Page 19

2016 Setup Utility Mode / 2.7

Using the Utilities Mode: Use ↑↓ to view the Utilities, press ENTERto enter a specific utility, press HOMEfor the setup menu. RF UTILITIES ↑↓ E H

UTILITIES RF Utilities ? Press ENTERto enter the Utility RF UTILITIES Reading LINC Module

The terminal will then attempt to read the LINC module If a control module P/N 2052-xxx is installed, the LINC module will not be found. If certain readers are connected to the LINC wand/monitor port the LINC will not be found. Remove the module or reader and connect the keypad/display into the 2043 and try again. RF SETTING CHANGED

You should see the message above if the LINC module is found. #CE ↑ ↓←

Terminal IP

→H

Enter the IP address of this LINC module. Terminal Port

→H

#CE ↑ ↓←

The port should stay at 3001. Subnet Mask

→H

#CE ↑ ↓←

Enter the sub-net mask. Your host PC must and the LINC must match. Gateway IP →H

#CE ↑ ↓←

If you are using a gateway, enter it here. See you IT person if you do not Know if you require one. Unit Name

→H

#CE ↑ ↓←

Enter a name for the LINC module. 14 bytes used to identify a specific access card. It is not critical to match the access point unit name to communicate with the LINC. ESS ID

→H

#CE ↑ ↓←

Your ESS ID must match what is in the access point. Alpha characters can be entered with up and down arrows. Right arrow advances to next position when entering data. IF the ESS ID does not match the access point, you will not be able to communicate with the LINC. Control Module Inc.

2016 Setup Utilities

Page 20

2016 Setup Utility Mode / 2.8 Update RF Linc ?

EC

To update the LINC module with these changes, press ENTER. To disregard the changes, press CLEAR, RF Setup reference information (System Summary from access point)

ESS id in this case is CMI_PILOT

Control Module Inc.

2016 Setup Utilities

Page 21

2016 Setup Utility Mode / 2.9

Using the Utilities Mode: Use ↑↓ to view the Utilities, press ENTERto enter a specific utility, press HOMEfor the setup menu. Biometric Utilities Firmware Version ↑↓ E H

UTILITIES Biometric Utilities Press E to enter the Utility

Use the Up and down arrows to select a menu item. BIO UTILITIES Firmware Info?

↑↓ E H

Press E to enter the Utility Two windows will appear. First the Firmware in the BIO reader BIO UTILITIES PS ØØ276C

↑↓ E H

Then the Setup information for the BIO reader.

K3.0_061 is the Kernel , A4.30_06 is the Algorithm used. BIO UTILITIES K3.Ø_Ø61 A4.3 Ø_Ø6

↑↓ E H

You will be returned to the Biometric Utiliites menu.

Control Module Inc.

2016 Setup Utilities

Page 22

2016 Setup Utility Mode / 2.10 Biometric Utilities -continued BIOSCAN test Use the Up and down arrows to select BIOSCAN test. BIO UTILITIES BIOSCAN test?

↑↓ E H

Press E to enter the Utility Follow the terminal directions to test the BIOSCAN reader. Put finger on sensor

Remove finger

Finger enrolled

Put finger on sensor

Remove finger

Finger Verified

This tests the BIOSCAN sensor. If you do not get these results, the sensor may be damaged . Verify you can get the firmware version to indicate the link between the terminal and reader are ok.

Control Module Inc.

2016 Setup Utilities

Page 23

2016 Setup Utility Mode / 2.11 Biometric Utilities -continued SETUP info Use the Up and down arrows to select BIOSCAN test. BIO UTILITIES SETUP info?

↑↓ E H

Press E to enter the Utility The information breaks down to be the following: 5Ø Quality Setting. This should never be below 4Ø . 5Ø Content Setting. This should never be changed. 3 Security Setting. This should be 3. 5 Max templates per ID ( 1Ø is the Max) 1ØØØ Minimum time between barcodes. (Default is 1ØØØ ) 2ØØ Message length (Default is 2ØØ ) BIO UTILITIES 5Ø 5Ø 3 5 1 ØØØ 2ØØ

↑↓ E H

Control Module Inc.

2016 Setup Utilities

Page 24

2016 Setup Utility Mode / 2.12

Using the Utilities Mode: Use ↑↓ to view the Utilities, press ENTERto enter a specific utility, press HOMEfor the setup menu. ID Utilities ↑↓ E H

UTILITIES ID Utilities Press E to view the Options.

Serial Number Use the Up and down arrows to select a menu item. ↑↓ E H

ID UTILITIES Serial Number? Press E to view the Serial Number.

CMI Service Info Use the Up and down arrows to select a menu item. ↑↓ E H

ID UTILITIES CMI Service Info?

