For the Datalogic DP-1100

Page 41

DP1100

DATALOGIC

Host

DP1100

LS4100 PS

LS4100

Figure 2.30 - DP1100 (H2) with 2 scanners in single reading mode

Host

DP1100

LS4100

PS

LS4100

Figure 2.31- DP1100 (H2) with 2 scanners in single reading mode

2.28 - Installation

Page 42

DATALOGIC

DP1100

Host

DP1100

PS LS4100 PS LS4100

Figure 2.32 - DP1100 (H2) with 2 scanners in twin reading mode

2.10.1 Pass Through Pass Through mode allows two or more DP1100s to be connected to a single external serial interface by chaining the Auxiliary and Main interfaces towards the Host. Each DP1100 transmits the messages received by the Auxiliary interface onto the Main interface. All messages will be passed through this chain to the host. Both H1 and H2 models can be used in this layout, however H2 models must be used in Twin Reading Mode, see figure 2.32. See the WinHost Help OnLine for software configuration details. The reading phase of each DP1100 is independent from the others in Pass Through mode. Connections for a Pass Through layout are shown in the following figure:

Installation - 2.29

Page 43

DP1100

DATALOGIC

DP1100

DP1100 LS4100

LS4100

1 2 3

3

1 1

Main serial interface

2

Auxiliary serial interface

3

Presence sensor

HOST

Figure 2.33 - Pass through layout

2.10.2 Local Echo For H1 models, in local echo mode data is transmitted on the auxiliary interface as well as on the main interface. Host Mode programming can be accomplished either through the main interface or the auxiliary interface in local echo mode. DP1100 LS4100

1

Main serial interface

2

Auxiliary serial interface

3

Presence sensor

1

3

2 HOST 2 (optional)

HOST 1

Figure 2.34 - Local echo layout

2.30 - Installation

Page 44

DATALOGIC

DP1100

2.10.3 Master-Slave (Special software versions only) Upon request, special versions of the DP1100 can implement a Master-Slave layout for data collection from several scanners to build a multi-sided reading system. There can be one Master and up to 9 Slaves connected together. The Slave decoders are connected to the main and auxiliary serial interfaces using RS232 only. Each Slave DP1100 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the Master. The Master decoder is connected to the Host on the main serial interface. The possible main interface types for the Master decoder are RS232 or RS485. For details see the the WINHOST Help On Line. The P.S. signal is unique to the system; there is a single reading phase and a single message from the Master decoder to the Host PC. DP1100 Slave

DP1100 Master

LS4100

3 1

1

3

2

LS4100

1 Main serial interface HOST

2 Auxiliary serial interface 3 Presence sensor

Figure 2.35 - Master-slave layout

Both H1 and H2 models can be connected in the Master-Slave layout.

Installation - 2.31

Page 45

DP1100

DATALOGIC

This page is intentionally left blank.

2.32 - Installation

Page 46

DATALOGIC

3

DP1100

MAINTENANCE

!

3.1

REPLACING THE PROTECTION FUSE

All the internal circuits of the DP1100 are protected by a fuse on the input power line. The decoder must be opened to change the fuse.

WARNING The decoder must be disconnected from the power supply during this operation.

Refer to paragraph 2.3 to open the decoder. To replace the protection fuse refer to the following instructions: 1) Unscrew the screw on the protection shield indicated in figure 3.1, paying attention to the cable which is connected to the electrical ground. 2) Remove the protection shield. 3) Replace the fuse whose position is shown in figure 3.2. Make sure to use the correct value as specified in the protection fuse table below.

PROTECTION FUSE 230 Vac version

315 mA T

110 Vac version

500 mA T

Maintenance - 3.1

Page 47

DP1100

DATALOGIC

PROTECTION SHIELD GROUND CABLE SCREW

Figure 3.1 - Protection shield position

PROTECTION FUSE Figure 3.2 - Fuse position

3.2 - Maintenance

Page 48

DATALOGIC

4

DP1100

TECHNICAL FEATURES DP1100 H1

DP1100 H2

ELECTRICAL FEATURES INPUT POWER Supply voltage

230 Vac 50/60Hz ± 20% (184-276V)

Supply voltage

110 Vac 50/60Hz ± 20% (88-132V)

Power consumption max.

35 VA

SERIAL INTERFACES MAIN

RS232, RS485 Non Polled, RS485 Polled, 20 mA C. L.

AUXILIARY

RS232

BAUD RATES All Interfaces

150 to 19200

CONTROL INPUTS (optocoupled NPN or PNP)

1 presence sensor

2 presence sensors

1 auxiliary presence sensor

2 auxiliary presence sensors

Voltage max.

30 Vdc

Input current max.

20 mA

CONTROL OUTPUTS (open emitter open collector)

VCE max. Collector current max. VCE saturation

No Read1

No Read

Right Read1

Right Read

Right Read2

Wrong Read 40 Vdc

40 mA continuous; 130 mA pulsed 1V at 10 mA

USER INTERFACE LED indicators power on, data reception, data transmission, presence sensor active, barcode decoded

Technical Features - 4.1

Page 49

DP1100

DATALOGIC

SOFTWARE FEATURES READABLE CODE SYMBOLOGIES Up to 22 readable barcode symbologies including: • • • •

Interleaved 2/5 Code 39 (Standard and Full ASCII) Codabar Code 93 (Standard and Full ASCII)

• • •

EAN/UPC (including Add-on 2 and Add-on 5) Code 128 EAN 128

CODE SELECTION up to six codes during one reading phase

CODE POSITION can be verified and displayed if necessary

DECODING SAFETY HEADERS AND TERMINATORS can enable multiple good reads of same code up to four headers and four terminators

OPERATING MODES on line, automatic, serial on line, test

CONFIGURATION MODES

• • •

PARAMETER STORAGE through menus using WINHOST utility through KEYBOARD MODE receiving commands from one of the serial ports (HOST MODE) Non-volatile internal EEPROM

ENVIRONMENTAL FEATURES Operating temperature (see Note)

0 to 50 °C

Storage temperature

-20 to 70 °C

Humidity max.

90% non condensing

Vibration resistance

IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis IEC 68-2-27 test EA 30G; 11 ms; 3 shocks on each axis

Shock resistance

PHYSICAL FEATURES Mechanical dimensions

240 x 200 x 66 mm

Weight approx. 2.8 Kg.

NOTE If the barcode reader connected to the DP1100 is used in high temperature environments (over 35 ºC), the use of the Beam Shutter is advised (see "Beam Shutter" in the "Reading Parameters" section of the Winhost utility program). 4.2 - Technical Features