED Status Indicators............................................ 4 Configuring the MX001 for 115 or 230 Volt Operation.............................. 5 USA: 115V Operation .......................................................................... 5 USA: 230V Operation .......................................................................... 6 Europe/Asia: 230V Operation .............................................................. 7 Europe/Asia: 115V Operation .............................................................. 8 Locating the Three Strain Reliefs and the Signal Connector .................... 9 Connecting External Wiring to the MX001................................................ 9 MX001 Power Requirement ..................................................................... 9 Connecting the AC Power Input Cable ..................................................... 10 Connecting the TRIAC Controlled Power Output Cable ........................... 11 Temporarily Disabling the TRIAC Output ................................................. 12 Sensor Support ........................................................................................ 13 Connecting the Sensor ........................................................................ 14 Temporarily Disabling the Sensor and/or Sensor Alarm...................... 14 Sensors powered independently which provide either 12V, 5V or a 10mA DC signal (sourcing type output) .................................. 15 Sensors that provide switch closures or relay type output................... 17 Low voltage self contained DC sensors with a current sinking output .................................................................................................. 18 Low voltage self contained DC sensors with a current sourcing output .................................................................................................. 19 “Universal” self contained sensors that provide a single pole/double throw (SPDT) relay output................................................ 20 Sensors powered independently which provide either 12V, 5V or a 10mA DC signal (sourcing type output with a sensor alarm)... 22 Sensors that provide switch closures or relay type output with a sensor alarm ............................................................................. 24 Low voltage self contained DC sensors with current sinking outputs and sensor alarm .................................................................... 25 Low voltage self contained DC sensors with current sourcing outputs and sensor alarm .................................................................... 26 iii

Page 5

TABLE OF CONTENTS (CONTINUED) “Universal” self contained sensors which provide single pole/double throw (SPDT) relay outputs for both object sensing and sensor alarm..................................................................................... 28 Closing the MX001 Industrial Control Box ................................................ 30 Connecting the MX001 to the Scanner..................................................... 30 Cable Pin Outs for the 8-pin and 19-pin connectors ................................. 31 Specifications ........................................................................................... 32 Troubleshooting........................................................................................ 33 No Operation – Green LED off ............................................................ 33 F2 Control Fuse Open ......................................................................... 33 No Operation Sensor & TRIAC with Green LED on (other LED’s do not light).......................................................................................... 33 No TRIAC Output with Red TRIAC LED on.............................................. 34 F1 TRIAC Fuse Open.......................................................................... 34 TRIAC Output Active with Red TRIAC LED off.................................... 35 No Sensor Input Indication (Red S in LED does not light) ................... 35 Reversed Sensor Input Indication (Red S IN LED goes off when Object is sensed)................................................................................. 36 Erratic Sensor Operation ..................................................................... 36 Continuous Sensor Input Indication (Red S IN LED continuously on) . 37 Continuous Sensor Alarm Indication (Red A IN LED continuously on) 37 Erratic Sensor Alarm Indication (Red A IN LED blinks) ....................... 38 Scanner cannot be placed in program mode using HoloSet label ....... 38 Scanner cannot be placed in program mode using HoloSet menu...... 38 Operational Check Out Procedure for the MX001 Box ............................. 39 Limited Warranty and Disclaimer.............................................................. 41 Notices ..................................................................................................... 42 Index......................................................................................................... 44 iv

