Page 28
2016 Setup Mode Diagnostics / 3.5
Practice Using the Keyboard, Wand, or Slot Reader As mentioned earlier, when a terminal is in the Quick-Check mode, it is disconnected from the network. So you can use this mode to become comfortable with the keyboard, wand, or slot reader without affecting the rest of the system. You can also use this procedure to read bar code or check its quality. If you need tips on using the keyboard, wand, or slot reader, refer to the Appendixes. When you use this procedure, it is assumed that the terminal's keypad is on (this value was assigned to the terminal when it was shipped). See “Using the Setup Mode” for more information. To enter the Quick-Check mode, follow these steps: For Savetime Light, Hold down the C and E keys while powering up the terminal. For Savetime, locate the On-Line / Off-Line switch on your COM module and place it in Off-Line mode. The terminal will show SETUP MODE .. Press the ↑↓ arrows until the display shows: QUICK CHECK?
↑↓ E H
Press the E key to enter QCM mode. 2. Press any keys, scan bar codes, or read badges. Under “QUICK CHECK ,” the display shows the keys pressed or the character(s) in the bar code. Notes: Keys and bar code with only one character-----When you press keys or scan several single-character bar codes in a row, the characters scroll from the right in the display. The display holds up to 20 characters or more. When you try to enter too many characters, the: Terminal beeps, Display flashes “TOO MANY CHARS,” and then re-displays “QUICK CHECK ” If this happens, just continue to press more keys or scan more bar codes until you are ready to the next step. Bar codes with more than one character-----Each time you scan a multi-character bar code or read badges, the display overwrites any previous characters you entered. 3.
Press CLEAR key to erase, one at a time, each character you entered from the keyboard.
Note: Before you can go to the next step, you must erase from the display any character(s) you entered. If you press the CLEAR key after all characters are erased, you will go to the Setup mode. (Refer to “Using the Setup Mode” for your next step.) 4.
Do one of the following:
Perform another operation in the Quick-Check mode-----Go to the procedure, in this section, you want to follow. Use another mode or Off line in the Off line mode-----Refer to the section describing the mode or test you want to use. Exit the Off line mode-----Move On line / Off line switch to the On line position.
Control Module Inc.
2016 Setup Diagnostics
Page 29
2016 Setup Mode Diagnostics / 3.6
Troubleshooting Following are some suggestions to use if any of the basic functions fail or do not work as you might expect. If Display or Communication Circuitry Fails... If the display or communication circuitry malfunctions, contact your service center for further assistance. If Beeper, Keyboard, Wand, or Slot Reader Fails... If the beeper, keyboard, wand, or slot reader malfunctions, refer to Table 6-1 before contacting CMI's Service Department for further assistance. Beeper: Check the beeper-----Is there any obstruction near the beeper hole? Keyboard: Vary your technique-----Are you pressing the center of the keys? Check the overlay-----If present, is it located properly on the keyboard? Wand: Check the input device jack-----Is the wand plugged in securely? Clean the tip of the wand-----Carefully remove any dust or debris with a soft cloth. Vary your scanning technique-----Refer to the Appendixes for tips on using the wand. Check the tip of the wand-----Visible red wands emit a red light. Check the quality of the bar code-----Scan another bar code that has been read successfully. If the bar code is worn by too many scans or has spots, smears, or gaps, it will be difficult to read or unreadable. Verify that the terminal is set up to read this type of bar code-----Most terminals read Code 39 bar code in the Quick-Check mode. If you cannot read a bar code, try reading a Code 39 bar code (there is one on the back of the terminal). Slot Reader: Check the operation of the slot reader-----Optical slot readers (visible) emit a red light. Clean the slot reader-----Carefully remove any dust or debris with a cleaning badge. Use an optical cleaning badge for an optical slot reader or a magnetic cleaning badge for a magnetic slot reader. Vary your technique-----Refer to the Appendixes for tips on using the slot reader. Check the quality of the badge-----It should not be cracked or worn. The bar code should be ½ inch up from the bottom with plenty of white space on both sides. If the bar code is too dense, it will not read. If you have an Infared reader, (You can not see the LED in the reader if this is true), your badge must have a minimum amount of carbon content in the ink. If you have a magnetic reader, try your credit card. There are 3 tracks to a magnetic badge. CMI typically supports track 1 and track 2. ( See the reader label) Check the type of badge-----Use bar code badges for an optical slot reader or magnetic Track II badges for the magnetic slot reader. If you have a Proximity or Wiegand badge, use the Wiegand analysis. If you have a BIOSCAN reader, use the Biometric Utilities.
