Page 31
DP1100
DATALOGIC
DP1100
USER INTERFACE +
9
C.L. OUT+
8
C.L. OUT+
7
C.L. IN+
6
C.L. IN-
MAXIMUM LENGTH: 300 m
Figure 2.20 - 20 mA C.L. passive connections
To select this interface type, follow the instructions in paragraph 2.3.1 "Main Serial Interface Selection".
2.7
AUXILIARY RS232 INTERFACE CONNECTIONS
The auxiliary serial interface is used exclusively for RS232 point to point connections. The parameters relative to the auxiliary interface (baud rate, data bits, etc.) as well as particular operating modes such as local echo can be defined using the Winhost utility program or Keyboard Mode programming or Host Mode programming. For more details refer to the section "Auxiliary Interface Menu" in the Help On Line of the Winhost utility program.
2.18 - Installation
Page 32
DATALOGIC
DP1100
The terminals of the external cable must be connected to the following pins of connector J1 (see figure 2.10) to connect the RS232 auxiliary interface: RS232 auxiliary connection Pin
Name
Function
11 12 13 14 10
RXAUX CTSAUX RTSAUX TXAUX SGND
Auxiliary Input Auxiliary Handshake Auxiliary Handshake Auxiliary Output Signal Ground
DP1100
USER INTERFACE 11 RXAUX
TXD
14 TXAUX 12 CTSAUX 13 RTSAUX 10 SGND
RXD DTR DCD SGND
MAXIMUM LENGTH: 15 m RTS/CTS HARDWARE HANDSHAKING ENABLED
Figure 2.21 - RS232 auxiliary interface connections
The RTSAUX and CTSAUX signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the DP1100 activates the RTSAUX output to indicate a message is to be transmitted. The receiving unit activates the CTSAUX input to enable the transmission.
2.8
BARCODE READER CONNECTIONS
The DP1100 can be connected to one (H1 models) or two (H2 models) barcode readers such as LS2100, LS4100, LS6100 or LS50 through the 15 pin connector(s) illustrated in figure 2.22.
Installation - 2.19
Page 33
DP1100
DATALOGIC
Figure 2.22 - 15 pin female connector type D
The following pins are available:
Barcode reader connector pinout Pin
Name
Function
1
GND
Ground
2
VDC
Operating Voltage
3
- VIDEO
Complementary Video Signal
4
+ VIDEO
Video Signal Representing Code
5
+ SCAN
Scan Start
6
- SCAN
Complementary Scan Start
7
N.C.
Not Connected
8
N.C.
Not Connected
9
I.U.
Internal Use
10
I.U.
Internal Use
11
CODE
Good Read Signal
*12
I.U.
Internal Use
13
RESOL
Resolution Signal
14
BS
Beam Shutter (Laser Off Signal)
15
N.C.
Not Connected
* For H1 models only this is the PCS (Print Contrast Signal) for connection to an LS4100 barcode reader.
2.20 - Installation
Page 34
DATALOGIC
2.9
DP1100
I/O CONNECTIONS
2.9.1
Inputs
PS1 and PS1AUX presence sensor inputs refer to scan head 1, while PS2 and PS2AUX presence sensor inputs refer to scan head 2 (H2 models only). For more details refer to paragraph 1.3.7. The signals relative to these sensors must be connected to the decoder via the proper internal connectors J2, J3 and J4 (see figure 2.10), respecting the following connections: Connector J2 Pin
Name
Function
*1 *2 *3 *4
PS2+ PS2VDC2 GND2
Presence Sensor 2 (+) Presence Sensor 2 (-) PS2 Operating Voltage PS2 Signal Ground Connector J3
Pin
Name
Function
1 2 3 4
PS1+ PS1VDC1 GND1
Presence Sensor 1 (+) Presence Sensor 1 (-) PS1 Operating Voltage PS1Signal Ground Connector J4
Pin
Name
Function
*7 *8 *9 *10 11 12 13 14
PS2AUX+ PS2AUXGND2 VDC2 PS1AUX+ PS1AUXGND1 VDC1
Auxiliary Presence Sensor 2(+) Auxiliary Presence Sensor 2 (-) PS2 Signal Ground PS2 Operating Voltage Auxiliary Presence Sensor 1(+) Auxiliary Presence Sensor 1 (-) PS1 Signal Ground PS1 Operating Voltage
* H2 models only Installation - 2.21
Page 35
DP1100
DATALOGIC
A PRESENCE SENSOR input can be driven by sensors with NPN or PNP output and is optoisolated to assure maximum disturbance immunity. The electrical features are: maximum voltage applicable at input: 30 V. maximum current: 20 mA. VDC1 and VDC2 and their relative ground references (GND1, GND2) supply power to the presence sensor from DP1100 with the following characteristics: typical voltage: 12 V. maximum current: 50 mA. A debounce filter is present on both inputs: the nominal value of the delay is 5 ms. PRESENCE SENSOR
DP1100
J3 or
(J2)
V+
3
VDC
1
PS+
2
PS-
Signal
4
GND
Ground
CONNECTION WITH NPN SENSOR
DP1100
PRESENCE SENSOR 3
VDC
V+ or
1
PS+
Signal
(J2)
2
PS-
4
GND
J3
Ground
CONNECTION WITH PNP SENSOR
PS+ = PS1+ or (PS2+) PS- = PS1- or (PS2-) VDC = VDC1 or (VDC2) GND = GND1 or (GND2) Figure 2.23 - Presence sensor input connections
2.22 - Installation
Page 36
DATALOGIC
DP1100
For H2 models, when 2 scanners are connected to DP1100 in a Single Reading layout, the presence sensors inputs should be connected in parallel to a single NPN sensor. These connections are provided in the following figure. DP1100
J3
J2
PRESENCE SENSOR v+
3
VDC1
1
PS1+
2
PS1-
Signal
4
GND1
Ground
3
VDC2
1
PS2+
2
PS2-
4
GND2
PARALLEL CONNECTION WITH NPN SENSOR Figure 2.24 - Connection for Single Reading with 2 scanners
For the device configuration refer to the section "Reading Mode" in the Help On Line of the Winhost utility program.
