Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of DP1100 Installation Manual

Manual · Datalogic

DP1100 Installation Manual

Manual49 pagesPDF 621 KB

Installation manual for the Datalogic DP1100 industrial bar code decoder for one or two scan heads: wiring, interfaces and specifications.

Download the PDF621 KB

Covers · 1 model

The models it covers

Summary

What is in it

Installation manual for the Datalogic DP1100, an industrial decoder for bar code scanners available for one or two scan heads at 110 or 230 VAC. It describes the display, keypad, LEDs, removable glands panel, communication interfaces, inputs and outputs, then installation: opening the device, selecting the main serial interface, mounting, power and serial wiring (RS232, RS485 polled and non polled, 20 mA current loop), scanner and I/O connections, typical layouts, fuse replacement and technical features.

Its parts

  1. General Features
  2. Installation
  3. Maintenance
  4. Technical Features

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Installation manual for the Datalogic DP1100 bar code decoder, in its one and two scan head versions (H1 and H2) for 110 or 230 VAC. It shows how to open the unit, choose the main serial interface, wire power, serial ports, scanners, presence sensors and outputs, mount the decoder and replace its fuse. It ends with the technical features.

Read for this summary: pages 1 to 40 and 45 to 49 of 49.

Device type
Decoder for bar code scanners; connects one (H1) or two (H2) readers such as LS2100, LS4100, LS6100 or LS50 p. 8, 32
Model code
DP1100-XX00: first digit 1 or 2 scan heads, second digit 1 = 110 VAC or 2 = 230 VAC p. 9
Power supply
230 Vac or 110 Vac, 50/60Hz ± 20%; 35 VA max p. 48
Protection fuse
230 Vac version 315 mA T; 110 Vac version 500 mA T p. 46
Main interface
RS232 (factory set), RS485 polled, RS485 non polled or 20 mA current loop, chosen by jumper p. 17
Auxiliary interface
RS232; baud rates 150 to 19200 on all interfaces p. 48
Max. cable length
RS232 15 m; RS485 1200 m; 20 mA current loop 300 m p. 25, 27, 30
Scanner connector
15 pin female type D connector per scan head p. 32, 33
Display
20 character x 4 line backlit LCD p. 10
Presence sensor inputs
PS1 and PS1AUX, plus PS2 and PS2AUX on H2 models; NPN or PNP, optoisolated, 30 V and 20 mA max p. 34, 35
Sensor power
12 V typical, 50 mA max, from VDC1 and VDC2 p. 35
Outputs
Three open collector or open emitter outputs (H1: Wrong, Right, No Read; H2: Right 2, Right 1, No Read 1); 40 Vdc, 40 mA continuous, 130 mA pulsed p. 9, 38
Size and weight
240 x 200 x 66 mm; approx. 2.8 Kg p. 49
Temperature
Operating 0 to 50 °C; storage -20 to 70 °C p. 49

What this manual walks you through

  • Opening the decoder safely p. 15, 16
  • Choosing the main serial interface with the jumper block p. 17
  • Passing and wiring cables through the glands panel p. 18
  • Mounting the decoder on a wall or panel p. 21
  • Connecting AC power through the 4 pin connector p. 22
  • Wiring RS232, RS485 and 20 mA current loop host connections p. 25, 26, 27, 28, 29, 30, 31
  • Setting the multidrop address on the DIP switch for RS485 polled use p. 28, 29
  • Connecting NPN or PNP presence sensors p. 34, 35, 36, 37
  • Wiring the No Read, Right and Wrong outputs p. 38, 39
  • Replacing the protection fuse p. 46

Good to know

  • Disconnect the power supply before opening the decoder or changing the fuse. p. 16
  • Install the decoder on a power source with an on/off switch or breaker within reach of the operator. p. 7
  • Ground the cable shield at one point only, to avoid noise and damage to the drivers. p. 24
  • If the connected reader works above 35 ºC, the manual advises using the Beam Shutter. p. 49
  • A code longer than the LCD is not fully shown, though it is fully sent to the host. p. 10

Questions this manual answers

What fuse does the DP1100 use?

The 230 Vac version takes a 315 mA T fuse and the 110 Vac version a 500 mA T fuse; the decoder must be opened to change it. p. 46

How do I switch the DP1100 from RS232 to RS485?

Open the decoder and move the jumper block to the RS485 polled or non polled position; RS232 is the factory setting. p. 17

How do I enter keypad programming on the DP1100?

Press the Up-arrow and ENT keys at the same time. p. 10

Which scanners work with the DP1100 decoder?

The manual names the LS2100, LS4100, LS6100 and LS50; H1 models take one reader and H2 models two. p. 32

What does the DP1100 model number mean?

In DP1100-XX00 the first digit gives the number of scan heads (1 or 2) and the second the supply voltage (1 = 110 VAC, 2 = 230 VAC). p. 9

The whole text · 5 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 4941-49

The file

Revision and size

Revision821000002 (Rev. B)
PublisherDatalogic S.p.A.
Pages49
PDF621 KB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 49

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 49
Page 2
Page 2of 49
Page 3
Page 3of 49

More documents · 1

For the same models