Control Module Inc.
2016 Setup Diagnostics
Page 30
2016 Setup Mode Diagnostics / 3.7
Running the Network Test Use this test when you are installing terminals or troubleshooting and want to check the network communication lines from a terminal to the host computer. (Note this is for RS485 terminals only connected to the CMI RS232 to RS485 adapter, CMI modem module or CMI Network module.) This test is performed in two stages: at the terminal and at the communication adapter. Starting the Test To start the test: 1. To enter the Quick-Check mode, follow these steps: For Savetime Light, Hold down the C and E keys while powering up the terminal. For Savetime, locate the On-Line / Off-Line switch on your COM module and place it in Off-Line mode. The terminal will show SETUP MODE Setup Mode? INIT 19,O,HDØ,AØØ,BC
↑↓ E
Q
.. Press the ↑↓ arrows until the display shows: DIAGNOSTICS
↑↓ E H
.. Press E and use the ↑↓ arrows until the display shows: DIAGNOSTICS NETWORK TEST
↑↓ E H
2. Start the test-----Press E key. Note: At this time, move the Test/Use switch on the communication adapter at the (host computer) to the Test position. or Skip to the next test, the Automatic Test-----Press CLEAR key. (Refer to “Running the Automatic Test” for your next step.) 3. The display shows: DIAGNOSTICS SWITCH TO USE
↑↓ E H
4. Start the test-----Move the On line / Off line switch to the On line position on the COM module The display shows either: NET PASSED
5.
NET FAILED
The display shows: ENTER TO RETEST
6. Do one of the following: Repeat this test-----Press the E key; then go to step 3. Control Module Inc.
2016 Setup Diagnostics
Page 31
2016 Setup Mode Diagnostics / 3.8 Exit the Off line mode-----Move On line / Off line switch to the Off line position then back to the On line position. Note: Before you finish this procedure, move the Test/Use switch on the communication adapter so it is the Use position.
Control Module Inc.
2016 Setup Diagnostics
Page 32
2016 Setup Mode Diagnostics / 3.9
Running the Automatic Test Use this test when you are troubleshooting and want to check these parts of the terminal: Programmable read-only memory (PROM) Random-access memory (RAM) Communication circuitry Real-time clock (RTC) Display The Automatic Test continuously cycles the terminal's parts until you stop the test. If a part fails the test, the display flashes the failed message; then the test automatically continues to check the next part. As each part is being tested, there is a two to four second pause before a passed or failed message appears.
Starting the Test: To start the test: 1. To enter the Quick-Check mode, follow these steps: For Savetime Light, Hold down the C and E keys while powering up the terminal. For Savetime, locate the On-Line / Off-Line switch on your COM module and place it in Off-Line mode. The terminal will show SETUP MODE ↑↓ E
Setup Mode? INIT 19,O,HDØ,AØØ,BC
Q
.. Press the ↑↓ arrows until the display shows: ↑↓ E H
DIAGNOSTICS
.. Press E and use the ↑↓ arrows until the display shows: ↑↓ E H
DIAGNOSTICS AUTO TEST? Start the test-----Press E key. The display shows either : RAM PASSED
RAM FAILED
Communication Circuitry The display shows either: COMM PASSED
COMM FAILED
RTC (REAL TIME CLOCK) The display shows either: RTC PASSED
RTC FAILED
Control Module Inc.
