Page 1 of Intermec 2420 and 2425 Getting Started

Manual · Intermec

Intermec 2420 and 2425 Getting Started

Manual2 pagesPDF 323 KB

Both pages are below, each with its text.

Download the PDF323 KB

Covers · 2 models

The models it covers

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Intermec's two-page Getting Started Guide for the TRAKKER Antares 2420 and 2425 hand-held terminals. It describes the terminal's features and scan modules, then walks through charging and installing the batteries, first power-up, the menu system, serial port settings and setting up the radio-equipped 2425 on a 2.4 GHz network.

What it is
Programmable hand-held data collection terminals that run custom or terminal emulation applications p. 1
2420 vs 2425
T2420 uploads by RS-232 serial; T2425 adds 2.4 GHz RF to a Model 200 Controller, DCS 300 or TCP/IP host p. 1
Display
16 line by 20 character CGA-compatible screen p. 1
Keypad
56 keys, color-coded for key combinations p. 1
Memory
512K RAM for applications and a 750K flash drive; T2420 has an extended storage option p. 1
Scan modules
Standard range, long range or high density integrated laser, or a module for cabled wand, laser or CCD scanners p. 1
Battery
Rechargeable lithium-ion main pack (Intermec Part No. 063278) plus NiCad memory backup battery p. 1, 2
Charge times
Main pack about 2 hours in the charger; backup battery about 18 hours p. 2
Serial ports
COM1 via TD2400 Communications Dock or Optical Link Adapter; COM4 via RS-232 scan module adapter p. 2
Symbologies enabled
Code 39, Code 128 and UPC/EAN as shipped p. 1
Full manual
2420 and 2425 User's Manual, Part No. 064024 p. 1
Guide part number
P/N 064183-003 p. 1

What this manual walks you through

  • Charging the main battery pack p. 2
  • Connecting and charging the backup battery p. 2
  • Installing the main battery pack and battery door bumper p. 2
  • Turning on the terminal for the first time p. 2
  • Using the TRAKKER Antares 2400 Menu System p. 1
  • Typing characters with the color-coded keypad p. 1
  • Configuring the serial port p. 2
  • Installing and configuring the T2425 on a 2.4 GHz network p. 2

Good to know

  • The main battery pack must be fully charged before the terminal can be used. p. 2
  • The backup battery ships inside the terminal but is not connected. p. 2
  • A backup battery that is not fully charged gives only limited backup power. p. 2
  • If the battery door will not shut, the battery pack is not installed correctly. p. 2
  • A T2425 on a different subnet from its controller or host also needs a default router and subnet mask. p. 2

Questions this manual answers

What is the difference between the Intermec 2420 and 2425?

The T2420 uploads data over RS-232 serial; the T2425 does the same and adds 2.4 GHz radio communications. p. 1

What battery does the Intermec 2420 use?

A rechargeable lithium-ion main battery pack (Intermec Part No. 063278 is named), with a NiCad backup battery for memory and clock. p. 2

How long does the 2420 battery take to charge?

The main pack charges in about 2 hours in the charger; the backup battery takes about 18 hours. p. 2

How much memory does the Trakker Antares 2420 have?

512K of RAM for customer applications and a 750K flash drive; the T2420 has an extended storage option. p. 1

Which bar codes does the 2420 read out of the box?

It ships with Code 39, Code 128 and UPC/EAN enabled; other symbologies must be enabled first. p. 1

The file

Size and text

Pages2
PDF323 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Intermec 2420 and 2425 Getting Started

The text of page 1, from the PDF itself

Congratulations on Selecting Intermec

Bar Code Symbologies

  • Code 39
  • Code 128
  • UPC/EAN

P/N 064183-003

You use the TRAKKER Antares 2420 (T2420) terminal to collect data and periodically upload the data collected to a host computer via RS-232 serial (wired) communications.

If you are using another symbology, you need to enable it before you can scan your bar code labels.

The TRAKKER Antares 2425 (T2425) terminal has the same functionality as a T2420 with the additional ability to transmit data via radio frequency (RF) communications in Intermec’s 2.4 GHz RF network. The wireless T2425 provides real-time communications through the Model 200 Controller or DCS 300 using UDP Plus protocol or directly to a host using TCP/IP protocol.

The Main Menu appears.

Electrical Specifications T2420 and T2425

Electrical rating
xww7,2V 500mA

Both terminals have 512K of RAM reserved for customer applications and a 750K flash drive to store applications and files. The T2420 has an option for an extended storage drive.

