Page 11

DP1100

1.3.3

DATALOGIC

LEDs

The 7 colored LEDs on the DP1100 front panel are shown in the following figure: 1 EXT TRIG

2 GOOD READ

EXT TRIG

GOOD READ

TX DATA

RX DATA

POWER ON

Figure 1.1 - DP1100 LEDs

The first two LEDs refer to scan head 1 connected to the decoder. The next two LEDs refer to scan head 2 for H2 models. The LEDs indicate: EXT TRIG

YELLOW LED indicates the code presence sensor is active (for details refer to the section "On Line Mode" in the Help On Line of the Winhost utility program).

GOOD READ

RED LED is used to signal successful barcode decoding. It is also used in Test mode to signal the decoding (for details refer to the section "LED Threshold" in the Help On Line of the Winhost utility program).

TX DATA

GREEN LED indicates transmission of data relative to the code or to programming running on the main serial interface.

RX DATA

GREEN LED indicates reception of data relative to the code or to programming running on the main serial interface.

POWER ON

RED LED indicates the decoder is powered.

1.3.4

On/off Switch

The on/off switch can be used to turn the device off if an emergency on the system occurs. The device can also be turned off for working on the internal cabling or other particular maintenance.

1.4 - General features

Page 12

DATALOGIC

1.3.5

DP1100

Removable Glands Panel

To make installation and replacement easier, the DP1100 is made up of two parts: 1) the body of the device with all standard electronic components and optional boards 2) the removable panel housing the glands for all external communication cables This panel houses four glands for I/O and serial interface connections.

1.3.6

Communication Interfaces

The DP1100 is equipped with the following serial communication types for its main serial interface: EIA RS232

EIA RS485 NON POLLED

EIA RS485 POLLED

20 mA CURRENT LOOP

The DP1100 also supports an RS232 auxiliary interface to be connected to another host computer or for particular layouts such as Pass Through. Details regarding the connections and use of the interfaces are given in chapter 2 "Installation".

1.3.7

Inputs

PS1 presence sensor inputs (and PS2 for H2 models), allow code reading and consequent decoding to be synchronized with an external sensor, as in On Line operating mode. During the PRESENCE SENSOR active phase, the yellow LED on the front of DP1100 is activated and VIDEO and SCAN signals for decoding are acquired from the scanner. PS1AUX (and PS2AUX for H2 models) are auxiliary presence sensor inputs used to indicate to the decoder what code to store as the verifier code. For further details refer to the section "Store Verifier HW" in the Winhost Help On Line. General features - 1.5

Page 13

DP1100

1.3.8

DATALOGIC

Outputs

Three outputs are present to signal if the barcode reading has been performed or not. They have different meanings depending on the model used. H1 models: •

NO READ output

•

RIGHT output

•

WRONG output (Code Verifier and PCS)

The NO READ output activates when the code signalled by the presence sensor is not decoded. The RIGHT output activates when the code is decoded correctly. The WRONG output is used either in Code Verifier or PCS modes. See Winhost Help On Line. H2 models: •

NO READ 1 output for scan head 1

•

RIGHT 1 output for scan head 1

•

RIGHT 2 output for scan head 2 (Code Verifier only)

The NO READ output activates when the code signalled by the presence sensor is not decoded. The RIGHT output activates when the code is decoded correctly.

For further details on these outputs, refer to the relative sections in the Winhost Help On Line.

1.6 - General features

Page 14

DATALOGIC

2

DP1100

INSTALLATION

2.1 PACKAGE CONTENTS Verify that the DP1100 reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: 1) DP1100 decoder 2) Installation manual 3) DP1100 configuration program disk 4) Terminal block connectors 5) Power supply connector

4 1

3

5 2 Figure 2.1 - DP1100 package contents

2.2 GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the DP1100 decoder.

Installation – 2.1

Page 15

DP1100

DATALOGIC

1) Open the decoder to select the main serial interface type as required (see paragraph 2.3). 2) Provide correct system cabling according to the signals necessary (see par. 2.5, the applicable sub-paragraphs under 2.6, par. 2.7, 2.8, and 2.9). 3) Install the Configuration Disk and configure the software parameters from a host computer using one of the following methods: • WINHOST interface utility program. For more details refer to the section “DP1100 Configuration” in the WINHOST Help On Line. • Host Mode programming procedure by ESC sequences via the serial interface. For more details refer to the Word document hdp1100.doc in the DP1100 directory. • Keyboard Mode through the keypad and the display. For more details refer to the Word document kdp1100.doc in the DP1100 directory.

