SaveTime & Savetime Lite Setup and Test

Manual41 pagesPDF 181 KB

Setup and test guide for the CMI SaveTime and SaveTime Lite data collection terminals: self-diagnostics, Off line Mode and setup.

Download the PDF181 KB

Covers · 1 model

The models it covers

Summary

What is in it

Control Module's setup and test guide for the SaveTime and SaveTime Lite data collection terminals. It explains the self-diagnostics the terminal runs at power-up and the messages shown when they pass or fail, then how to enter Off line Mode and use Setup Mode to set baud rate, parity, host delay, terminal address and reader type, by scanning an INIT label or with the keyboard. It also covers Quick Check, Diagnostics, Utilities, clearing RAM, and wiring and testing reader and Wiegand modules.

From the manual

Key facts from this manual

Each line names its page in the PDF.

The Control Module Inc. (CMI) setup and test guide for the SaveTime and SaveTime Lite data collection terminals; its pages carry the heading 2015 / 2016. It explains Off line mode, setting the communication and reader parameters by INIT label or keypad, the modem, badge, bar code and Ethernet utilities, the self-diagnostics messages, the quick checks, the network and automatic tests, and clearing RAM.

Read for this summary: pages 1 to 18 and 25 to 34 of 41.

Device
Wall-mounted CMI data collection terminal with keypad, display and a wand or slot reader p. 3, 7
Serial settings
Baud rate 1200, 2400, 4800, 9600 or 19200; parity odd, even, mark, space or none; host delay 0 to 9 (1 to 90 mS); address 00 to 31 p. 10
Data format
10 bits: one start bit, seven data bits, one parity bit, one stop bit p. 10
Reader types
Barcode, Mag I, Mag II, Wiegand, Holonetic, each of Barcode, Mag 1, Mag 2 and Wiegand paired with Holonetic, or Bioscan p. 10
Factory settings
19200 baud, odd parity, host delay 0 (1 mS, cluster mode), address 00, bar code reader p. 10
Network size
Up to 32 terminals per network, each with its own address from 00 to 31 p. 10
Setup memory
Parameters kept in NOVRAM through power off and through Clear RAM p. 10, 34
Low voltage alarms
LOW LINE between 6.7VDC and 8.7VDC; BATTERY FAIL below 6.7VDC p. 25
Self-diagnostics
Checks CPU, ROM, RAM, FLASH, NOVRAM, RTC and, in Off line mode only, the communication interface, at each power up p. 3
Failure messages
CPU MEM FAILED; BANK 1 FAILED, BANK 2 FAILED or BANK 1 & 2 FAILED; NOVRAM FAILED; SETUP REQUIRED !!; RTC FAILED p. 6
Ethernet
Through a LINC module: terminal IP and port, subnet mask or host bits, gateway, host IP and port, TCP or UDP mode, set from the keypad p. 16, 17, 18
Displays
Pages headed 2015 / 2016 with 2x20, 2x24, 2X40 or 4x20 displays p. 3
Magnetic badges
Track 1 and track 2 typically supported (see the reader label) p. 29

What this manual walks you through

  • Putting the terminal into Off line mode p. 7, 26
  • Setting all parameters by scanning an INIT label p. 11
  • Changing baud rate, parity, delay, address and reader type from the keypad p. 12
  • Checking and initializing the modem p. 13
  • Reading the bits of a Wiegand or proximity badge and decoding bar code badges p. 14, 15
  • Setting the Ethernet addresses of the LINC module, including host bits p. 16, 17, 18
  • Monitoring the supply voltage in Quick-Check mode p. 25
  • Checking the display, beeper, communication circuitry, keyboard, wand and slot reader p. 26, 27, 28, 29
  • Running the network test and the automatic test p. 30, 31, 32, 33
  • Clearing all data and download from RAM p. 34

Good to know

  • Remove power before removing or inserting the 052 module, and remove an A052 module while setting the LINC module. p. 16
  • An external reader in the LINC wand monitor port blocks communications if pin 1 is grounded in the reader; unplug it during setup. p. 16
  • Older LINC modules cannot be detected from the setup menu and must be changed with Telnet or the serial wand cable. p. 16
  • The network test is only for RS485 terminals connected to the CMI RS232 to RS485 adapter, CMI modem module or CMI Network module. p. 30
  • Clear RAM erases all data and download; the setup parameters are kept. p. 34

Questions this manual answers

How do I get a SaveTime terminal into setup mode?

On a SaveTime, move the On-Line / Off-Line switch on the COM module to Off-Line; on a SaveTime Lite, hold the C and E keys while powering up. p. 26

What are the default communication settings of a CMI SaveTime terminal?

19200 baud, odd parity, host delay 0 (1 mS, cluster mode), address 00, with a bar code reader. Usually only the address needs changing. p. 10

What does LOW LINE mean on the display?

The supply voltage has dropped to between 6.7VDC and 8.7VDC; below 6.7VDC the display shows BATTERY FAIL. p. 25

How many terminals can share one network?

Up to 32, each with a unique address from 00 to 31. p. 10

How do I clear the terminal's memory?

Choose CLEAR RAM? in Off line mode and confirm twice; data and download are lost but setup parameters stay in NOVRAM. p. 34

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Revisions page41

From the PDF’s own bookmarks.

The whole text · 5 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9
  2. Pages 10 to 1810-18
  3. Pages 19 to 2719-27
  4. Pages 28 to 3628-36
  5. Pages 37 to 4137-41

The file

Revision and size

RevisionRevision 1.0, June 1, 2001
PublisherControl Module, Inc.
Pages41
PDF181 KB