Using the Keypad

Press the blue ( key, then the key.

The scan module for cabled scanners has a port to attach a wand, laser scanner, or CCD scanner. The standard range, long range, and high density scan modules have an integrated laser scanner.

*B022524A N TA R E SR K E K A R TF59I/OF46 83 5 27104terEEn Fn FnLJDR COILXRPcEsWQKYSMG FTNHB AVbTaU ZScan button242GSG.001

© 1998 Intermec Technologies Corporation All Rights Reserved

6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280

25SRETA9 6 83 5 72 40 1CFnO TNXRFn YSM LVJDR COILXREscWQ PYSMGKTNHBFTabVTabU ZZ5 4™L AEscWQU1EEnt JI HBP

TRAKKER Antares 2420 and 2425 Hand-Held Terminal

F3erE DRAK®

Scanner LED indicators (2 places)

L

F

The TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual (Part No. 064024) contains all the information necessary to install, configure, operate, and troubleshoot the T2420 and T2425. For information on ordering a manual, contact your local Intermec sales representative.

You can scan bar code labels with the integrated standard range, long range, or high density scan module, or with the scanning device that is connected to the module for cabled

F2

24 Fn G

Where to Find More Information

F1AN5er Ent Fn

Module for cabled scanners Standard range scan module Long range scan module High density scan module

F10BlueF5 F4 F3 F2F17

Right side above the key

3 F5 F4 F3 F2

2

Press the green ? key, then the key.

4GreenSCentered above the key6 20

Press the orange ) key, then the key.

TAOrange24

Left side above the key

2 AN

To Type the Character Press the key.

1

You can use one of these Intermec modules:

Position on the Keypad Color Middle of the key White

The TRAKKER Antares terminals are ergonomically designed to make data collection easy and include these features:

I/O

To scan bar code data, you must have a scan module installed on the terminal. A scan module is always installed at the Intermec factory.

The terminals come with a color-coded keypad to make it easier to remember key combinations.

T R A K K E R

242GSG.004

Scanning Bar Code Labels

Models
I/O

2. Press ;to choose the Configuration Menu. You can configure the network parameters or the serial port parameters using the Communications Menu. To set the time and date, use the System Menu. For help in the menu system, press !.

T R A K K E R*..-.*9*..-.*

The terminal ships with these three symbologies enabled:

The TRAKKER Antares 2420 and 2425 terminals are hand-held data collection terminals. You use these programmable terminals to run either custom applications or terminal emulation applications.

6

Enter Test and Service Mode

Getting Started Guide

3

1. Press )wwywwTwww2wwwM or ) yww2ww4ww8ww,wwor scan this bar code label to access the TRAKKER Antares 2400 Menu System.

to help meet your data collection needs. You have chosen the world leader in the data collection industry.

8

You use the TRAKKER Antares 2400 Menu System to set network or serial port parameters on the T2420 or T2425.

The terminals can decode several different types of bar code symbologies. You must configure the terminal to decode the type of bar code symbology used in your labels.

RE

Using the Menu System to Configure the Terminal

242GS.008

1

Scan module accessories for bar code data collection

2

16 line by 20 character CGA-compatible screen, angled for easy viewing

3

Keypad with 56 keys for data collection. The terminal ships with a keypad to match the application or language you ordered.

4

Serial port to support RS-232 communications

5

Rechargeable lithium-ion battery pack (shipped separately) for main power and rechargeable NiCad backup battery for memory backup

6

Adjustable antenna on the T2425 supports 2.4 GHz radio frequency communications

This Getting Started Guide shows you how to use the T2420 or T2425 and explains how to get the terminal up and running.

41

8*

Page 2 of Intermec 2420 and 2425 Getting Started

The text of page 2, from the PDF itself

Getting Started Follow these steps to get your T2420 or T2425 up and running.

1

Charging the Main Battery Pack

3

The TRAKKER Antares terminal main battery pack and power source is a lithium-ion battery. You must fully charge the main battery pack before you can use the terminal. Use the accessory battery charger to charge the main battery pack.

  • Place the battery pack in an empty slot in the battery charger. It is fully charged in about 2 hours. For help, see the documentation that came with your battery charger.

