The text of a manual · part 5 of 5
SaveTime & Savetime Lite Setup and Test, pages 37 to 41
Pages 37 to 41 of 41
The original document is the PDF (181 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the CMI SaveTime Series 2000
Page 37
2043-014 LED DEFINITION
RXD
A
TXD
CH1
F
POWER
B
E
LINC
C
D
STAT
A) RXD - Receive data from Host to CMI terminal. B) TXD - Transmit data from the CMI terminal to the host C) CH1 – Channel status. ON – not blinking = Host not connected to LINC module. ON – blinking = Host Connected to LINC module. D) STAT – Status LED. OFF – not blinking = LINC module is OK, no defects. ON – not Blinking = network failure. CH1 is used for failure codes 4x = Network connection is faulty. This code only appears after power up. ON – blinking = diagnostic failure. CH1 is used for failure codes: 1x = Eprom checksum error 2x = RAM error 3x = Network controller error (Toke n Ring) 4x = EEprom checksum error or bad 5x = IP address already used on network. E) LINC – Valid Network Connection. F) POWER – ON when power is applied. Under Normal operation not connected to host the following LEDS are on : Power, LINC, CH1 Under Normal operation, connected to host the following LEDS are on : Power, LINC, CH1(flashing) If the host is communicating with the CMI terminal, RXD and TXD will blink If the LINC has a problem the STAT led will be flashing If the LINC has a network problem, the STAT will be On.
2043_014 LINC LED STATUS
3:04 PM
Page 38
Index:
Index A Addressing ( terminal identifier) Alarm Input
B Baud Rate Setup Barcode Barcode Analysis, testing your badges on the terminal Barcode types supported BIOS ( Prom software) Entering the BIOS setup BioScan Bioscan Utilites in offline mode Testing the reader Firmware Version Setup Configuration
C Clear Ram (punches and download script only) Communications RS232 Modem Ethernet, Token Ring RF Contacting Control Module Incorporated (CMI)
D Diagnostics mode Digital Input Wiring the 2052 Aux module and the Voltage Limits Digital Output Wiring the 2052 Aux module and the Voltage Limits
E Ethernet Module Configuring with Telnet Configuring with the SaveTime Terminal in offline mode
F Failure Messages Flash Firmware
Page 39
Index:
G H Holonetic Testing badges in Setup Mode Host Delay
I Initialization Labels, Configuring the Terminal ID Utilities
J K L LED information LINC module Setup, See Ethernet Module Loader Mode
M Magnetic Testing Badges in Setup Mode Modem Module ( 2400 and 9600 baud) Testing the module
N,O Network Module, See Ethernet Module Network Test ( RS485)
P Parity settings Proximity Testing badges in Setup mode
Q Q.C.M (Quick Check Mode) ‘Q’ in the display of the Terminal
R Ready Mode ( Dumb Terminal Mode) Relay Output Wiring the 2052 AUX module and the Voltage Limits RF terminals Configuring the terminal in Setup mode RS485 module Network Test.
Page 40
Index:
S Setup Mode ( Getting to the offline mode) SaveTime Product Line SaveTime Lite Product Line Self Diagnostics
T Table of Contents Testing the terminal in the offline mode
U Utility Mode
V Version Information
W Wands Barcode wands as a source of input Wiegand Input Module Wiring the 2052 AUX module Wiegand Output Module Wiring the 2052 AUX module Wiegand Analysis Testing badges in Setup mode.
X,Y,Z
Page 41
Revisions Click an item to view update Version 1.0 (Alpha Release) 06/01/01 Version 1.0 (Alpha Release) 06/ 28/01 Added ID Utilities to Utilities Menu
TR2016_Setup_Revisions Property of Control Module, Inc 1 of 1 Do not distribute or duplicate without written permission from Control Module, Inc
Page