Manual · Intermec
Intermec 2420 and 2425 Serial Interface
Manual2 pagesPDF 44 KB
Both pages are below, each with its text.
Covers · 2 models
The models it covers
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Intermec's instruction sheet for the TRAKKER Antares 242X serial interface module, which takes the place of the scan module on a 2420 or 2425 so the terminal can connect to a PC to load firmware or to a printer for VT/ANSI terminal emulation printing. It lists the cables, firmware kits and pin assignments and walks through the connection.
- What it is
- Serial interface module that fits in place of the scan module p. 1, 2
- Uses
- Load or reload firmware, load TE or screen mapping applications, print with VT/ANSI TE p. 1
- Connector
- Stewart 10-pin serial port on the module p. 2
- Adapter cable
- RS-232 adapter cable to DB9, Part No. 061799-001 p. 1
- Null modem cables
- DB9 PC port: 5-wire 059167; DB25 PC port: 3-wire 047569 p. 1
- DB9 pins
- 2 RXD, 3 TXD, 4 DTR, 5 ground, 7 request to send; 1, 6, 8, 9 not connected p. 1
- Firmware kits
- Part No. 066814S for TCP/IP or 067119S for UDP Plus p. 1
- Related manual
- TRAKKER Antares Terminal Emulation User's Guide, Part No. 066694 p. 1
- Sheet part number
- P/N 067690-001 p. 1
What this manual walks you through
- Removing the scan module and installing the serial interface module p. 2
- Connecting the terminal to a PC or printer p. 2
- Ordering the null modem interface cable p. 1
- Ordering and using the firmware kit p. 1
- Putting the scan module back when finished p. 2
Good to know
- Do not force the module into the terminal connector; it can damage the module, the terminal or both. p. 2
- Electrostatic discharge precautions apply. p. 2
- The null modem cable, adapter cable and firmware kit are bought separately from the module. p. 1
Questions this manual answers
How do I load firmware on an Intermec 2420?
Fit the serial interface module in place of the scan module, connect it to a PC COM port with a null modem cable, and load the firmware from the PC using the firmware kit. p. 1, 2
What cable connects the 2420 serial module to a PC?
The RS-232 adapter cable 061799-001 plus a null modem cable: 059167 for a DB9 port or 047569 for a DB25 port. p. 1
Trakker Antares 2400 firmware kit part number
Part No. 066814S for TCP/IP or Part No. 067119S for UDP Plus. p. 1
Can the 2420 print to a serial printer?
Yes, with the serial interface module it can connect to a printer to use the VT/ANSI terminal emulation printing feature. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Adapter Cable DB9 Connector Pin Assignments This illustration shows the pin assignments for the DB9 connector on the adapter cable. You can use adapter cable Part No. 061799-001.
5 - Ground Not connected - 9 Not connected - 8 Request to send - 7 Not connected - 6
4 - Data terminal ready (DTR) 3 - Transmit data (TXD)
TRAKKER Antares 242X Serial Interface Module Instruction Sheet The serial interface module is an easy-to-install accessory for the TRAKKER® Antares™ 2420 and 2425 hand-held terminals. This module lets you connect the terminal to a PC and load firmware or connect the terminal to a printer to use the VT100/220/320 and ANSI (VT/ANSI) terminal emulation (TE) printing feature.
Note: Depending on the devices you are trying to connect to, you may need the RS-232 adapter cable, Part No. 061799-001.
2 - Receive data (RXD)
You can use the serial interface module to perform these tasks:
1 - Not connected 242XISI.002
Ordering the Null Modem Interface Cable You can order one of these Intermec cables to connect the adapter cable to your PC, or you can also make your own null modem interface cable. PC COM Port
Type of CablePart NumberDB9 COM port5-wire, null modem059167DB25 COM port3-wire, null modem047569•
You can install a new version of the firmware on the terminal.
You can correct problems with the current firmware by reloading it.
You can load a new TE or screen mapping application onto the terminal.
You can connect the terminal to a printer to use the VT/ANSI TE printing feature.
This instruction sheet describes how to install the serial interface module and connect the terminal to a PC or printer. For help loading the firmware, read the documentation included with the firmware kit. For help with VT/ANSI printing, refer to the TRAKKER Antares Terminal Emulation User’s Guide (Part No. 066694).
Before You Begin Make sure you have this equipment:
Ordering and Using the Firmware Kit
Serial interface module (shipped with this kit)
Contact Intermec to order a firmware kit for the TRAKKER Antares 2400 series terminals (Part No. 066814S for TCP/IP or Part No. 067119S for UDP Plus).
Optional RS-232 adapter cable, purchased separately. Contact Intermec to order an RS-232 adapter cable.
Null modem interface cable, purchased separately. For help, see “Ordering the Null Modem Interface Cable” later in this instruction sheet.
Firmware kit, purchased separately. For help, see “Ordering and Using the Firmware Kit” later in this instruction sheet.
Once you’ve installed the serial interface module and connected to a PC, you are ready to upgrade or change the firmware on the terminal. For help, see the firmware kit documentation.
6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 © 1998 Intermec All Rights Reserved P/N 067690-001
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Connecting the Terminal to a PC or Printer
Connecting the Terminal to a PC or Printer Note: Observe all electrostatic discharge (ESD) precautions.
Serial interface module Stewart 10-pin connector
1.
Power off the TRAKKER Antares 242X terminal. Lay the terminal face down on a clean and sturdy work surface.
2.
To remove the scan module from the terminal, remove the Phillips head screws and pull the scan module up and off the terminal.
3.
Unpack the serial interface module.
4.
Align the module guides on the serial interface module with the guides on the terminal. Then gently press down on the serial interface module to seat the connector guide pins and the module connector into the connector on the terminal.
Serial port DB9 connectors
RS-232 adapter cable
Note: The module guide pins and connector should fit easily into the connector on the terminal. DO NOT force the serial interface module into the connector or you may damage the module connector, the connector on the terminal, or both. 5.
Secure the serial interface module to the terminal with the Phillips head screws provided.
6.
If you are using the RS-232 adapter cable, plug the RS-232 adapter cable into the serial interface module by connecting the Stewart 10-pin connector into the serial port. Make sure the connector snaps into place.
PC COM ports
If you are using an interface cable, plug the Stewart 10-pin connector into the serial port and skip to Step 8.
Back of PC
7.
Connect the DB9 connector on the RS-232 adapter cable to the DB9 connector end of the null modem interface cable. Secure the connector mounting screws.
8.
Plug the other end of the null modem interface cable into the COM1 or COM2 port on your PC or printer. Secure the connector mounting screws.
9.
If you want to upgrade or change the firmware, use the PC to load the firmware on the terminal. For help, see the documentation included with the firmware kit.
Null modem interface cable 242XISI.001
If you want to use the VT/ANSI printing feature, send the screens or lines from the terminal to the printer. For help, see the TRAKKER Antares Terminal Emulation User’s Guide. 10. When you are finished, you can disconnect the cables, remove the serial interface module, and reinstall the scan module onto the terminal. For help, see the instruction sheet that shipped with your scan module.