NOTE Fine tuning of the scanner position for barcode reading can be accomplished using the Test Mode. For further details refer to the section "Test Mode" in the Help On Line of the Winhost utility program.

The installation is now complete.

!

2.3

OPENING THE DEVICE

Before installing the DP1100 it may be necessary to open it to perform the following operations: •

Select the required main serial interface. (Par. 2.3.1)

•

Set the multiplexer address selection on the DIP switch. (Par. 2.6 under "RS485 Polled Interface")

•

Change cable connections on the glands panel. (Par. 2.3.2)

2.2 - Installation

Page 16

DATALOGIC

•

DP1100

Mount the decoder on a panel or a wall. (Par. 2.4)

You have to remove the top panel to perform all these operations; you also have to remove the glands panel to change cable connections.

WARNING The decoder must be disconnected from the power supply during this operation.

Refer to the following instructions and diagram below when opening the decoder: 1) Turn the DP1100 off. 2) Disconnect the power supply cable. 3) Unscrew the four screws as shown below to open the decoder. 4) Carefully remove the cover of the decoder while paying attention to the cable that is connected to the electrical ground; this cable is long enough to allow you to lay the cover to the side while operating inside the device.

Figure 2.2 - Opening the DP1100

Installation – 2.3

Page 17

DP1100

!

DATALOGIC

2.3.1 Main serial interface selection

One of the following interface types can be selected to connect the main interface of the DP1100 to the host computer: EIA RS232 EIA RS485 POLLED

20 mA CURRENT LOOP EIA RS485 NON POLLED

To select the interface type, position the jumper block as indicated in the following figure:

SW1

SW1

SW2 SW3

SW2

SW3

RS232

20 mA C.L.

RS485 POLLED RS485 NON POLLED

Figure 2.3 - Interface type selection

NOTE The RS232 interface type is factory set.

2.4 - Installation

Page 18

DATALOGIC

!

DP1100

2.3.2 Removing and wiring the glands panel

After opening the decoder you must remove the panel housing the glands to connect or change the internal cabling to the DP1100. To connect an external cable to the DP1100, proceed as follows: 1)

Turn the DP1100 off.

2)

Disconnect the power supply cable.

3)

Open the DP1100 as described in paragraph 2.3.

4)

Using a screwdriver, unlock the screws that fix the glands panel and remove it from the DP1100 body.

5)

Unscrew the glands and pass the cables through them.

6)

Cut the insulation of the cable on the DP1100 side by a few centimeters.

7)

Strip the individual wires by a few millimeters.

8)

Loosen the terminal block connector screw of the selected position, insert the wire and tighten the screw (see figure 2.4).

9)

After inserting all the wires in the terminal block connectors, pass them through the glands panel hole and insert them into the base again (see figures 2.5 and 2.6).

10) Affix the glands panel to the DP1100 body with the proper screws adjusting the cables to the proper length through each gland and then tightening the glands.

Installation – 2.5

Page 19

DP1100

DATALOGIC

Figure 2.4 - Inserting the wire

Figure 2.5 - DP1100 view

Figure 2.6 - Terminal block connector and base

2.6 - Installation

Page 20

DATALOGIC

DP1100

2.4 MECHANICAL INSTALLATION 2.4.1 Overall Dimensions The figure below gives the overall dimensions of the decoder and its relative mounting holes and may be used for its installation.

mm in

Figure 2.7- Overall dimensions

Installation – 2.7