Installation - 2.23
Page 37
DP1100
DATALOGIC
AUXILIARY PRESENCE SENSOR
DP1100
J4
14, (10)
VDC
11, (7)
PSAUX+
12, (8)
PSAUX-
Signal
13, (9)
GND
Ground
V+
CONNECTION WITH NPN SENSOR
AUXILIARY PRESENCE SENSOR
DP1100
J4
14, (10)
VDC
V+
11, (7)
PSAUX+
Signal
12, (8)
PSAUX-
13, (9)
GND
Ground
CONNECTION WITH PNP SENSOR
PSAUX+ = PS1AUX+ or (PS2AUX+) PSAUX- = PS1AUX- or (PS2AUX-) VDC = VDC1 or (VDC2) GND = GND1 or (GND2) Figure 2.25 - Auxiliary input connections
2.24 - Installation
Page 38
DATALOGIC
2.9.2
DP1100
Outputs
The following pins are present on connector J4 (see figure 2.10) of the decoder depending on the model: Connector J4 for H1 models Pin
Name
Function
1 2 3 4 5 6
WRONG+ WRONGRIGHT+ RIGHTNO READ+ NO READ-
Wrong Read Output (+) Wrong Read Output (-) Right Read Output (+) Right Read Output (-) No Read Output (+) No Read Output (-)
Connector J4 for H2 models Pin
Name
Function
1 2 3 4 5 6
RIGHT2+ RIGHT2RIGHT1+ RIGHT1NO READ1+ NO READ1-
Right Read Output (+) for scan head 2 Right Read Output (-) for scan head 2 Right Read Output (+) for scan head 1 Right Read Output (-) for scan head 1 No Read Output (+) for scan head 1 No Read Output (-) for scan head 1
The electrical features are: VCE max.
40 Vdc
Collector current max.
40 mA continuous; 130 mA pulsed
VCE saturation
1V at 10 mA
Installation - 2.25
Page 39
DP1100
DATALOGIC
DP1100
USER INTERFACE Vext
1,3,5
SIGNAL+
2,4,6 SIGNAL-
Figure 2.26 - Open collector output connection
DP1100
USER INTERFACE Vext 1,3,5
SIGNAL+
2,4,6 SIGNAL-
Figure 2.27 - Open emitter output connection
In the figures above, SIGNAL+ and SIGNAL- are used to refer to the corresponding No Read, Right or Wrong output signals, see table on the previous page. For the description of the DP1100 outputs refer to paragraph 1.3.8. These outputs are both level or pulse programmable: a 50 ms pulse is generated in the second case. Further programming information is supplied in the section "Output Lines" in the Help On Line of the Winhost utility program.
2.26 - Installation
Page 40
DATALOGIC
2.10
DP1100
TYPICAL LAYOUTS
The DP1100 decoder was specifically designed for industrial applications. A typical use is real time identification of moving objects on conveyors. The decoder generally activates the scanner(s) when signalled by a photoelectric sensor used as a code presence sensor when an object enters the barcode reader reading zone. See the following figures for example layouts depending on whether H1 or H2 models are used.
Host
DP1100
PS
LS4100
Figure 2.28 - DP1100 (H1) typical application
Host
DP1100
LS4100
PS
LS4100 Figure 2.29 - DP1100 (H2) with 2 scanners in single reading mode
Installation - 2.27