1. If the battery door is not off, open the door. 2. Hold the battery pack with the flat side facing down toward the inside of the battery compartment. The small arrow on the top of the battery pack must point toward the top (screen) end of the terminal. 3. Place the battery pack into the upper (larger) half of the battery compartment. Connector end Connector pin (2 places)

Tip: Keep a spare, charged main battery pack on hand.

2

Installing the Main Battery Pack

(2 hours)

A NiCad battery backs up all memory and the real-time clock while you change the main battery pack. The backup battery is shipped inside the T2420 and T2425, but it is not connected.

Battery wire connectors

Backup battery

242GSG.002

3. Gently fold and push the wires into the open area of the backup battery compartment near the wall. 4. Leave the battery door off to continue with the next procedure and install the main battery pack.

You must fully charge the backup battery. The main battery pack charges the backup battery when required with the terminal turned on or off. To charge the backup battery 1. Install a fully charged main battery pack. 2. Leave the terminal turned off and let the main battery pack charge the backup battery. The backup battery will be fully charged in approximately 18 hours. The main battery pack still has most of its power remaining.

5

Turning On the Terminal for the First Time

Once the batteries are charged, you are ready to turn on the terminal. To turn on the terminal 242GSG.003

4. Hook the slots on the bottom of the battery pack into the slots on the bottom of the battery compartment. 5. Slide the battery pack toward the top end of the terminal until it fits and locks into the connectors inside the bottom case. The battery pack must be all the way forward to close the battery door. 6. If you are using an Intermec-labeled battery pack (Part No. 063278), make sure you remove the rubber bumper from the inside of the battery door. If you are using a Sony-labeled battery pack, make sure the rubber bumper is installed over the ridge near the wall on the inside of the battery door. The rubber bumper on the battery door keeps the battery pack in place. 7. Hook the bottom edge of the battery door into the bottom case above the backup battery compartment. Push the door down to close it over the battery compartment. Push the battery door latch down and slide it up to lock the door in place. Note: If the battery door will not shut, the battery pack is not installed correctly. Remove the battery pack and repeat Steps 2 through 7 above to install the battery pack.

6(18 hours)Slots

To connect the backup battery

2. Find the two connectors in the backup battery compartment. One connector is attached to the backup battery. The other connector is attached to the terminal. Push the two battery wire connectors together until they lock.

Charging the Backup Battery

Note: The backup battery charges enough to operate the terminal within 20 minutes. However, the backup battery will only provide limited backup power if it is not fully charged.

Connecting the Backup Battery

1. Open the battery door by pushing down on the battery door latch and sliding it down. Lift up the top edge of the battery door to remove it.

4

1. Press the q key on the top left of the keypad. The Boot Menu appears. 2. Press wBwwto boot the terminal and initialize the firmware. The TRAKKER Antares screen appears.

Configuring the Serial Port

You use the terminal’s serial ports to transfer data between the T2420 or T2425 and a host computer in a cabled or wired network. COM1 uses a TD2400 Communications Dock or a TRAKKER Antares Optical Link Adapter and COM4 uses an RS-232 scan module adapter. You need to set these serial port parameters:

Baud rate Parity Data bits Stop bits Flow control Protocol

The values you set for the terminal’s serial port must match the values set for the host computer’s serial port.

7

Installing and Configuring the T2425

Before you can use the T2425, you need to install and configure each device in Intermec’s 2.4 GHz network: 1. In a UDP Plus network, configure the Model 200 Controller or DCS 300. For help, see the Model 200 Controller System Manual (Part No. 063439) or the DCS 300 System Manual (Part No. 067296). In a TCP/IP network, configure the host.

On a T2420 or T2425 with the programmable option, the sample application screen appears.

2. Configure the access point. For help, see your access point user’s manual.

On a T2425 loaded with a terminal emulation application, a warning screen about creating a TE configuration file may appear. Press ; to create the file and continue. An application welcome screen appears and then the T2425 tries to connect to the Model 200 Controller, DCS 300, or host. It cannot connect until you configure the RF network parameters.

3. Configure each TRAKKER Antares 2425 terminal.

3. Configure the terminal now. For help, see “Using the Menu System to Configure the Terminal” in this guide.

To configure the terminal You need to set these network parameters:

  • Time and date
  • Network activate
  • Controller IP address (UDP Plus) or host IP address (TCP/IP)
  • Terminal IP address
  • RF domain
  • RF security identification (ID)
  • Network port (TCP/IP) Note: If the T2425 is on a different IP subnetwork from the controller or host, you must also configure the default router and subnet mask.