2016 Setup Diagnostics
Page 33
2016 Setup Mode Diagnostics / 3.10
Display: If the test is successful, these characters scroll in the display: !"#$%&'()*+'_-/Ø 123456789:;< Ø 123456789:;<=>? !"#$%&'()*+ or If the test fails, one of the following occurs: The display is blank. All or part of a segment, number, or letter is not lit. Send the terminal to your service center for repair. If the test was successful, you will see this message to test again: DIAGNOSTICS AUTO TEST?
Control Module Inc.
↑↓ E H
2016 Setup Diagnostics
Page 34
2016 Setup Mode Diagnostics / 3.11 Using the Restart Mode Beginning Restart: Use the Restart mode when you want to clear all data from a terminal's random-access memory (RAM) because there is: Corrupted data or other data you do not want to keep We designed Restart so that you have two chances to decide if you want to clear the terminal's RAM before it happens. Note: When you use Restart, the parameters entered in the Setup mode are not lost because they are stored in NOVRAM To start the test: To enter the Quick-Check mode, follow these steps: For Savetime Light, Hold down the C and E keys while powering up the terminal. For Savetime, locate the On-Line / Off-Line switch on your COM module and place it in Off-Line mode. The terminal will show SETUP MODE Setup Mode? INIT 19,O,HDØ,AØØ,BC
↑↓ E
Q
.. Press the ↑↓ arrows until the display shows: ↑↓ E H
CLEAR RAM?
.. Press E to begin or H to exit. DATA AND DOWNLOAD WILL BE LOST
EH
.. Press E to begin or H to exit. CLEAR RAM Are you sure?
EH
.. Press E to begin or H to exit. ( Last Chance) RAM CLEARED
Note: At this point, the terminal restarts so it performs self-diagnostics. (Refer to “Self-diagnostics,” for more information.) If you leave the On line/ Off linee switch in the Off line position, the terminal returns to the beginning of the Off line mode. (Refer to “Introducing the Off line Mode” for more information.)
Control Module Inc.
2016 Setup Diagnostics
Page 35
2016 Loader Mode / 4.1
Loader Mode Setup During the power up phase when the COM module switch in the Off-Line mode, you can hold the ‘C’ key. This will bring you to the Loader mode. 1.
To enter the Loader mode, press the E key Setup? ↑↓ E
2.
This allows you to setup the baud rate for Loader mode only. Use the arrows keys to change baud rate and move between the options. (192ØØ is the default) BAUD ← → 192ØØ ↑ ↓
3. Once the parity is setup, use the left and right arrows to move to the next item ( ODD is default) PARITY ← → ODD ↑ ↓
4. Once the terminal type is setup, use the left and right arrows to move to the next item ( J is default) TYPE ← → J ↑↓ 5. Once the terminal type is setup, use the left and right arrows to move to the next item (Ø is default) ADDR ← → Ø ↑↓ 6. Once the delay is setup, use the left and right arrows to move to the next item (DØ is default) DELAY ← → DØ ↑ ↓ 7. Your are done with Setup mode. Setup? ↑↓ E
Control Module Inc.
2016 Loader Mode
Page 36
2016 Loader Mode / 4.2
Utility Mode During the power up phase when the COM module switch in in Off-Line mode, you can hold the ‘C’ key. This will bring you to the Loader mode. 3.
To enter the Loader mode, press the ↑ ↓ arrows until Utils is on the display then press the E key Utils? ↑↓ E
4.
This allows you to setup mode the terminal will be in. If you have an application loaded and you change the mode to Loader, your application will not function until you go back to APP mode. This assumes you have an Application loaded. Press the E key to enter Loader mode. Mode? ↑ Loader E
APP mode: Press the ↑ ↓ arrows until APP is on the display then press the E key Mode? ↑ APP E This is the mode you use to run the flash application and your download.