Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Intermec Trakker Antares Optical Link Adapter Quick Reference Guide

Manual · Intermec

Intermec Trakker Antares Optical Link Adapter Quick Reference Guide

Manual2 pagesPDF 150 KB

Both pages are below, each with its text.

Download the PDF150 KB

Filed with · 2 models

Also filed with these models on the old site

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Intermec's quick reference guide for the Trakker Antares optical link adapter (Part No. 064021), an accessory for Trakker Antares terminals that passes RS-232 data between the terminal and a serial device and charges the terminal's batteries. It covers fitting and removing the adapter, the serial cables and power supply, pin assignments, specifications and troubleshooting. It refers to Trakker Antares terminals in general and does not name a model number.

What it is
Optical link adapter, Part No. 064021, for Trakker Antares terminals p. 1
Interface
9-pin RS-232 connector; 2 IR receivers and 2 IR transmitters to the terminal p. 1
Speed
RS-232 up to 38,400 bps p. 1
Serial cables
9-pin to 9-pin 5-wire null modem (Part No. 059167); 9-pin to 25-pin 3-wire null modem (Part No. 047569) p. 2
Power supply
10V jack; power supply Part No. 065236, ordered separately p. 2
Charging
Trickle charges the lithium-ion pack and NiCad backup battery, fully within 18 hours p. 1
Pin assignments
2 RXD, 3 TXD, 4 DTR, 5 GND, 7 RTS, 8 CTS p. 2
Operating temperature
-20 to 50 C (-4 to 122 F), 0 to 95% non-condensing p. 1
Charging temperature
0 to 50 C (32 to 122 F) p. 1
Storage temperature
-20 to 70 C (-4 to 158 F) p. 1
Guide part number
Part No. 065826-004 p. 1

What this manual walks you through

  • Installing the adapter on the terminal p. 2
  • Connecting the serial cable p. 2
  • Connecting the power supply p. 2
  • Transmitting and receiving data with a host, printer or modem p. 1
  • Charging the terminal batteries p. 1
  • Removing the adapter p. 2
  • Troubleshooting communications p. 1

Good to know

  • The external power supply must be connected for the adapter to charge the batteries. p. 1
  • The lithium-ion pack will not charge below 0 C (32 F). p. 1
  • Without the power supply the adapter works only if the terminal battery pack is fully charged. p. 2

Questions this manual answers

What cable connects the Trakker Antares optical link to a PC?

A 9-pin to 9-pin 5-wire null modem cable (Part No. 059167), or a 9-pin to 25-pin 3-wire null modem cable (Part No. 047569). p. 2

What power supply does the optical link adapter 064021 use?

It has a 10V jack and uses power supply Part No. 065236, ordered separately. p. 2

Optical link adapter not communicating

Check that the terminal and device baud rates match, the serial cable is correct, and there is outlet power or a fully charged battery pack. p. 1

How fast can the Trakker Antares optical link transfer data?

RS-232 baud rates up to 38,400 bps. p. 1

The file

Size and text

Pages2
PDF150 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Intermec Trakker Antares Optical Link Adapter Quick Reference Guide

The text of page 1, from the PDF itself

Charging the Terminal Batteries

Specifications

The adapter will trickle charge the lithium-ion battery pack and the NiCad backup battery. The lithium-ion battery pack and the NiCad backup battery will be fully charged within 18 hours.

Electrical requirements

S10V

Interface

9-pin, RS-232 connector

Optical interface

2 IR receivers and 2 IR transmitters

Optical RS-232 interface

Converted RS-232 bipolar signals to optical signals and vice versa

Interface speeds

RS-232 baud rate up to 38,400 bps

Operating temperature and humidity

-20qC to 50qC (-4qF to 122qF), 0 to 95%, non-condensing

Transmitting and Receiving Data

Charging temperature

0qC to 50qC (32qF to 122qF)

1. Connect the adapter to the terminal.

Storage temperature and humidity

-20qC to 70qC (-4qF to 158qF), 0 to 95%, non-condensing

Note: The external power supply must be connected to the terminal to charge the lithium-ion battery pack and the NiCad backup battery.

2. Connect the device (host computer, printer, or modem) to the adapter serial port. 3. Turn on the terminal and the device. 4. Start your program on the terminal or the device. Data begins transmitting between the terminal and the device.

Note: The terminal lithium-ion battery pack will not charge below 0qC (32qF). Design and specifications are subject to change without notice.

Quick Reference Guide

Trakker Antares Optical Link Adapter

The Trakker Antares optical link adapter (Part No. 064021) is an accessory for the Trakker Antares terminals. The optical link adapter can x

transmit data between a terminal and another serial device.

x

charge the battery pack that is in the terminal.

Troubleshooting If communications through the adapter are not working, check to make sure x

the baud rate settings for the terminal match the baud rate settings for the connected device.

x

you are using the correct serial cable.

x

there is power at the electrical outlet or you have a fully charged battery pack in the terminal.

242XOP.002

6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 © 2000 Intermec All Rights Reserved

Part No. 065826-004

Before installing and using the optical link adapter, please read these instructions thoroughly and retain them for future reference.

Page 2 of Intermec Trakker Antares Optical Link Adapter Quick Reference Guide

The text of page 2, from the PDF itself

24AN TA RE SR E K K A R TF2 F135 240ICOFnRDJEEnter1

The optical link adapter uses a 9-pin serial port for RS-232 communications. Use one of the following Intermec cables to communicate between the terminal and a device:

TYBHNSM FEsX Ta3ZUVPbKQWRLcAGFnLxx1. Press

The power supply (Part No. 065236) is ordered separately.

3

Guide post (2 places)

9-pin connector to 25-pin connector, 3-wire, null modem cable (Part No. 047569)

The optical link adapter has a 10V power supply jack for running the terminal and the adapter using an AC power source. The power supply will also charge the lithium-ion battery pack that is in the terminal.

6

2

9-pin connector to 9-pin connector, 5-wire, null modem cable (Part No. 059167)

Connecting the Power Supply to the Optical Link Adapter

3

242XOP.001

10-volt power supply jack

L to turn off the terminal.

Now you are ready to connect a communications cable and attach the power supply to the adapter. You can operate the terminal and adapter without the power supply, but the battery pack must be fully charged.

Removing the Optical Link Adapter 1. Press on the locking buttons to release the adapter latches and unlock the adapter. 2. Gently rotate the adapter downward to remove the adapter from the terminal.

En Fn Fn GLterJCOIYSMA LXRPEscWQKTNHBOptical link adapterE DRFVTabU Z

2. Insert the adapter guide posts into the locating holes on the underside of the terminal. 3. Gently rotate the adapter upward to insert the adapter latches into the slot on the back of the terminal. Push forward on the locking buttons until the buttons “snap” into place.

2F368 7

Connecting the Communications Cable to the Optical Link Adapter

0F4F5Latch (2 places)9I/O129

Installing the Optical Link Adapter 20

1

242XOP.005 242XOP.003

To the host computer or device

9-pin connector for RS-232 cable

To the power supply

The adapter serial port pin assignments are: To connect the power supply

J1 2 3 4 5 7 8

RXD (Receive data) TXD (Transmit data) DTR (Data terminal ready) GND (Signal ground) RTS (Request to send) CTS (Clear to send)

242XOP.006

To connect the serial cable 1. Connect the serial cable to the 9-pin connector located on the front of the adapter. 2. Plug the other end of the serial cable into the device serial port.

1. Attach the power supply connector to the power supply jack located on the front of the adapter. 2. Plug the power supply power cord into a powered AC wall outlet.