Press E to view the Service Information.

CMI Warranty Info Use the Up and down arrows to select a menu item. ID UTILITIES CMI Warrenty Info?

↑↓ E H

Press E to view the Warrenty Information.

Control Module Inc.

2016 Setup Utilities

Page 25

2016 Setup Mode Diagnostics / 3.2 Monitoring the Voltage of a Terminal During the Quick-Check mode, a terminal continuously monitors its supply voltage. This function is extremely helpful for multi-dropped installations where power is shared among several terminals. If a terminal is installed at the end of a power line, its voltage may be marginal because of the drop across the line. 1. To enter the Quick-Check mode, press CLEAR key until the terminal displays this message and sounds its beeper for one second: Q.C.M.

2. When the voltage drops to between 6.7VDC and 8.7VDC, the terminal immediately displays this message: LOW LINE

3. When power is restored to operate the terminal, the display shows: LINE RECOVERED

Note: If the message above does not appear within a few minutes, contact your service technician or electrical contractor to check the voltage at the terminal. 4. When the voltage drops to less than 6.7VDC, the display shows: BATTERY FAIL

Check whether the battery is properly installed in the terminal. Run self-diagnostics (refer to “Self-diagnostics”). If the failure message appears again, recharge the battery. 5. Do one of the following: Perform another operation in the Quick-Check mode-----Go to the procedure, in this section, you want to follow. Use another mode or Test in the Off line mode-----Refer to the section describing the mode or test you want to use. Exit the Off line mode-----Move On line / Off line switch to the On line position.

Control Module Inc.

2016 Setup Diagnostics

Page 26

2016 Setup Mode Diagnostics / 3.3

Checking the Basic Functions of a Terminal Follow the steps below when you want to check a terminal's: Display Beeper Communication circuitry Keyboard Wand Slot reader When you use this procedure, it is assumed that the terminal's keypad is on (this value was assigned to the terminal when it was shipped). See “Using the Setup Mode” for more information. To enter the Quick-Check mode, follow these steps: For Savetime Light, Hold down the C and E keys while powering up the terminal. For Savetime, locate the On-Line / Off-Line switch on your COM module and place it in Off-Line mode. The terminal will show SETUP MODE.. Press the ↑↓ arrows until the display shows: Q.C.M.

Display and Beeper Display and Beeper To check the display and beeper, press any numeric keys or scan bar codes. To the right of “Q.C.M.,” the display shows the keys pressed or the character(s) in the bar code. Check the display-----Are all characters of uniform intensity? Are entire characters lit? Check the beeper-----Is the tone of the beeper clear and uniform? Does the terminal beep each time you press a key or read bar code successfully?

Communication Circuitry Communication Circuitry The communication circuitry is tested after each keyboard or bar code entry. A keyboard entry is one or more keystrokes or one or more single-character bar codes followed by an Enter key or Enter label. A bar code entry occurs when a multi-character bar code is read. To test the communication circuitry, do one of the following: After pressing keys or scanning single-character bar codes-----Press ENTER key. After scanning multi-character bar codes-----Go to step 4. (The test is run automatically.) or Exit the Quick-Check mode-----Press CLEAR key to erase, one at a time, all the characters you entered. Go to step 6. If the communication circuitry test passes, the display remains the same. Or If the test fails, the display shows: COMM FAILED

Note:

Refer to “Troubleshooting,” in this section, for your next step.

Control Module Inc.

2016 Setup Diagnostics

Page 27

2016 Setup Mode Diagnostics / 3.4

Keyboard, Wand, or Slot Reader Keyboard, Wand, or Slot Reader To check the keyboard, wand, or slot reader, press keys, scan bar codes, or read badges and note the following: Keys and bar code with only one character-----When you press keys or scan several singlecharacter bar codes in a row, the characters scroll from the right to the left in the display. The display holds up to 16 characters. When you try to enter the 17th character, the: Terminal beeps, Display flashes “TOO MANY CHARS,” and then re-displays “Q.C.M .” If this happens, just continue to press more keys or scan more bar codes until you are ready to go to the next step. Bar codes with more than one character-----Each time you scan a multi-character bar code or read a badge, the display overwrites any previous characters you entered. Check the keyboard-----Do any keys stick? Does the correct key appear in the display? When you hold a key down, does it repeat in the display? Do any keys seem to operate intermittently? Check the wand or slot reader-----Does it read bar code correctly? Does it have a good read rate; that is, a high percentage of reads per scan? Do one of the following: Go to the Setup mode-----Press CLEAR key. (Refer to “Using the Setup Mode” for your next step.) Exit the Off line mode-----Move On line / Off line switch to the On line position

Control Module Inc.

2016 Setup Diagnostics