Page 6

Printer note: Leave page blank

Page 7

INTRODUCTION Metrologic’s MX001 Industrial Control Interface enhances Metrologic’s line of industrial laser scanners. It does this by providing a way to connect an external object sensor to the scanner and a way for the scanner to control an external device through an electronic switch (a TRIAC). This enables the scanner to sense the presence of objects to be scanned and then provide a line voltage output signal if the scanned object meets preprogrammed conditions. The MX001 can be configured to support any object sensor that can supply a 12V, 5V or 10mA output signal. It will also support switch closure (relay) type sensor output. Additionally, the MX001 can provide 12V DC power (at 200mA maximum) to a low voltage, DC type sensor unit making external sensor power supplies unnecessary. The MX001’s electronic switch or TRIAC, allows the scanner to control an external device directly by switching a line voltage output signal off or on and can handle device loads of up to a maximum of 6 amps US and Canada, 5 amps Europe. The switching can take place in response to a good scan, a no read scan, or a mismatch between scanned label data and expected label data preprogrammed into the scanner for comparison purposes. The scanner can also activate the TRIAC switch in response to a host system command sent through the RS-232 scanner-host communications link. This manual shows how to wire and configure the MX001 Industrial Control Box so that it will work properly when connected to its associated sensor, output device and TECH series scanner. Programming the associated TECH series scanner is necessary to define how the object sensor and TRIAC switch will operate. Tech series industrial scanners are programmed by using Metrologic’s HoloSet® configuration software which operates through an RS-232 port of an IBM XT, AT or compatible PC. In order to program the scanner a HoloSet kit containing the necessary communications cable, software and manual will be needed. Please refer to that manual for further details on how to configure the scanner for use with the MX001 box.

1

Page 8

OPENING THE MX001 INDUSTRIAL CONTROL BOX To open the MX001 box for wiring and configuration, proceed as follows: 1. Loosen the lid clamp screw with a flat blade screwdriver. 2. Disengage the clamp by pushing the lid down, then move the clamp to the left, and rotate it outward in a counterclockwise direction. 3. Once the clamp is disengaged, open the lid.

2

Page 9

LOCATING THE INTERNAL COMPONENTS The following illustration and list explain the parts that pertain to the installation and operation of the MX001. 1

F2 Control

2

9

3 F1 TRIAC

J2

5

D4 C

A IN

S IN-

S in+

A In-

+12V Out

D3 C

S IN

Common

D2 C

Triac

7

A In+

Neutral

Triac out

D1 C

12V

230V

115V

Line in

10

Neutral

11

4

J1

8

6

Figure 1 1. Power Transformer

Supplies a stepped down and isolated voltage that produces the 12V DC power for the industrial control box and external sensor.

2. F2 Control Fuse Holder

Contains the fuse that controls the 12V DC power in the industrial control box.

3. F1 TRIAC Fuse Holder

Contains the fuse that controls the power for the TRIAC output.

4. Power Terminal Block

Provides the input connection point for the AC line that supplies power to the industrial control box.

(Line Power Input) 5. TRIAC Terminal Block (Controlled Power Output)

Provides the output connection point for the scanner controlled. power output (switched by the TRIAC).

6. LED Status Indicators

These light up when the +12V power supply, TRIAC, sensor, or sensor alarm circuits are active.

7. Voltage Selector Switch

Used to configure the industrial control box to match the incoming line voltage.

8. J1 Jumper

Configures sensor input.

9. J2 Jumper

Configures the sensor alarm input.

10. Sensor Terminal Block

Provides the connection points for the sensor.

11. Protective Earthing Connectors

To connect line cord protective earthing conductors to industrial control box enclosure.

3

Page 10

INDUSTRIAL CONTROL BOX LED STATUS INDICATORS The LED, (light emitting diode) status indicators are found just below the voltage selector switch. They indicate the operating state of the 12V power supply, the TRIAC and the status of the sensor and sensor alarm inputs. An LED will glow when a circuit is active. From these visual indications, it can be determined if the MX001 box is active and what action the scanner and sensor are performing in your system. The following list explains the function of each indicator. They appear inside the box in the order illustrated in Figure 2. D1

D2

D3

D4

C

C

C

C

12V

TRIAC

S IN

A IN

FIGURE 2

Green +12V (D1) Indicates that the +12V control and sensor power supply is active Red TRIAC (D2) Indicates that the TRIAC switched power output circuit is active. Red S IN (D3) Indicates that the sensor circuit is active because an object is being sensed. Red A IN (D4) Indicates that the sensor alarm circuit is active because the sensing conditions are marginal. NOTE:

4

The red TRIAC, S IN and A IN LED’s perform two functions. Besides circuit activity (status), these indicators also monitor the connection between the MX001 box and the scanner and will not light if that connection is broken. Thus, if lit, the indicators also show the user that the interconnecting signal (link) cable between the scanner and the MX001 box is good.